SepaFlash™ Uthotho oludityanisiweyo
Iikholamu ezidityanisiweyo ze-flash zechungechunge zenziwe ngeekhatriji ezifanayo kunye nochungechunge lwe-HP kodwa zipakishwe nge-UltraPure, umgangatho ophezulu okanye ophezulu we-silica edibeneyo. Olu luhlu lweemveliso zinokubonelela ngeendidi ezahlukeneyo ze-sorbents ukwanelisa ngcono iimfuno zabasebenzisi abohlukeneyo.
※ Ifumaneka kwiinkcukacha ezininzi ezahlukeneyo.
※ Uxinzelelo oluphuculweyo lulinganiswe ukuya kwi-400 psi.
※ Ukusetyenziswa kwakhona: amaxesha angama-20 (umyinge).
※ Indawo yoQoqosho yokulungiselela iHPLC.
※ Dibana neentlobo ngeentlobo zeemfuno zokucoca okuthile.
I-Ultra-pure irregular C18, 40-63 µm, 60 Å
(i-carbon content 17%, i-end-capping, indawo ephezulu ye-500 m2/g, umthamo wokulayisha 0.1–2%)
Inombolo yento | Ubungakanani beKholam | Ubungakanani beSampuli | Iiyunithi/Ibhokisi | Inqanaba lokuHamba (mL/min) | Ubude beCartridge (mm) | ICartridge ID (mm) | Max. Uxinzelelo (psi/bar) |
SW-5201-004-IR | 5.9 g | 5.9 mg-118 mg | 2 | 10–20 | 113.8 | 12.4 | 400/27.5 |
SW-5201-012-IR | 23 g | 23mg–0.46g | 1 | 15–30 | 134.8 | 21.4 | 400/27.5 |
SW-5201-025-IR | 38 g | 38 mg–0.76 g | 1 | 15–30 | 184 | 21.4 | 400/27.5 |
SW-5201-040-IR | 55 g | 55 mg–1.1 g | 1 | 20–40 | 184.4 | 26.7 | 400/27.5 |
SW-5201-080-IR | 122 g | 122 mg–2.5 g | 1 | 30–60 | 257.4 | 31.2 | 350/24.0 |
SW-5201-120-IR | 180 g | 180 mg–3.6 g | 1 | 40–80 | 261.5 | 38.6 | 300/20.7 |
SW-5201-220-IR | 340 g | 340 mg–6.8 g | 1 | 50–100 | 223.5 | 61.4 | 300/20.7 |
SW-5201-330-IR | 475 g | 475 mg–9.5 g | 1 | 50–100 | 280.2 | 61.4 | 250/17.2 |
※ Iyahambelana nazo zonke iinkqubo zekhromatografi kwimarike.
I-Ultra-pure irregular C18, 40-63 µm, 90 Å
(i-carbon content 15%, i-end-capping, indawo ephezulu ye-400 m2/g, umthamo wokulayisha 0.1–2%)
Inombolo yento | Ubungakanani beKholam | Ubungakanani beSampuli | Iiyunithi/Ibhokisi | Inqanaba lokuHamba (mL/min) | Ubude beCartridge (mm) | ICartridge ID (mm) | Max. Uxinzelelo (psi/bar) |
SW-5211-004-IR | 5.2 g | 5.2 mg–104 mg | 2 | 10–20 | 113.8 | 12.4 | 400/27.5 |
SW-5211-012-IR | 20 g | 20 mg–0.40 g | 1 | 15–30 | 134.8 | 21.4 | 400/27.5 |
SW-5211-025-IR | 33 g | 33 mg–0.66 g | 1 | 15–30 | 184 | 21.4 | 400/27.5 |
SW-5211-040-IR | 48 g | 48 mg–0.96 g | 1 | 20–40 | 184.4 | 26.7 | 400/27.5 |
SW-5211-080-IR | 105 g | 105 mg–2.1 g | 1 | 30–60 | 257.4 | 31.2 | 350/24.0 |
SW-5211-120-IR | 155 g | 155 mg–3.1 g | 1 | 40–80 | 261.5 | 38.6 | 300/20.7 |
SW-5211-220-IR | 295 g | 295 mg–5.9 g | 1 | 50–100 | 223.5 | 61.4 | 300/20.7 |
SW-5211-330-IR | 420 g | 420 mg–8.4 g | 1 | 50–100 | 280.2 | 61.4 | 250/17.2 |
※ Iyahambelana nazo zonke iinkqubo zekhromatografi kwimarike.
