isibhengezo_sekhasi

I-SepaFlash™ E Series

I-SepaFlash™ E Series

Incazelo emfushane:

Amakholomu e-flash ochungechunge akhiqizwa ngamakhatriji afanayo njengochungechunge olujwayelekile kodwa apakishwe ngejeli ye-silica eyongayo, yekhwalithi ephezulu (40-63 µm, 60 Å) noma 50-75 µm alumina.

※ Izici ezifanayo ze-cartridge ezinochungechunge olujwayelekile.

※ Iwusizo kumasampula abucayi.

※ Ijwayele ukucekelwa phansi ijeli ye-silica.

※ Imali yokonga yokuhlanza njalo.


Imininingwane Yomkhiqizo

Isicelo

Ividiyo

ikhathalogi

Amapharamitha womkhiqizo

I-silica engavamile yekhwalithi ephezulu, 40–63 µm, 60 Å(indawo engaphezulu 500 m2/g, pH 6.5–7.5, umthamo wokulayisha 0.1–10%)

Inombolo Yento Usayizi Wekholomu Usayizi Wesampula(g) Izinga lokugeleza(mL/min) Ubude beCartridge (cm) I-Cartridge ID (mm) Ubukhulu.Ingcindezi(psi/bar) Inani ngeBhokisi ngalinye
Encane Okukhulu
S-8101-0004 4 g 4 mg–0.4 g 15–40 105.8 12.4 300/20.7 36 120
S-8101-0012 12 g 12 mg–1.2 g 30–60 124.5 21.2 300/20.7 24 108
S-8101-0025 25 g 25 mg–2.5 g 30–60 172.7 21.3 300/20.7 20 80
S-8101-0040 40 g 40 mg–4.0 g 40–70 176 26.7 300/20.7 15 60
S-8101-0080 80 g 80 mg–8.0 g 50–100 248.5 30.9 200/13.8 10 20
I-S-8101-0120 120 g 120 mg–12 g 60–150 261.5 37.2 200/13.8 8 16
S-8101-0220 220 g 220 mg–22 g 80–220 215.9 59.4 150/10.3 4 8
S-8101-0330 330 g 330 mg–33 g 80–220 280.3 59.8 150/10.3 3 6
S-8101-0800 800 g 800 mg-80 g 100–300 382.9 78.2 100/6.9 3 /
I-S-8101-1600 1600 g 1.6 g–160 g 200–500 432.4 103.8 100/6.9 2 /
I-S-8101-3000 3000 g 3.0 g–300 g 200–500 509.5 127.5 100/6.9 1 /

※ Iyahambisana nazo zonke izinhlelo ze-flash chromatography emakethe.

I-alumina engajwayelekile yekhwalithi ephezulu, 50–75 µm, 55 Å
(pH: acidic 3.8–4.8, neutral 6.5–7.5, basic 9.0–10.0; indawo engaphezulu 155 m2/g, umthamo wokulayisha 0.1–4%)
Nge-alumina ene-asidi, buyisela u-“N” ngokuthi “A” enombolweni yento, kanye ne-alumina eyisisekelo ngo-“B”.

Inombolo Yento Usayizi Wekholomu Usayizi Wesampula(g) Izinga lokugeleza(mL/min) Ubude beCartridge (cm) I-Cartridge ID (mm) Ubukhulu.Ingcindezi(psi/bar) Inani ngeBhokisi ngalinye
Encane Okukhulu
I-S-8601-0004-N 8 g 8 mg–0.32 g 10–30 105.8 12.4 300/20.7 36 120
I-S-8601-0012-N 24 g 24 mg–1.0 g 15–45 124.5 21.2 300/20.7 24 108
I-S-8601-0025-N 50 g 50 mg–2.0 g 15–45 172.7 21.3 300/20.7 20 80
I-S-8601-0040-N 80 g 80 mg–3.2 g 20–50 176 26.7 300/20.7 15 60
I-S-8601-0080-N 160 g 160 mg–6.4 g 30–70 248.5 30.9 200/13.8 10 20
I-S-8601-0120-N 240 g 240 mg–9.6 g 40–80 261.5 37.2 200/13.8 8 16
I-S-8601-0220-N awu 440g 440 mg–17.6 g 50–120 215.9 59.4 150/10.3 4 8
I-S-8601-0330-N awu 660g 660 mg–26.4 g 50–120 280.3 59.8 150/10.3 3 6
I-S-8601-0800-N 1600 g 1.6 g–64 g 100–200 382.9 78.2 100/6.9 3 /
I-S-8601-1600-N 3200 g 3.2 g–128 g 150-300 432.4 103.8 100/6.9 2 /
I-S-8601-3000-N 6000 g 6.0 g–240 g 150-300 509.5 127.5 100/6.9 1 /

※ Iyahambisana nazo zonke izinhlelo ze-flash chromatography emakethe.