I-SepaFlash™ HP Series
Amakholomu e-flash ochungechunge lwe-HP ane-spin-welded futhi avumela ukucindezela okuphezulu okungafika ku-400 psi. I-adaptha etholakalayo isiza ukuhambisana nanoma iyiphi isistimu ye-flash emakethe. Lolu chungechunge luhlinzeka ngokuguquguquka kwe-Luer-Lok in kanye ne-Luer-Lok out ukuze kube lula ukupakisha ikholomu. Uma ipakishwe ngaphambili ngejeli ye-silica esebenza kahle kakhulu (engajwayelekile, 25-40 μm, 60 Å; eyindilinga, 20-45 μm, 70 Å), lolu chungechunge lunikeza ukulungiswa okuvelele phezu kwama-flash cartridges avamile.
※ Khetha ngokukhululekile i-silica engajwayelekile noma i-silica eyindilinga ngokuya ngokuthanda kwakho
※ Ukulungiswa okuthuthuke ngokuphawulekayo kanye nekhono eliphezulu lokulayisha isampula
※ I-silica eyindilinga inikeza ukusebenza okuthuthukisiwe ngaphandle kokukhulisa ukucindezela kwesistimu
Ngejeli ye-silica eyindilinga, izilawuli zekhwalithi eziqinile ukusuka kokungavuthiwe kuya kumkhiqizo oqediwe ziqinisekisa ukukhiqizwa kabusha kwe-lot-to-lot ephezulu kanye nokucaciswa okulawulwa ngokuqinile.
※ Ukungaguquguquki, ukwethembeka, ukukhiqiza kabusha
※ Akukho ukungcola, i-backpressure ephansi
※ ukulungiswa okuphezulu
※ Iziqongo ezilinganayo ezingenawo umsila
※ Isampula ephezulu yokulayisha umthamo
I-silica engasebenzi kahle kakhulu, 25−40 µm, 60 Å(indawo engaphezulu 500 m2/g, pH 6.5–7.5, umthamo wokulayisha 0.1–15%)
Inombolo Yento | Usayizi Wekholomu | Usayizi Wesampula(g) | Izinga lokugeleza(mL/min) | Ubude beCartridge (cm) | I-Cartridge ID (mm) | Ubukhulu. Ingcindezi(psi/bar) | Inani ngeBhokisi ngalinye | |
Encane | Okukhulu | |||||||
SW-5102-004 | 4g | 4mg-0.6g | 15–30 | 113.8 | 12.4 | 400/27.5 | 24 | 120 |
I-SW-5102-012 | 12g | 12mg-1.8g | 25–50 | 134.8 | 21.4 | 400/27.5 | 24 | 108 |
SW-5102-025 | 25g | 25mg-3.8g | 25–50 | 184 | 21.4 | 400/27.5 | 18 | 72 |
SW-5102-040 | 40g | 40mg-6.0g | 30–60 | 184.4 | 26.7 | 400/27.5 | 12 | 48 |
SW-5102-080 | 80g | 80mg-12g | 40–80 | 257.4 | 31.2 | 350/24.0 | 10 | 20 |
I-SW-5102-120 | 120g | 120mg-18g | 45–90 | 261.5 | 38.6 | 300/20.7 | 8 | 16 |
I-SW-5102-220 | 220g | 220mg-33g | 60–120 | 223.5 | 61.4 | 300/20.7 | 4 | 8 |
SW-5102-330 | 330g | 330mg-50g | 60–120 | 280.2 | 61.4 | 250/17.2 | 3 | 6 |
SW-5102-800 | 800g | 800mg-120g | 50-100 | 382.9 | 78.2 | 100/6.9 | 3 | - |
SW-5102-1600 | 1600g | 1.6g-240g | 50-100 | 432.4 | 103.8 | 100/6.9 | 2 | - |
SW-5102-3000 | 3kg | 3g-450g | 50-100 | 509.5 | 127.5 | 100/6.9 | 1 | - |
SW-5102-5000 | 5kg | 5g-750g | 50-100 | 770 | 127.5 | 100/6.9 | 1 | - |
I-SW-5102-010K | 10kg | 10-1.5 kg | 50-100 | 850 | 172.5 | 100/6.9 | 1 | - |
※ Iyahambisana nazo zonke izinhlelo ze-flash chromatography emakethe.