Ultra-pure spherical C18, 40-60 µm, 120 Å
(i-carbon content 17%, i-end-capping, indawo ephezulu ye-300 m2 / g, umthamo wokulayisha 0.1-1.5%)
Inombolo yento | Ubungakanani beKholam | Ubungakanani beSampuli | Iiyunithi/Ibhokisi | Inqanaba lokuHamba (mL/min) | Ubude beCartridge (mm) | ICartridge ID (mm) | Max. Uxinzelelo (psi/bar) |
SW-5231-004-SP | 4.5 g | 4.5 mg-68 mg | 2 | 10–20 | 113.8 | 12.4 | 400/27.5 |
SW-5231-012-SP | 18 g | 18 mg–0.27 g | 1 | 15–30 | 134.8 | 21.4 | 400/27.5 |
SW-5231-025-SP | 28 g | 28 mg–0.42 g | 1 | 15–30 | 184 | 21.4 | 400/27.5 |
SW-5231-040-SP | 40 g | 40 mg-0.60 g | 1 | 20–40 | 184.4 | 26.7 | 400/27.5 |
SW-5231-080-SP | 90 g | 90 mg–1.35 g | 1 | 30–60 | 257.4 | 31.2 | 350/24.0 |
SW-5231-120-SP | 130 g | 130 mg–1.95 g | 1 | 40–80 | 261.5 | 38.6 | 300/20.7 |
SW-5231-220-SP | 245 g | 245 mg–3.68 g | 1 | 50–100 | 223.5 | 61.4 | 300/20.7 |
SW-5231-330-SP | 350 g | 350 mg–5.25 g | 1 | 50–100 | 280.2 | 61.4 | 250/17.2 |
※ Iyahambelana nazo zonke iinkqubo zekhromatografi kwimarike.
Umgangatho ophezulu we-Spherical C18, 30-50 µm, 120 Å
(i-carbon content 17%, i-end-capping, indawo ephezulu ye-300 m2/g, umthamo wokulayisha 0.1–2%)
Inombolo yento | Ubungakanani beKholam | Ubungakanani beSampuli | Iiyunithi/Ibhokisi | Inqanaba lokuHamba (mL/min) | Ubude beCartridge (mm) | ICartridge ID (mm) | Max. Uxinzelelo (psi/bar) |
SW-5232-004-SP | 4.3 g | 4.3 mg-86 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5232-012-SP | 16 g | 16 mg–0.32 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5232-025-SP | 26 g | 26 mg–0.52 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5232-040-SP | 39 g | 39 mg–0.78 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5232-080-SP | 85 g | 85 mg–1.7 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5232-120-SP | 125 g | 125 mg–2.5 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5232-220-SP | 240 g | 240 mg–4.8 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5232-330-SP | 335 g | 335 mg–6.7 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ Iyahambelana nazo zonke iinkqubo zekhromatografi kwimarike.
Ultra-pure spherical C18, 40-75 µm, 100 Å
(i-carbon content 17%, i-end-capping, indawo ephezulu ye-300 m2/g, umthamo wokulayisha 0.1–1.5%)
Inombolo yento | Ubungakanani beKholam | Ubungakanani beSampuli | Iiyunithi/Ibhokisi | Inqanaba lokuHamba (mL/min) | Ubude beCartridge (mm) | ICartridge ID (mm) | Max. Uxinzelelo (psi/bar) |
SW-5221-004-SP | 4.6 g | 4.6 mg-69 mg | 2 | 10–20 | 113.8 | 12.4 | 400/27.5 |
SW-5221-012-SP | 18 g | 18 mg–0.27 g | 1 | 15–30 | 134.8 | 21.4 | 400/27.5 |
SW-5221-025-SP | 30 g | 30 mg–0.45 g | 1 | 15–30 | 184 | 21.4 | 400/27.5 |
SW-5221-040-SP | 43 g | 43 mg–0.65 g | 1 | 20–40 | 184.4 | 26.7 | 400/27.5 |
SW-5221-080-SP | 95 g | 95 mg–1.43 g | 1 | 30–60 | 257.4 | 31.2 | 350/24.0 |
I-SW-5221-120-SP | 142 g | 142 mg–2.13 g | 1 | 40–80 | 261.5 | 38.6 | 300/20.7 |
SW-5221-220-SP | 265 g | 265 mg–3.98 g | 1 | 50–100 | 223.5 | 61.4 | 300/20.7 |
SW-5221-330-SP | 385 g | 385 mg–5.78 g | 1 | 50–100 | 280.2 | 61.4 | 250/17.2 |
※ Iyahambelana nazo zonke iinkqubo zekhromatografi kwimarike.
