iphepha_ibhena

SepaFlash™ E Series

SepaFlash™ E Series

Inkcazelo emfutshane:

Uthotho lwekholamu ezifunyazayo zenziwa ngeekhatriji ezifanayo njengothotho olusemgangathweni kodwa zipakishwe ngokoqoqosho, ijeli ye-silica ekumgangatho ophezulu (40-63 µm, 60 Å) okanye 50-75 µm alumina.

※ Iimpawu ezifanayo zekhatriji ezinothotho olusemgangathweni.

※ Iluncedo kwiisampulu ezibuthathaka.

※ Uthanda ukuthotywa kwijeli ye-silica.

※ Ukugcina imali yokucoca rhoqo.


Iinkcukacha zeMveliso

Isicelo

Ividiyo

ikhathalogu

Iiparamitha zeMveliso

Umgangatho ophezulu wesilika ongaqhelekanga, 40–63 µm, 60 Å(ummandla ongaphezulu kwama-500 m2/g, pH 6.5-7.5, umthamo wokulayisha 0.1-10%)

Inombolo yento Ubungakanani beKholam Ubungakanani beSampuli(g) Inqanaba lokuHamba(mL/min) Ubude beCartridge (cm) ICartridge ID (mm) Max.Uxinzelelo (psi/bar) Ubungakanani kwiBhokisi nganye
Incinci Enkulu
S-8101-0004 4 g 4 mg–0.4 g 15–40 105.8 12.4 300/20.7 36 120
S-8101-0012 12 g 12 mg–1.2 g 30–60 124.5 21.2 300/20.7 24 108
S-8101-0025 25 g 25 mg–2.5 g 30–60 172.7 21.3 300/20.7 20 80
S-8101-0040 40 g 40 mg–4.0 g 40–70 176 26.7 300/20.7 15 60
S-8101-0080 80 g 80 mg–8.0 g 50–100 248.5 30.9 200/13.8 10 20
S-8101-0120 120 g 120 mg–12 g 60–150 261.5 37.2 200/13.8 8 16
S-8101-0220 220 g 220 mg–22 g 80–220 215.9 59.4 150/10.3 4 8
S-8101-0330 330 g 330 mg–33 g 80–220 280.3 59.8 150/10.3 3 6
S-8101-0800 800 g 800 mg–80 g 100–300 382.9 78.2 100/6.9 3 /
S-8101-1600 1600 g 1.6 g–160 g 200–500 432.4 103.8 100/6.9 2 /
S-8101-3000 3000 g 3.0 g–300 g 200–500 509.5 127.5 100/6.9 1 /

※ Iyahambelana nazo zonke iinkqubo zekhromatografi kwimarike.

Umgangatho ophezulu we-alumina engaqhelekanga, 50–75 µm, 55 Å
(pH: i-acidic 3.8-4.8, i-6.5-7.5 engathathi hlangothi, i-9.0-10.0 esisiseko; indawo ephezulu 155 m2 / g, umthamo wokulayisha 0.1-4%)
Kwi-alumina eneasidi, buyisela u-“N” ngo-“A” kwinombolo yento, kunye ne-alumina esisiseko ngo-“B”.

Inombolo yento Ubungakanani beKholam Ubungakanani beSampuli(g) Inqanaba lokuHamba(mL/min) Ubude beCartridge (cm) ICartridge ID (mm) Max.Uxinzelelo (psi/bar) Ubungakanani kwiBhokisi nganye
Incinci Enkulu
S-8601-0004-N 8 g 8 mg–0.32 g 10–30 105.8 12.4 300/20.7 36 120
S-8601-0012-N 24 g 24 mg–1.0 g 15–45 124.5 21.2 300/20.7 24 108
S-8601-0025-N 50 g 50 mg–2.0 g 15–45 172.7 21.3 300/20.7 20 80
S-8601-0040-N 80 g 80 mg–3.2 g 20–50 176 26.7 300/20.7 15 60
S-8601-0080-N 160 g 160 mg–6.4 g 30–70 248.5 30.9 200/13.8 10 20
S-8601-0120-N 240 g 240 mg–9.6 g 40–80 261.5 37.2 200/13.8 8 16
S-8601-0220-N 440 g 440 mg–17.6 g 50–120 215.9 59.4 150/10.3 4 8
S-8601-0330-N 660 g 660 mg–26.4 g 50–120 280.3 59.8 150/10.3 3 6
S-8601-0800-N 1600 g 1.6 g–64 g 100–200 382.9 78.2 100/6.9 3 /
S-8601-1600-N 3200 g 3.2 g–128 g 150–300 432.4 103.8 100/6.9 2 /
S-8601-3000-N 6000 g 6.0 g–240 g 150–300 509.5 127.5 100/6.9 1 /

※ Iyahambelana nazo zonke iinkqubo zekhromatografi kwimarike.


  • Ngaphambili:
  • Okulandelayo:

    • AN002_Ukucocwa kweeNdibaniselwano zeAlkaline yiSepaFlash™ Alumina Cartridges
      AN002_Ukucocwa kweeNdibaniselwano zeAlkaline yiSepaFlash™ Alumina Cartridges
    • SepaFlash ikholamu yeKhathalogu EN
      SepaFlash ikholamu yeKhathalogu EN
    Bhala umyalezo wakho apha kwaye uwuthumele kuthi