SepaFlash™ iLOK™ Series
I-SepaFlash™ iLOK™ iikhatriji zeflash zinika abasebenzisi ithuba lokudityaniswa ngezandla, ezivumela indlela yokulayisha isampulu eguquguqukayo: umthwalo oqinileyo kunye nenaliti yolwelo ethe ngqo. Olu ngcelele lubonelelwa ngeefomathi ezintathu: iLOK™ flash cartridge epakishwe kwangaphambili ngejeli yesilica yeUltraPure, iLOK™ SL ikhatriji epakishwe kwangaphambili nge 85% yomthamo wekholomu yesilica gel kunye neLOK™ engenanto engenanto yomthwalo oqinileyo ikhatriji iza ne-screw cap, iifrits. , iyunithi yokuhlawula, i-O-ring kunye neengcebiso zokugqibela.
※ Uyilo lwekholamu entsha lulungele ukudibanisa ngesandla kunye nokupakishwa kwekholamu.
※ Ifumaneka kuluhlu olubanzi lweesayizi zekhatriji kuyo nayiphi na imeko.
※ Ukuqinisa umzimba we-cartridge kunye noxinzelelo oluphezulu lokusebenza ukuya kwi-200 psi.
I-iLOK™ Flash Cartridges (epakishwe kwangaphambili, i-silica ye-UltraPure irregular, 40−63 µm, 60 Å)
(ummandla ongaphezulu kwama-500 m2/g, pH 6.5-7.5, umthamo wokulayisha 0.1-10%)
Inombolo yento | Ubungakanani beKholam | Ubungakanani beSampuli | Inqanaba lokuHamba (mL/min) | Ubude beCartridge (mm) | ICartridge ID (mm) | Max. Uxinzelelo (psi/bar) | Ubungakanani kwiBhokisi nganye | ||
Incinci | Enkulu | ||||||||
SD-5101-004 | 4 g | 4 mg–0.4 g | 15–40 | 115.1 | 12.8 | 200/13.8 | 24 | 120 | |
SD-5101-012 | 12 g | 12 mg–1.2 g | 30–60 | 137.8 | 21.4 | 200/13.8 | 24 | 108 | |
SD-5101-025 | 25 g | 25 mg–2.5 g | 30–60 | 188.2 | 21.6 | 200/13.8 | 20 | 80 | |
SD-5101-040 | 40 g | 40 mg–4.0 g | 40–70 | 188.7 | 26.8 | 200/13.8 | 12 | 48 | |
SD-5101-060 | 60 g | 60 mg–6.0 g | 60–150 | 173.3 | 36.6 | 200/13.8 | 12 | 24 | |
SD-5101-080 | 80 g | 80 mg–8.0 g | 50–100 | 263.5 | 31.2 | 200/13.8 | 10 | 20 | |
SD-5101-100 | 100 g | 100 mg–10 g | 80–220 | 146.6 | 60.4 | 150/10.3 | 6 | 12 | |
SD-5101-120 | 120 g | 120 mg–12 g | 60–150 | 277.7 | 36.6 | 200/13.8 | 8 | 16 | |
SD-5101-220 | 220 g | 220 mg–22 g | 80–220 | 218.5 | 60.6 | 150/10.3 | 4 | 8 | |
SD-5101-330 | 330 g | 330 mg–33 g | 80–220 | 271.6 | 60.6 | 150/10.3 | 2 | 5 |
※ Iyahambelana nazo zonke iinkqubo zekhromatografi kwimarike.
I-iLOK™ Iikhatriji zoMlayisho oSolidi ongenanto
(i-iLOK™ ingenanto yomthwalo oqinileyo wekhatriji ene-screw cap, iifrits, iyunithi yokukhupha, i-O-ring kunye neengcebiso zokuphela.)
