Ikhasi_Banjaneri

Umshini weSepabean ™ Umshini 2

Umshini weSepabean ™ Umshini 2

Incazelo emfushane:

● Imodeli yengcindezi ephakathi engahambelana kahle ne-Sepaflash ™ spin-welded kholomu yokusebenza kahle kokuhlukaniswa okuphezulu.

● Gradient kanambambili nanoma yikuphi ukuhlanganiswa kwama-solvents amabili, i-solvent yesi-3 njenge-modifier, ekwazi ukuhambisa izimo eziyinkimbinkimbi zokuhlukanisa.

● Okokuzithandela i-ELSD ukumboza izinhlobo eziningi zamasampula.


Imininingwane Yomkhiqizo

Inkomba

Isicelo

Ividiyo

Amapharamitha Womkhiqizo

Isifanekiso Umshini weSepabean ™ Umshini 2
Into No. SPB05000300-1 SPB05000300-2
Umtshingo U-UV oguquguqukayo we-DAD (200 - 400 NM) U-DAD oguquguqukayo UV (200 - 400 NM) + VISS (400 - 800 NM)
Ububanzi bokuhamba 1 - 300 ml / min
Ingcindezi enkulu I-500 PSI (33.5 Bar)
Uhlelo lokupompa Amaphampu anembe kakhulu ama-piston
Iviyo Ama-sol amane kanambambili nge-solvent yesi-3 njenge-modifier
Umthamo wokulayisha isampula 10 mg - 33 g
Amalunga wekholomu 4 g - 330 g, kuze kufike ku-3 kg nge-adaptha
Izinhlobo ze-Gradient Esescy, Linear, Isinyathelo
I-Flowcell Optical Path ubude 0.3 mm (okuzenzakalelayo); 2.4 mm (ngokuzithandela)
Isibonisi Sokubukeka single / dual / wonke-wavelength
Indlela yokulayisha isampula umthwalo wesandla
Ingxenyenamba konke, imfucuza, umkhawulo, ithambeka, isikhathi
Umqoqi wengxenye Okujwayelekile: Amashubhu (13 mm, 15 mm, 16mm, 18 mm, 25 mm);
Ongakukhetha: Ibhodlela Lesikwele French (250 ml, 500 ml) noma ibhodlela leqoqo elikhulu;
Isitsha esenziwe ngokwezifiso
Idivaysi yokulawula ukusebenza okungenantambo ngamadivayisi eselula *
Isitifiketi CE
* I-iPad

Izici zesistimu ye-Flash Chromatography System Sepabean ™ Machine 2

Ukusebenza okungenantambo ngamadivayisi eselula
Indlela yokulawula engenantambo engenantambo ilungele ikakhulukazi izivivinyo zokwehlukanisa ezidinga ukuvikeleka ekukhanyeni noma ezibekwe e-i-i-i-i-i-i-i-iholo.

Ukubuyiselwa kwamandla Ukubuyiselwa kwamandla
Umsebenzi wokululama we-Power-off eyakhelwe ngaphakathi kwisoftware inciphisa ukulahleka okubangelwa ukwehluleka kwamandla ngengozi.

Isincomo Sendlela Yokuhlukanisa
Isoftware ine-database yendlela eyakhelwe ngaphakathi yokuhlukanisa encoma ngokuzenzakalelayo indlela efanelekile yokuhlukanisa ngokususelwa kulwazi olusemqoka olufakwe ngumsebenzisi, ngaleyo ndlela kuthuthukise ukusebenza kahle komsebenzi.

Umqoqi wengxenye
Ama-racks we-TUBE nge-LCD Display Vumela abasebenzisi ukulandelela kalula amashubhu aqukethe izingxenyana eziqoqiwe.

Ukwabelana ngedatha yendawo yendawo
Izinsimbi eziningi zingakha inethiwekhi yendawo yendawo ukwenza lula ukwabiwa kwedatha yangaphakathi nokusebenziseka kwezinsizakusebenza kwelebhu.

