iphepha_ibhena

SepaFlash™ iLOK™ Series

SepaFlash™ iLOK™ Series

Inkcazelo emfutshane:

I-SepaFlash iLOK™ iikhatriji zeflash zinika abasebenzisi ithuba lokudityaniswa ngezandla, ezivumela indlela yokulayisha isampulu eguquguqukayo: umthwalo oqinileyo kunye nenaliti yolwelo ethe ngqo.

※ Iintlobo ezi-3 ze-iLok flash cartridge onokukhetha kuzo, kubandakanya ikhatriji engenanto, ikhatriji epakishwe kwangaphambili kunye ne-75% yekhatriji epakishwe kwangaphambili.


Iinkcukacha zeMveliso

Isicelo

Ividiyo

ikhathalogu

Intshayelelo yeMveliso

I-SepaFlash™ iLOK™ iikhatriji zeflash zinika abasebenzisi ithuba lokudityaniswa ngezandla, ezivumela indlela yokulayisha isampulu eguquguqukayo: umthwalo oqinileyo kunye nenaliti yolwelo ethe ngqo. Olu ngcelele lubonelelwa ngeefomathi ezintathu: iLOK™ flash cartridge epakishwe kwangaphambili ngejeli yesilica yeUltraPure, iLOK™ SL ikhatriji epakishwe kwangaphambili nge 85% yomthamo wekholomu yesilica gel kunye neLOK™ engenanto engenanto yomthwalo oqinileyo ikhatriji iza ne-screw cap, iifrits. , iyunithi yokuhlawula, i-O-ring kunye neengcebiso zokugqibela.

※ Uyilo lwekholamu entsha lulungele ukudibanisa ngesandla kunye nokupakishwa kwekholamu.
※ Ifumaneka kuluhlu olubanzi lweesayizi zekhatriji kuyo nayiphi na imeko.
※ Ukuqinisa umzimba we-cartridge kunye noxinzelelo oluphezulu lokusebenza ukuya kwi-200 psi.

Ukuodola Ulwazi

I-iLOK™ Flash Cartridges (epakishwe kwangaphambili, i-silica ye-UltraPure irregular, 40−63 µm, 60 Å)
(ummandla ongaphezulu kwama-500 m2/g, pH 6.5-7.5, umthamo wokulayisha 0.1-10%)

Inombolo yento Ubungakanani beKholam Ubungakanani beSampuli Inqanaba lokuHamba (mL/min) Ubude beCartridge (mm) ICartridge ID (mm) Max. Uxinzelelo (psi/bar) Ubungakanani kwiBhokisi nganye
Incinci Enkulu
SD-5101-004 4 g 4 mg–0.4 g 15–40 115.1 12.8 200/13.8 24 120
SD-5101-012 12 g 12 mg–1.2 g 30–60 137.8 21.4 200/13.8 24 108
SD-5101-025 25 g 25 mg–2.5 g 30–60 188.2 21.6 200/13.8 20 80
SD-5101-040 40 g 40 mg–4.0 g 40–70 188.7 26.8 200/13.8 12 48
SD-5101-060 60 g 60 mg–6.0 g 60–150 173.3 36.6 200/13.8 12 24
SD-5101-080 80 g 80 mg–8.0 g 50–100 263.5 31.2 200/13.8 10 20
SD-5101-100 100 g 100 mg–10 g 80–220 146.6 60.4 150/10.3 6 12
SD-5101-120 120 g 120 mg–12 g 60–150 277.7 36.6 200/13.8 8 16
SD-5101-220 220 g 220 mg–22 g 80–220 218.5 60.6 150/10.3 4 8
SD-5101-330 330 g 330 mg–33 g 80–220 271.6 60.6 150/10.3 2 5

※ Iyahambelana nazo zonke iinkqubo zekhromatografi kwimarike.

I-iLOK™ Iikhatriji zoMlayisho oSolidi ongenanto
(i-iLOK™ ingenanto yomthwalo oqinileyo wekhatriji ene-screw cap, iifrits, iyunithi yokukhupha, i-O-ring kunye neengcebiso zokuphela.)