Umgangatho ophezulu we-Spherical C18, 20-45 µm, 100 Å
(i-carbon content 17%, i-end-capping, indawo ephezulu ye-320 m2/g, umthamo wokulayisha 0.1–2%)
Inombolo yento | Ubungakanani beKholam | Ubungakanani beSampuli | Iiyunithi/Ibhokisi | Inqanaba lokuHamba (mL/min) | Ubude beCartridge (mm) | ICartridge ID (mm) | Max. Uxinzelelo (psi/bar) |
SW-5222-004-SP | 5.4 g | 5.4 mg–108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5222-012-SP | 20 g | 20 mg–0.40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5222-025-SP | 33 g | 33 mg–0.66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5222-040-SP | 48 g | 48 mg–0.96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5222-080-SP | 105 g | 105 mg–2.1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
I-SW-5222-120-SP | 155 g | 155 mg–3.1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
I-SW-5222-220-SP | 300 g | 300 mg–6.0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5222-330-SP | 420 g | 420 mg–8.4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ Iyahambelana nazo zonke iinkqubo zekhromatografi kwimarike.
Umgangatho ophezulu we-Spherical C18(AQ), 20-45 µm, 100 Å (iMveliso ENTSHA)
(i-carbon content 10%, i-end-capping, indawo ephezulu ye-320 m2/g, umthamo wokulayisha 0.1–2%)
Inombolo yento | Ubungakanani beKholam | Ubungakanani beSampuli | Iiyunithi/Ibhokisi | Inqanaba lokuHamba (mL/min) | Ubude beCartridge (mm) | ICartridge ID (mm) | Max. Uxinzelelo (psi/bar) |
SW-5222-004-SP(AQ) | 5.4 g | 5.4 mg–108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
I-SW-5222-012-SP(AQ) | 20 g | 20 mg–0.40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
I-SW-5222-025-SP(AQ) | 33 g | 33 mg–0.66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
I-SW-5222-040-SP(AQ) | 48 g | 48 mg–0.96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
I-SW-5222-080-SP(AQ) | 105 g | 105 mg–2.1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
I-SW-5222-120-SP(AQ) | 155 g | 155 mg–3.1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
I-SW-5222-220-SP(AQ) | 300 g | 300 mg–6.0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
I-SW-5222-330-SP(AQ) | 420 g | 420 mg–8.4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ Iyahambelana nazo zonke iinkqubo zekhromatografi kwimarike.
Umgangatho ophezulu we-Spherical C18, 15 µm, 100 Å
(i-carbon content 17%, i-end-capping, indawo ephezulu ye-320 m2/g, umthamo wokulayisha 0.1–2%)
Inombolo yento | Ubungakanani beKholam | Ubungakanani beSampuli | Iiyunithi/Ibhokisi | Inqanaba lokuHamba (mL/min) | Ubude beCartridge (mm) | ICartridge ID (mm) | Max. Uxinzelelo (psi/bar) |
SW-5223-004-SP | 5.4 g | 5.4 mg–108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5223-012-SP | 20 g | 20 mg–0.40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5223-025-SP | 33 g | 33 mg–0.66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5223-040-SP | 48 g | 48 mg–0.96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5223-080-SP | 105 g | 105 mg–2.1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5223-120-SP | 155 g | 155 mg–3.1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5223-220-SP | 290 g | 290 mg–5.8 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5223-330-SP | 410 g | 410 mg–8.2 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ Iyahambelana nazo zonke iinkqubo zekhromatografi kwimarike.