Ukuhlanzwa kwezinhlanganisela okunzima ukuzihlukanisa nge-flash chromatography (ΔRf ≤ 0.2 phakathi kwamachashazi ku-TLC) kuvame ukuphumela ezinyathelweni ezengeziwe ezifana nokuhlanzwa okulandelayo ngesikali sokulungiselela i-HPLC. Kungenzeka ukunciphisa inani lomsebenzi owengeziwe odingekayo ukuze kuhlanzwe ngokumane unqwabelene amakholomu amaningana asepakishwe kusengaphambili e-SepaFlash™ ekugcineni aphele ohlelweni lwe-flash chromatography.
Ku-chromatography ewuketshezi, izinhlobo zamakhemikhali ziyahlukaniswa ngesisekelo sokuhluka kwazo ngesivinini njengoba zihamba phakathi kwekholomu. Ukwandisa ubude bekholomu kungakhuphula kakhulu ukulungiswa. Ngokupakisha amakholomu ekupheleni kobude kuya kububanzi (L kuya ku-D) isilinganiso siyakhuphuka ukuze kungabikho izinguquko ezinkulu kumidiya nesistimu ye-solvent edingekayo. Ngokuvamile lokhu kukhuphuka kuka-L kuya ku-D kwanele ukunikeza ukuhlukaniswa okuphumelelayo kwezingxube ezinzima ngenxa yokuvala isikhathi sokugcinwa kwezinhlanganisela ezingatholakali kukholamu eyodwa. Idatha ibonisa ubudlelwano bomugqa phakathi kokulungiswa kanye nobude bekholomu iyonke.
I-UltraPure spherical silica, 40−75 µm, 70 Å(indawo engaphezulu 500 m2/g, pH 6.0–8.0, umthamo wokulayisha 0.1–10%)
Inombolo Yento | Usayizi Wekholomu | Usayizi Wesampula(g) | Izinga lokugeleza(mL/min) | Ubude beCartridge (cm) | I-Cartridge ID (mm) | Ubukhulu. Ingcindezi(psi/bar) | Inani ngeBhokisi ngalinye | |
Encane | Okukhulu | |||||||
I-SW-2101-004-SP | 4g | 4mg–0.4g | 15–40 | 113.8 | 12.4 | 400/27.5 | 24 | 120 |
I-SW-2101-012-SP | 12g | 12mg–1.2g | 30–60 | 134.8 | 21.4 | 400/27.5 | 24 | 108 |
I-SW-2101-025-SP | 25g | 25mg–2.5g | 30–60 | 184 | 21.4 | 400/27.5 | 18 | 72 |
I-SW-2101-040-SP | 40g | 40mg–4.0g | 40–70 | 184.4 | 26.7 | 400/27.5 | 12 | 48 |
I-SW-2101-080-SP | 80g | 80mg–8.0g | 50–100 | 257.4 | 31.2 | 350/24.0 | 10 | 20 |
I-SW-2101-120-SP | 120g | 120mg–12g | 60–150 | 261.5 | 38.6 | 300/20.7 | 8 | 16 |
I-SW-2101-220-SP | 220g | 220mg–22g | 80–220 | 223.5 | 61.4 | 300/20.7 | 4 | 8 |
I-SW-2101-330-SP | 330g | 330mg–33g | 80–220 | 280.2 | 61.4 | 250/17.2 | 3 | 6 |
I-SW-2101-800-SP | 800g | 800mg-80g | 50-100 | 382.9 | 78.2 | 100/6.9 | 3 | - |
I-SW-2101-1600-SP | 1600g | 1.6g-160g | 50-100 | 432.4 | 103.8 | 100/6.9 | 2 | - |
I-SW-2101-3000-SP | 3kg | 3g-300g | 50-100 | 509.5 | 127.5 | 100/6.9 | 1 | - |
I-SW-2101-5000-SP | 5kg | 5g-500g | 50-100 | 770 | 127.5 | 100/6.9 | 1 | - |
I-SW-2101-010K-SP | 10kg | 10-1 kg | 50-100 | 850 | 172.5 | 100/6.9 | 1 | - |
※ Ihambisana nawo wonke amasistimu we-flash chromatography emakethe.