Inombolo yento Inkcazo Umthamo (mL) Ubude beCartridge (mm) ICartridge ID (mm) Max. Uxinzelelo (psi/bar) Ubungakanani kwiBhokisi nganye
Incinci Enkulu
SD-0000-004 Ikhatriji yomthwalo oqinileyo ongenanto, 4 g 8 115.1 12.8 200/13.8 24 120
SD-0000-012 Ikhatriji yomthwalo oqinileyo ongenanto, 12 g 27 137.8 21.4 200/13.8 24 108
SD-0000-025 Ikhatriji yomthwalo oqinileyo ongenanto, 25 g 46 188.2 21.6 200/13.8 20 80
SD-0000-040 Ikhatriji yomthwalo oqinileyo ongenanto, 40 g 70 188.7 26.8 200/13.8 12 48
SD-0000-060 Ikhatriji yomthwalo oqinileyo ongenanto, 60 g 104 173.3 36.6 200/13.8 12 24
SD-0000-080 Ikhatriji yomthwalo oqinileyo ongenanto, 80 g 147 263.5 31.2 200/13.8 10 20
SD-0000-100 Ikhatriji yomthwalo oqinileyo ongenanto, 100 g 176 146.6 60.4 150/10.3 6 12
SD-0000-120 Ikhatriji yomthwalo oqinileyo ongenanto, 120 g 215 277.7 36.6 200/13.8 8 16
SD-0000-220 Ikhatriji yomthwalo oqinileyo ongenanto, 220 g 376 218.5 60.6 150/10.3 4 8
SD-0000-330 Ikhatriji yomthwalo oqinileyo ongenanto, 330 g 539 271.6 60.6 150/10.3 2 5
SD-0000-0800B Ikhatriji yomthwalo oqinileyo ongenanto, 800 g 1395 140 127 100/6.9 1 /
SD-0000-1600B Ikhatriji yomthwalo oqinileyo ongenanto, 1600 g 2760 250 127 100/6.9 1 /
SD-0000-3000B Ikhatriji yomthwalo oqinileyo ongenanto, 3000 g 5165 440 127 100/6.9 1 /
SD-0000-5000B Ikhatriji yomthwalo oqinileyo ongenanto, 5000 g 8610 692 127 100/6.9 1 /
SD-0000-7000B Ikhatriji yomthwalo oqinileyo ongenanto, 7000 g 12510 1000 127 100/6.9 1 /

※ Iyahambelana nazo zonke iinkqubo zekhromatografi kwimarike.

Ulungelelwaniso lokulayisha okuqinileyo

Ukulayishwa kwesampulu eqinile kunobuchule bokulayisha iisampuli eziza kuhlanjululwa kwikholamu, ngakumbi kwimeko yeesampulu zokunyibilika okuphantsi. Ngesi sihlandlo, i-ILOK™ flash cartridge lukhetho olufanelekileyo.

Isampulu inyibilika kwisinyibilikisi esifanelekileyo kwaye ifunxelwe kumhlaba wediatomaceous. Emva kokususwa kwe-solvent eseleyo, i-adsorbent ibekwe phezu kwe-cartridge egcwele inxalenye okanye kwi-cartridge engenanto.

ilok

  • Ngaphambili:
  • Okulandelayo:

    • I-AN005-SepaFlash™ iiMveliso ezinkulu zokuCoca kumakhulu eegram zeSampuli
      I-AN005-SepaFlash™ iiMveliso ezinkulu zokuCoca kumakhulu eegram zeSampuli
    • SepaFlash ikholamu yeKhathalogu EN
      SepaFlash ikholamu yeKhathalogu EN
    • iLOK Ⅲ Ubungakanani obukhulu beCartridge yoMlayisho oZinzileyo ongenanto
      iLOK Ⅲ Ubungakanani obukhulu beCartridge yoMlayisho oZinzileyo ongenanto
    • Incwadana yeCartridge ye-ILOK-SL
      Incwadana yeCartridge ye-ILOK-SL
    • Indlela yokudibanisa ikholamu ye-iLok kunye ne-Biotage* SP1 kunye ne-SP4
      Indlela yokudibanisa ikholamu ye-iLok kunye ne-Biotage* SP1 kunye ne-SP4
    Bhala umyalezo wakho apha kwaye uwuthumele kuthi