21-CFR Ingxenye 11 Ukuhambisana
Isoftware yokulawula ihambisana nezidingo ze-FDA zokuphepha kohlelo (21-CFR ingxenye 11), okwenza ithuluzi lilungele izinkampani ze-R & D kanye nama-laboratoriates.

Uhlelo lokuhlanza oluhle lwenza ukuhlanzwa kube lula
I-Smart Flash Chromagraphy System Sepabean ™ Machine 2 eyethulwe ubuchwepheshe beSantai inesici esakhelwe ngaphakathi sokunconywa kwendlela yokuhlukanisa. Ngisho nabaqalayo noma abasebenza nge-chromatography abasebenza nge-chromatography bangaqedela kalula umsebenzi wokuhlanza.

Ukuhlanzwa okuhle nge- "Touch & Go" Easplicity
Umshini we-Sepabean ™ usebenza ngedivayisi yeselula, nge-UI ephathekayo, ilula ngokwanele kwabaqalayo nabangewona ochwepheshe ukuqedela ukuhlukaniswa okujwayelekile, kepha futhi kungokwesisekelo ngokwanele ukuthi uchwepheshe noma i-guru ukuqeda noma ukwenze kahle ukwahlukana okuyinkimbinkimbi.

Database Yakhelwe ngaphakathi - Ulwazi Lugcinwe
Abaphenyi emhlabeni jikelele bachitha izinsizakusebenza eziningi ukuthuthukisa izindlela zokuhlukanisa nokuhlanza izingxube, noma ukukhishwa okuvela emikhiqizweni yemvelo, lezi zindlela ezibalulekile zivame ukugcinwa endaweni eyodwa, zihlukaniswe, zihlanjwe, futhi zibe "isiqhingi solwazi" ngaleso sikhathi. Ngokungafani nethuluzi lendabuko le-Flash, umshini we-Sepabean ™ 2 usebenzisa i-database futhi usabalalisa ubuchwepheshe bekhompyutha ukuze bagcine futhi babelane ngalezi zindlela enhlanganweni evikelekile yenhlangano:
● Umshini we-Sepabean ™ oboshwe amalungelo obunikazi we-database ohlanganyele ukuze ugcine izindlela zokwehlukanisa, abacwaningi bangabuza indlela ekhona noma bavuselele indlela entsha yokuhlukanisa umane nje besebenzisa igama elihlanganisiwe, isakhiwo noma ikhodi yephrojekthi.
● Umshini we-Sepabean ™ ulungile, izinsimbi eziningi ngaphakathi kwenhlangano zingakha isiteshi sangasese, ukuze izindlela zokuhlukanisa zingabiwa kulo lonke inhlangano, abacwaningi abagunyaziwe bangangena futhi basebenzise lezi zindlela ngqo ngaphandle kokuthuthukisa izindlela.
● Umshini we-Sepabean ™ 2 ungathola futhi uxhumeke kuthuluzi lontanga ngokuzenzakalela, uma izinsimbi eziningi zixhunyiwe, idatha ivumelaniswa ngokuzenzakalela, abacwaningi bangafinyelela izindlela zabo kunoma iyiphi indawo exhunyiwe kunoma iyiphi indawo exhunyiwe kusuka kunoma iyiphi indawo exhunyiwe kusuka kunoma iyiphi indawo exhunyiwe kusuka kunoma iyiphi indawo exhunyiwe kusuka kunoma iyiphi indawo exhunyiwe kusuka kunoma iyiphi indawo exhunyiwe kunoma iyiphi indawo.