I-silica eyindilinga esebenza kahle kakhulu, 20−45 µm, 70 Å(indawo engaphezulu 500 m2/g, pH 6.0–8.0, umthamo wokulayisha 0.1–15%)
Inombolo Yento | Usayizi Wekholomu | Usayizi Wesampula(g) | Izinga lokugeleza(mL/min) | Ubude beCartridge (cm) | I-Cartridge ID (mm) | Ubukhulu. Ingcindezi(psi/bar) | Inani ngeBhokisi ngalinye | |
Encane | Okukhulu | |||||||
I-SW-2102-004-SP | 4g | 4mg–0.6g | 15–30 | 113.8 | 12.4 | 400/27.5 | 24 | 120 |
I-SW-2102-012-SP | 12g | 12mg–1.8g | 25-50 | 134.8 | 21.4 | 400/27.5 | 24 | 108 |
I-SW-2102-025-SP | 25g | 25mg–3.8g | 25-50 | 184 | 21.4 | 400/27.5 | 18 | 72 |
I-SW-2102-040-SP | 40g | 40mg–6.0g | 30–60 | 184.4 | 26.7 | 400/27.5 | 12 | 48 |
I-SW-2102-080-SP | 80g | 80mg–12g | 40–80 | 257.4 | 31.2 | 350/24.0 | 10 | 20 |
I-SW-2102-120-SP | 120g | 120mg–18g | 45–90 | 261.5 | 38.6 | 300/20.7 | 8 | 16 |
I-SW-2102-220-SP | 220g | 220mg–33g | 60–120 | 223.5 | 61.4 | 300/20.7 | 4 | 8 |
I-SW-2102-330-SP | 330g | 330mg–50g | 60–120 | 280.2 | 61.4 | 250/17.2 | 3 | 6 |
I-SW-2102-800-SP | 800g | 800mg-120g | 50-100 | 382.9 | 78.2 | 100/6.9 | 3 | - |
I-SW-2102-1600-SP | 1600g | 1.6g-240g | 50-100 | 432.4 | 103.8 | 100/6.9 | 2 | - |
I-SW-2102-3000-SP | 3kg | 3g-450g | 50-100 | 509.5 | 127.5 | 100/6.9 | 1 | - |
I-SW-2102-5000-SP | 5kg | 5g-750g | 50-100 | 770 | 127.5 | 100/6.9 | 1 | - |
I-SW-2102-010K-SP | 10kg | 10-1.5 kg | 50-100 | 850 | 172.5 | 100/6.9 | 1 | - |
※ Ihambisana nawo wonke amasistimu we-flash chromatography emakethe.