Umgangatho ophezulu we-CN engqukuva, 20-45 µm, 100 Å
(i-carbon content 5.5%, i-end-capping, indawo ephezulu ye-320 m2/g, umthamo wokulayisha 0.1–2%)
Inombolo yento | Ubungakanani beKholam | Ubungakanani beSampuli | Iiyunithi/Ibhokisi | Inqanaba lokuHamba (mL/min) | Ubude beCartridge (mm) | ICartridge ID (mm) | Max. Uxinzelelo (psi/bar) |
SW-5322-004-SP | 5.4 g | 5.4 mg–108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5322-012-SP | 20 g | 20 mg–0.40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5322-025-SP | 33 g | 33 mg–0.66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5322-040-SP | 48 g | 48 mg–0.96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5322-080-SP | 105 g | 105 mg–2.1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5322-120-SP | 155 g | 155 mg–3.1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5322-220-SP | 300 g | 300 mg–6.0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5322-330-SP | 420 g | 420 mg–8.4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ Iyahambelana nazo zonke iinkqubo zekhromatografi kwimarike.
Umgangatho ophezulu we-Spherical C4, 20-45 µm, 100 Å
(i-carbon content 5.8%, i-end-capping, indawo ephezulu ye-320 m2/g, umthamo wokulayisha 0.1–2%)
Inombolo yento | Ubungakanani beKholam | Ubungakanani beSampuli | Iiyunithi/Ibhokisi | Inqanaba lokuHamba (mL/min) | Ubude beCartridge (mm) | ICartridge ID (mm) | Max. Uxinzelelo (psi/bar) |
SW-5422-004-SP | 5.4 g | 5.4 mg–108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5422-012-SP | 20 g | 20 mg–0.40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5422-025-SP | 33 g | 33 mg–0.66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5422-040-SP | 48 g | 48 mg–0.96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5422-080-SP | 105 g | 105 mg–2.1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
I-SW-5422-120-SP | 155 g | 155 mg–3.1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5422-220-SP | 300 g | 300 mg–6.0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5422-330-SP | 420 g | 420 mg–8.4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ Iyahambelana nazo zonke iinkqubo zekhromatografi kwimarike.
Umgangatho ophezulu we-ARG ongqukuva, 20-45 µm, 100 Å (iMveliso ENTSHA)
(i-carbon content 8%, i-end-capping, indawo ephezulu ye-320 m2/g, umthamo wokulayisha 0.1–2%)
Inombolo yento | Ubungakanani beKholam | Ubungakanani beSampuli | Iiyunithi/Ibhokisi | Inqanaba lokuHamba (mL/min) | Ubude beCartridge (mm) | ICartridge ID (mm) | Max. Uxinzelelo (psi/bar) |
SW-5622-004-SP | 5.4 g | 5.4 mg–108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
I-SW-5622-012-SP | 20 g | 20 mg–0.40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
I-SW-5622-025-SP | 33 g | 33 mg–0.66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5622-040-SP | 48 g | 48 mg–0.96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
I-SW-5622-080-SP | 105 g | 105 mg–2.1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
I-SW-5622-120-SP | 155 g | 155 mg–3.1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
I-SW-5622-220-SP | 300 g | 300 mg–6.0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5622-330-SP | 420 g | 420 mg–8.4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ Iyahambelana nazo zonke iinkqubo zekhromatografi kwimarike.
Umgangatho ophezulu we-Spherical C8, 20-45 µm, 100 Å
(i-carbon content 7%, i-end-capping, indawo ephezulu ye-320 m2/g, umthamo wokulayisha 0.1–2%)
Inombolo yento | Ubungakanani beKholam | Ubungakanani beSampuli | Iiyunithi/Ibhokisi | Inqanaba lokuHamba (mL/min) | Ubude beCartridge (mm) | ICartridge ID (mm) | Max. Uxinzelelo (psi/bar) |
SW-5822-004-SP | 5.4 g | 5.4 mg–108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5822-012-SP | 20 g | 20 mg–0.40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5822-025-SP | 33 g | 33 mg–0.66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5822-040-SP | 48 g | 48 mg–0.96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5822-080-SP | 105 g | 105 mg–2.1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
I-SW-5822-120-SP | 155 g | 155 mg–3.1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5822-220-SP | 300 g | 300 mg–6.0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5822-330-SP | 420 g | 420 mg–8.4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ Iyahambelana nazo zonke iinkqubo zekhromatografi kwimarike.