Inombolo yento | Inkcazo | Umthamo (mL) | Ubude beCartridge (mm) | ICartridge ID (mm) | Max. Uxinzelelo (psi/bar) | Ubungakanani kwiBhokisi nganye | |
Incinci | Enkulu | ||||||
SD-0000-004 | Ikhatriji yomthwalo oqinileyo ongenanto, 4 g | 8 | 115.1 | 12.8 | 200/13.8 | 24 | 120 |
SD-0000-012 | Ikhatriji yomthwalo oqinileyo ongenanto, 12 g | 27 | 137.8 | 21.4 | 200/13.8 | 24 | 108 |
SD-0000-025 | Ikhatriji yomthwalo oqinileyo ongenanto, 25 g | 46 | 188.2 | 21.6 | 200/13.8 | 20 | 80 |
SD-0000-040 | Ikhatriji yomthwalo oqinileyo ongenanto, 40 g | 70 | 188.7 | 26.8 | 200/13.8 | 12 | 48 |
SD-0000-060 | Ikhatriji yomthwalo oqinileyo ongenanto, 60 g | 104 | 173.3 | 36.6 | 200/13.8 | 12 | 24 |
SD-0000-080 | Ikhatriji yomthwalo oqinileyo ongenanto, 80 g | 147 | 263.5 | 31.2 | 200/13.8 | 10 | 20 |
SD-0000-100 | Ikhatriji yomthwalo oqinileyo ongenanto, 100 g | 176 | 146.6 | 60.4 | 150/10.3 | 6 | 12 |
SD-0000-120 | Ikhatriji yomthwalo oqinileyo ongenanto, 120 g | 215 | 277.7 | 36.6 | 200/13.8 | 8 | 16 |
SD-0000-220 | Ikhatriji yomthwalo oqinileyo ongenanto, 220 g | 376 | 218.5 | 60.6 | 150/10.3 | 4 | 8 |
SD-0000-330 | Ikhatriji yomthwalo oqinileyo ongenanto, 330 g | 539 | 271.6 | 60.6 | 150/10.3 | 2 | 5 |
SD-0000-0800B | Ikhatriji yomthwalo oqinileyo ongenanto, 800 g | 1395 | 140 | 127 | 100/6.9 | 1 | / |
SD-0000-1600B | Ikhatriji yomthwalo oqinileyo ongenanto, 1600 g | 2760 | 250 | 127 | 100/6.9 | 1 | / |
SD-0000-3000B | Ikhatriji yomthwalo oqinileyo ongenanto, 3000 g | 5165 | 440 | 127 | 100/6.9 | 1 | / |
SD-0000-5000B | Ikhatriji yomthwalo oqinileyo ongenanto, 5000 g | 8610 | 692 | 127 | 100/6.9 | 1 | / |
SD-0000-7000B | Ikhatriji yomthwalo oqinileyo ongenanto, 7000 g | 12510 | 1000 | 127 | 100/6.9 | 1 | / |
※ Iyahambelana nazo zonke iinkqubo zekhromatografi kwimarike.
Ukulayishwa kwesampulu eqinile kunobuchule bokulayisha iisampuli eziza kuhlanjululwa kwikholamu, ngakumbi kwimeko yeesampulu zokunyibilika okuphantsi. Ngesi sihlandlo, i-ILOK™ flash cartridge lukhetho olufanelekileyo.
Isampulu inyibilika kwisinyibilikisi esifanelekileyo kwaye ifunxelwe kumhlaba wediatomaceous. Emva kokususwa kwe-solvent eseleyo, i-adsorbent ibekwe phezu kwe-cartridge egcwele inxalenye okanye kwi-cartridge engenanto.
- I-AN005-SepaFlash™ iiMveliso ezinkulu zokuCoca kumakhulu eegram zeSampuli
- SepaFlash ikholamu yeKhathalogu EN
- iLOK Ⅲ Ubungakanani obukhulu beCartridge yoMlayisho oZinzileyo ongenanto
- Incwadana yeCartridge ye-ILOK-SL
- Indlela yokudibanisa ikholamu ye-iLok kunye ne-Biotage* SP1 kunye ne-SP4