Umthamo omkhulu we-silica eyindilinga, 50 μm, 54 Å(indawo engaphezulu 700 m2/g, pH 6.0‒8.0, umthamo wokulayisha 0.1‒30%)
Inombolo Yento | Usayizi Wekholomu | Usayizi Wesampula(g) | Izinga lokugeleza(mL/min) | Ubude beCartridge (cm) | I-Cartridge ID (mm) | Ubukhulu. Ingcindezi(psi/bar) | Inani ngeBhokisi ngalinye | |
Encane | Okukhulu | |||||||
I-SW-2101-004-SP(H) | 4g | 4mg–1.2g | 15–30 | 113.8 | 12.4 | 400/27.5 | 24 | 120 |
I-SW-2101-012-SP(H) | 12g | 12mg–3.6g | 25-50 | 134.8 | 21.4 | 400/27.5 | 24 | 108 |
I-SW-2101-025-SP(H) | 25g | 25mg–7.5g | 25-50 | 184 | 21.4 | 400/27.5 | 18 | 72 |
I-SW-2101-040-SP(H) | 40g | 40mg–12g | 30-60 | 184.4 | 26.7 | 400/27.5 | 12 | 48 |
I-SW-2101-080-SP(H) | 80g | 80mg–24g | 40-80 | 257.4 | 31.2 | 350/24.0 | 10 | 20 |
I-SW-2101-120-SP(H) | 120g | 120mg–36g | 45-90 | 261.5 | 38.6 | 300/20.7 | 8 | 16 |
I-SW-2101-220-SP(H) | 220g | 220mg–66g | 60-120 | 223.5 | 61.4 | 300/20.7 | 4 | 8 |
I-SW-2101-330-SP(H) | 330g | 330mg–99g | 60-120 | 280.2 | 61.4 | 250/17.2 | 3 | 6 |
I-SW-2101-800-SP(H) | 800g | 800mg-240g | 50-100 | 382.9 | 78.2 | 100/6.9 | 3 | - |
I-SW-2101-1600-SP(H) | 1600g | 1.6g-480g | 50-100 | 432.4 | 103.8 | 100/6.9 | 2 | - |
I-SW-2101-3000-SP(H) | 3kg | 3g-900g | 50-100 | 509.5 | 127.5 | 100/6.9 | 1 | - |
I-SW-2101-5000-SP(H) | 5kg | 5g-1.5kg | 50-100 | 770 | 127.5 | 100/6.9 | 1 | - |
I-SW-2101-010K-SP(H) | 10kg | 10-3 kg | 50-100 | 850 | 172.5 | 100/6.9 | 1 | - |
※ Ihambisana nawo wonke amasistimu we-flash chromatography emakethe.
I-silica eyisiyingi yomthamo omkhulu, 25 µm, 50 Å(indawo engaphezulu 700 m2/g, pH 5.0–8.0, umthamo wokulayisha 0.1–30%)
Inombolo Yento | Usayizi Wekholomu | Usayizi Wesampula(g) | Izinga lokugeleza(mL/min) | Ubude beCartridge (cm) | I-Cartridge ID (mm) | Ubukhulu. Ingcindezi(psi/bar) | Inani ngeBhokisi ngalinye | |
Encane | Okukhulu | |||||||
I-SW-2102-004-SP(H) | 4g | 4mg–1.2g | 15–30 | 113.8 | 12.4 | 400/27.5 | 24 | 120 |
I-SW-2102-012-SP(H) | 12g | 12mg–3.6g | 25-50 | 134.8 | 21.4 | 400/27.5 | 24 | 108 |
I-SW-2102-025-SP(H) | 25g | 25mg–7.5g | 25-50 | 184 | 21.4 | 400/27.5 | 18 | 72 |
I-SW-2102-040-SP(H) | 40g | 40mg–12g | 30-60 | 184.4 | 26.7 | 400/27.5 | 12 | 48 |
I-SW-2102-080-SP(H) | 80g | 80mg–24g | 40-80 | 257.4 | 31.2 | 350/24.0 | 10 | 20 |
I-SW-2102-120-SP(H) | 120g | 120mg–36g | 45-90 | 261.5 | 38.6 | 300/20.7 | 8 | 16 |
I-SW-2102-220-SP(H) | 220g | 220mg–66g | 60-120 | 223.5 | 61.4 | 300/20.7 | 4 | 8 |
I-SW-2102-330-SP(H) | 330g | 330mg–99g | 60-120 | 280.2 | 61.4 | 250/17.2 | 3 | 6 |
I-SW-2102-800-SP(H) | 800g | 800mg-240g | 50-100 | 382.9 | 78.2 | 100/6.9 | 3 | - |
I-SW-2102-1600-SP(H) | 1600g | 1.6g-480g | 50-100 | 432.4 | 103.8 | 100/6.9 | 2 | - |
I-SW-2102-3000-SP(H) | 3kg | 3g-900g | 50-100 | 509.5 | 127.5 | 100/6.9 | 1 | - |
I-SW-2102-5000-SP(H) | 5kg | 5g-1.5kg | 50-100 | 770 | 127.5 | 100/6.9 | 1 | - |
I-SW-2102-010K-SP(H) | 10kg | 10-3 kg | 50-100 | 850 | 172.5 | 100/6.9 | 1 | - |
※ Ihambisana nawo wonke amasistimu we-flash chromatography emakethe.