Umgangatho ophezulu we-Spherical C8(AQ), 20-45 µm, 100 Å (iMveliso ENTSHA)
(i-carbon content 7%, i-end-capping, indawo ephezulu ye-320 m2/g, umthamo wokulayisha 0.1–2%)
Inombolo yento | Ubungakanani beKholam | Ubungakanani beSampuli | Iiyunithi/Ibhokisi | Inqanaba lokuHamba (mL/min) | Ubude beCartridge (mm) | ICartridge ID (mm) | Max. Uxinzelelo (psi/bar) |
SW-5822-004-SP(AQ) | 5.4 g | 5.4 mg–108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
I-SW-5822-012-SP(AQ) | 20 g | 20 mg–0.40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
I-SW-5822-025-SP(AQ) | 33 g | 33 mg–0.66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
I-SW-5822-040-SP(AQ) | 48 g | 48 mg–0.96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
I-SW-5822-080-SP(AQ) | 105 g | 105 mg–2.1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
I-SW-5822-120-SP(AQ) | 155 g | 155 mg–3.1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
I-SW-5822-220-SP(AQ) | 300 g | 300 mg–6.0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
I-SW-5822-330-SP(AQ) | 420 g | 420 mg–8.4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ Iyahambelana nazo zonke iinkqubo zekhromatografi kwimarike.
IDiol engqukuva esebenza kakuhle kakhulu, 20-45 µm, 100 Å
(i-carbon content 5%, i-end-capping, indawo ephezulu ye-320 m2/g, umthamo wokulayisha 0.1–2%)
Inombolo yento | Ubungakanani beKholam | Ubungakanani beSampuli | Iiyunithi/Ibhokisi | Inqanaba lokuHamba (mL/min) | Ubude beCartridge (mm) | ICartridge ID (mm) | Max. Uxinzelelo (psi/bar) |
SW-5922-004-SP | 5.4 g | 5.4 mg–108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
I-SW-5922-012-SP | 20 g | 20 mg–0.40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5922-025-SP | 33 g | 33 mg–0.66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5922-040-SP | 48 g | 48 mg–0.96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
I-SW-5922-080-SP | 105 g | 105 mg–2.1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
I-SW-5922-120-SP | 155 g | 155 mg–3.1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
I-SW-5922-220-SP | 300 g | 300 mg–6.0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5922-330-SP | 420 g | 420 mg–8.4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ Iyahambelana nazo zonke iinkqubo zekhromatografi kwimarike.
Phenyl esebenza kakuhle kakhulu engqukuva, 20-45 µm, 100 Å
(i-carbon content 10%, i-end-capping, indawo ephezulu ye-320 m2/g, umthamo wokulayisha 0.1–2%)
Inombolo yento | Ubungakanani beKholam | Ubungakanani beSampuli | Iiyunithi/Ibhokisi | Inqanaba lokuHamba (mL/min) | Ubude beCartridge (mm) | ICartridge ID (mm) | Max. Uxinzelelo (psi/bar) |
SW-5B22-004-SP | 5.4 g | 5.4 mg–108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5B22-012-SP | 20 g | 20 mg–0.40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5B22-025-SP | 33 g | 33 mg–0.66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5B22-040-SP | 48 g | 48 mg–0.96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5B22-080-SP | 105 g | 105 mg–2.1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5B22-120-SP | 155 g | 155 mg–3.1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5B22-220-SP | 300 g | 300 mg–6.0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5B22-330-SP | 420 g | 420 mg–8.4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ Iyahambelana nazo zonke iinkqubo zekhromatografi kwimarike.
Umgangatho ophezulu wephenyl-Hexyl, 20-45 µm, 100 Å
(i-carbon content 10%, i-end-capping, indawo ephezulu ye-320 m2/g, umthamo wokulayisha 0.1–2%)
Inombolo yento | Ubungakanani beKholam | Ubungakanani beSampuli | Iiyunithi/Ibhokisi | Inqanaba lokuHamba (mL/min) | Ubude beCartridge (mm) | ICartridge ID (mm) | Max. Uxinzelelo (psi/bar) |
SW-5C22-004-SP | 5.4 g | 5.4 mg–108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
I-SW-5C22-012-SP | 20 g | 20 mg–0.40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
I-SW-5C22-025-SP | 33 g | 33 mg–0.66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5C22-040-SP | 48 g | 48 mg–0.96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5C22-080-SP | 105 g | 105 mg–2.1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
I-SW-5C22-120-SP | 155 g | 155 mg–3.1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
I-SW-5C22-220-SP | 300 g | 300 mg–6.0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5C22-330-SP | 420 g | 420 mg–8.4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ Iyahambelana nazo zonke iinkqubo zekhromatografi kwimarike.