  • Okwedlule:
  • Olandelayo:

    • Ikhathalogi yomshini weSepabean
      Ikhathalogi yomshini weSepabean
    • I-AN014_Revent of the resolution nge-Colom Stacking kanye nesicelo sayo
      I-AN014_Revent of the resolution nge-Colom Stacking kanye nesicelo sayo
    • Isigaba sesigaba se-AN015_HyDrophobic, i-AQ ibuyiselwe amakholomu e-Chromatography Chromatography
      Isigaba sesigaba se-AN015_HyDrophobic, i-AQ ibuyiselwe amakholomu e-Chromatography Chromatography
    • I-AN016_Ukusetshenziswa kwe-Sepaflash ™ Conf Conf Conf Exchange Exchange Colombs ekuhlanzweni kwamakhompiyutha e-Alkaline
      I-AN016_Ukusetshenziswa kwe-Sepaflash ™ Conf Conf Conf Exchange Exchange Colombs ekuhlanzweni kwamakhompiyutha e-Alkaline
    • I-AN018_Ukusetshenziswa kwamakholomu we-C18AQ ekuhlanzeni kwama-polar peptides aqinile
      I-AN018_Ukusetshenziswa kwamakholomu we-C18AQ ekuhlanzeni kwama-polar peptides aqinile
    • I-AN019_Ukuhlanzwa kokungcola kwe-polar kakhulu kuma-antibiotic ngamakholomu e-C18AQ
      I-AN019_Ukuhlanzwa kokungcola kwe-polar kakhulu kuma-antibiotic ngamakholomu e-C18AQ
    • I-A021_Ukusebenza kwekholomu ifaka ekuhlanzeni kwezinto eziphilayo ze-Orpolectronic
      I-A021_Ukusebenza kwekholomu ifaka ekuhlanzeni kwezinto eziphilayo ze-Orpolectronic
    • Umthamo wesampula wesampula we-AN022_Her
      Umthamo wesampula wesampula we-AN022_Her
    • I-AN032_Ukuhlanzwa kwama-diateseomers yi-Sepaflash ™ C18 eguqulwe kabusha i-CARGHTRARDICE
      I-AN032_Ukuhlanzwa kwama-diateseomers yi-Sepaflash ™ C18 eguqulwe kabusha i-CARGHTRARDICE
    • Ukuhlukaniswa kwe-AN-002 kwe-CBDA ne-THCA kusuka ku-cannabis nokuhambisana kwayo kwe-cannabinoid ekhiqizwayo ye-biotechnological
      Ukuhlukaniswa kwe-AN-002 kwe-CBDA ne-THCA kusuka ku-cannabis nokuhambisana kwayo kwe-cannabinoid ekhiqizwayo ye-biotechnological
    • I-An-003 Fangiswation Harudization of Stage-Scale Steric Steric Carbohydrate nge-Sepabean ™ umshini
      I-An-003 Fangiswation Harudization of Stage-Scale Steric Steric Carbohydrate nge-Sepabean ™ umshini
    • Inqubo ye-AN-SS-004 Rapid isolative ye-Δ9-tetrahydocanilic acid a (Thca) kusuka ku-Cannabis Sativa L. Usebenzisa ama-Shepabean ™ Flash Chromatography Systems
      Inqubo ye-AN-SS-004 Rapid isolative ye-Δ9-tetrahydocanilic acid a (Thca) kusuka ku-Cannabis Sativa L. Usebenzisa ama-Shepabean ™ Flash Chromatography Systems
    • Indlela ye-An-005 yokukhishwa kwendlela yokukhishwa kwe-cannabidiolic acid kusuka ku-cannabis sativa L. usebenzisa ama-Shepabean ™ flash chromatography Systems
      Indlela ye-An-005 yokukhishwa kwendlela yokukhishwa kwe-cannabidiolic acid kusuka ku-cannabis sativa L. usebenzisa ama-Shepabean ™ flash chromatography Systems
    • Umhlahlandlela weSepabean Machine 2
    • Ukuhlelwa kwedivaysi ye-Sepabean - Ukulinganisa kwe-Tube Rack
    • Ukulungiswa kweSepabean - i-nozzle ihlanzekile
    • Ukulungiswa kweSepabean - ukuhlanza umoya
    • Ukulungiswa kweSepabean - Ukulinganisa kwePump
    Bhala umyalezo wakho lapha bese usithumela kithi