I-silica eyisiyingi yomthamo omkhulu, 15 µm, 50 Å(indawo engaphezulu 700 m2/g, pH 5.0–8.0, umthamo wokulayisha 0.1–30%)
Inombolo Yento | Usayizi Wekholomu | Usayizi Wesampula(g) | Izinga lokugeleza(mL/min) | Ubude beCartridge (cm) | I-Cartridge ID (mm) | Ubukhulu. Ingcindezi(psi/bar) | Inani ngeBhokisi ngalinye | |
Encane | Okukhulu | |||||||
I-SW-2103-004-SP(H) | 4 g | 4 mg–1.2 g | 10–15 | 113.8 | 12.4 | 400/27.5 | 24 | 120 |
I-SW-2103-012-SP(H) | 12 g | 12 mg–3.6 g | 15–20 | 134.8 | 21.4 | 400/27.5 | 24 | 108 |
I-SW-2103-025-SP(H) | 25 g | 25 mg–7.5 g | 15–20 | 184 | 21.4 | 400/27.5 | 18 | 72 |
I-SW-2103-040-SP(H) | 40 g | 40 mg–12 g | 20–30 | 184.4 | 26.7 | 400/27.5 | 12 | 48 |
I-SW-2103-080-SP(H) | 80 g | 80 mg–24 g | 30–40 | 257.4 | 31.2 | 350/24.0 | 10 | 20 |
I-SW-2103-120-SP(H) | 120 g | 120 mg–36 g | 35–45 | 261.5 | 38.6 | 300/20.7 | 8 | 16 |
I-SW-2103-220-SP(H) | 220 g | 220 mg–66 g | 50–65 | 223.5 | 61.4 | 300/20.7 | 4 | 8 |
I-SW-2103-330-SP(H) | 330 g | 330 mg–99 g | 50–65 | 280.2 | 61.4 | 250/17.2 | 3 | 6 |
※ Iyahambisana nazo zonke izinhlelo ze-flash chromatography emakethe.
I-Double Laying Capacity of SepaFlash™ Cartridges epakishwe ngaphambili ngejeli ye-silica yomthamo omkhulu (700 m2/g ngo-50 Å usayizi wezimbotshana) iletha ukusebenza okuphezulu kakhulu kokuhlanza. I-silica eyisiyingi enamandla angu-25 µm noma engu-15 µm inendawo ephakeme engu-40%, iphinda kabili umthamo wokulayisha we-silica yendawo ephansi. U-Santai uhlole ukusebenza kwamakholomu e-SepaFlash™ ngokuqhathaniswa namabhrendi amabili aziwayo. Imiphumela ibonisa ukuthi i-SepaFlash™ idlula izimbangi.
- I-AN006-Ukuhlanzwa Kwe-Molecular Peptide Encane nge-SepaFlash™ HP Bio Series Flash Cartridge
- I-AN009-Ukuhlanzwa Kwe-Porphyrins ngomshini we-SepaBean™
- AN012-Ukusetshenziswa kwe-SepaFlash™ Cartridges ekuhlanzweni kwe-Diazo Compounds
- AN021_Ukusetshenziswa Kwesitaki Sekholomu Ekuhlanzweni Kwezinto Ze-Organic Optoelectronic
- AN022_Umthamo Wokulayisha Isampula Ephakeme, Ukusebenza Okungcono - Ukusetshenziswa Kwe-SepaFlash™Ruby High Resolution Cartridges
- AN023_SepaFlash™Ruby Series High Resolution Normal Isigaba Esijwayelekile Sekholomu Ye-Silicone Ukusebenzisa Kabusha Nomhlahlandlela Wesitoreji
- I-AN-SS-007-Reusable Santai SepaFlash™ Ruby Series Amakholomu Asebenzisa Ukwehlukana Kuze Kufike izikhathi eziyi-100
- Ikholomu ye-SepaFlash Ikhathalogi EN