I-Ultra-pure irregular NH2, 40-63 µm, 60 Å
(umxholo we-amino 1.3 mmol / g, i-end-capping, indawo ephezulu ye-500 m2/g, umthamo wokulayisha 0.1–2%)
Inombolo yento | Ubungakanani beKholam | Ubungakanani beSampuli | Iiyunithi/Ibhokisi | Inqanaba lokuHamba (mL/min) | Ubude beCartridge (mm) | ICartridge ID (mm) | Max. Uxinzelelo (psi/bar) |
SW-5501-004-IR | 5.9 g | 5.9 mg-118 mg | 2 | 10–20 | 113.8 | 12.4 | 400/27.5 |
SW-5501-012-IR | 23 g | 23 mg–0.46 g | 1 | 15–30 | 134.8 | 21.4 | 400/27.5 |
SW-5501-025-IR | 38 g | 38 mg–0.76 g | 1 | 15–30 | 184 | 21.4 | 400/27.5 |
SW-5501-040-IR | 55 g | 55 mg–1.1 g | 1 | 20–40 | 184.4 | 26.7 | 400/27.5 |
SW-5501-080-IR | 122 g | 122 mg–2.5 g | 1 | 30–60 | 257.4 | 31.2 | 350/24.0 |
SW-5501-120-IR | 180 g | 180 mg–3.6 g | 1 | 40–80 | 261.5 | 38.6 | 300/20.7 |
SW-5501-220-IR | 340 g | 340 mg–6.8 g | 1 | 50–100 | 223.5 | 61.4 | 300/20.7 |
SW-5501-330-IR | 475 g | 475 mg–9.5 g | 1 | 50–100 | 280.2 | 61.4 | 250/17.2 |
※ Iyahambelana nazo zonke iinkqubo zekhromatografi kwimarike.
I-Ultra-pure irregular SAX, 40-63 µm, 60 Å
(umxholo wekhabhoni i-8%, indawo ephezulu ye-500 m2/g, umthamo we-ion-exchange ≤ 0.26 meq/g)
Inombolo yento | Ubungakanani beKholam | Ubungakanani beSampuli | Iiyunithi/Ibhokisi | Inqanaba lokuHamba (mL/min) | Ubude beCartridge (mm) | ICartridge ID (mm) | Max. Uxinzelelo (psi/bar) |
SW-5001-004-IR | 5.9 g | ≤ 1.53 meq | 2 | 10–20 | 113.8 | 12.4 | 400/27.5 |
SW-5001-012-IR | 23 g | ≤ 5.98 meq | 1 | 15–30 | 134.8 | 21.4 | 400/27.5 |
SW-5001-025-IR | 38 g | ≤ 9.88 meq | 1 | 15–30 | 184 | 21.4 | 400/27.5 |
SW-5001-040-IR | 55 g | ≤ 14.30 meq | 1 | 20–40 | 184.4 | 26.7 | 400/27.5 |
SW-5001-080-IR | 122 g | ≤ 31.72 meq | 1 | 30–60 | 257.4 | 31.2 | 350/24.0 |
SW-5001-120-IR | 180 g | ≤ 46.80 meq | 1 | 40–80 | 261.5 | 38.6 | 300/20.7 |
SW-5001-220-IR | 340 g | ≤ 88.40 meq | 1 | 50–100 | 223.5 | 61.4 | 300/20.7 |
SW-5001-330-IR | 475 g | ≤ 123.50 meq | 1 | 50–100 | 280.2 | 61.4 | 250/17.2 |
※ Iyahambelana nazo zonke iinkqubo zekhromatografi kwimarike.
I-Ultra-pure irregular SCX, 40-63 µm, 60 Å
(umxholo wekhabhoni i-10%, indawo ephezulu ye-500 m2/g, umthamo we-ion-exchange ≤ 0.34 meq/g)
Inombolo yento | Ubungakanani beKholam | Ubungakanani beSampuli | Iiyunithi/Ibhokisi | Inqanaba lokuHamba (mL/min) | Ubude beCartridge (mm) | ICartridge ID (mm) | Max. Uxinzelelo (psi/bar) |
SW-5701-004-IR | 5.9 g | ≤ 2.01 meq | 2 | 10–20 | 113.8 | 12.4 | 400/27.5 |
SW-5701-012-IR | 23 g | ≤ 7.82 meq | 1 | 15–30 | 134.8 | 21.4 | 400/27.5 |
SW-5701-025-IR | 38 g | ≤ 12.92 meq | 1 | 15–30 | 184 | 21.4 | 400/27.5 |
SW-5701-040-IR | 55 g | ≤ 18.70 meq | 1 | 20–40 | 184.4 | 26.7 | 400/27.5 |
SW-5701-080-IR | 122 g | ≤ 41.48 meq | 1 | 30–60 | 257.4 | 31.2 | 350/24.0 |
SW-5701-120-IR | 180 g | ≤ 61.20 meq | 1 | 40–80 | 261.5 | 38.6 | 300/20.7 |
SW-5701-220-IR | 340 g | ≤ 115.60 meq | 1 | 50–100 | 223.5 | 61.4 | 300/20.7 |
SW-5701-330-IR | 475 g | ≤ 161.50 meq | 1 | 50–100 | 280.2 | 61.4 | 250/17.2 |
※ Iyahambelana nazo zonke iinkqubo zekhromatografi kwimarike.
- AN001-Ukucocwa kweeNkomfa zeHydrophilic yiSepaFlash™ HILIC Cartridges
- AN003-Ukusetyenziswa kweSepaFlash™ HILIC Cartridges kwiSynthetic Intermediates Ukucoca
- I-AN004-Ukhetho lweSigaba seSelfowuni kwiSigaba esiHlehliweyo seChromatografi
- AN008-Uphononongo lweNdlela yoLungiselelo yokuNyusa ngeSepaFlash™ iSigaba esiBuyiselwayo seKholamu
- AN010-Ukusetyenziswa kweSepaFlash™ iSigaba esibuyiselwe umva iikhatriji kwiiSampulu eziNcinci kakhulu kunye nezinyibilikayo.
- AN014_UkuPhuculwa kweSigqibo ngokuFakwa kweKholam kunye nokuSetyenziswa kwayo
- AN015_Hydrophobic Phase Collapse, AQ Reversed Phase Chromatography Columns
- AN016_Ukusetyenziswa kwe-SepaFlash™ eqinile yoTshintsho lweCation yeKholamu yeChromatography ekuCocisweni kweeNdibaniselwano zealkaline
- AN017-Ukucocwa kweTaxus Extract ngomatshini weSepaBean™
- AN018_Ukusetyenziswa kweeKholamu zeC18AQ ekuCocokiseni iiPeptides zePolar ezinamandla
- AN019_Ukucocwa kobumdaka obuphezulu bePolar kwiAntibiotics yiC18AQ Columns
- I-AN020-Ukusetyenziswa kwe-SepaFlash ™, iiKholamu zeChromatography ze-Anion ezomeleleyo ekuCoconi iiKhowudi ezine-Acidic
- AN024_Ukusetyenziswa kweChromatography ye-Orthogonal yokuSungula i-Synthetic Pharmaceutical Intermediates
- AN026_Ukusetyenziswa kweCartridge ye-SepaFlash ye-HIC ARG yokuCoca iNdawo eyomeleleyo yePolar Thiazide
- I-AN027_SepaFlash™ i-HILIC ARG cartridge kunye nokuSetyenziswa kwayo ekuCocisweni kwe-Oligosaccharides
- AN028_IsiKhokelo soMsebenzisi sokuSebenzisa, ukuCoca kunye noGcino lwe-SepaFlash™eBonded iiKholamu zeFlash eziBond
- I-AN029_SepaFlash™C18AQ Cartridge kunye nokuSetyenziswa kwayo ekuCocisweni kweGlutamine Derivatives
- I-AN033_SepaFlash™ i-HILIC ARG Cartridge kunye nokuSetyenziswa kwayo ekuCocisweni kwe-Amino Acid Derivatives
- I-AN036_SepaFlash™C18AQ Ikhatriji kunye nokuSetyenziswa kwayo kwiSampuli yeDesalting
- I-AN-SS-003 Ukucocwa kweFacile ye-steric enkulu ekhethiweyo ye-bicyclic carbohydrates ngumatshini we-SepaBean™
- I-AN-SS-006 Ukwahlulwa kwe-CBD kunye ne-THC nge-SepaFlash™ iSpherical C18 Columns
- SepaFlash ikholamu yeKhathalogu EN