Wholesale Price Standard Flash Column - SepaFlash™ HP Series – Santai
Wholesale Price Standard Flash Column - SepaFlash™ HP Series – Santai Detail:
HP series flash columns are spin-welded and allow for higher pressure of up to 400 psi. Available adapter facilitates compatibility with any flash system on the market. This series provides Luer-Lok in and Luer-Lok out flexibility for convenient column stacking. When pre-packed with high-efficiency silica gel (irregular, 25-40 μm, 60 Å; spherical, 20-45 μm, 70 Å), this series presents an outstanding resolution over conventional flash cartridges.
※ Solid, one-piece polypropylene body with thick walls for safety
※ Freely choose irregular silica or spherical silica according to your personal preference
※ Markedly improved resolution and higher sample loading capability
※ Spherical silica provides improved performance without increasing the system backpressure
For spherical silica gel, strict quality controls from raw material to finished product ensures high lot-to-lot reproducibility and tightly controlled specifications.
※Consistency, reliability, reproducibility
※No contamination, lower backpressure
※Superior resolution
※Symmetrical peaks with no tailing
※Higher sample loading capacity
UltraPure irregular silica, 40−63 µm, 60 Å (surface area 500 m2 /g, pH 6.5–7.5, loading capacity 0.1–10%)
Item Number | Column Size | Sample Size(g) | Flow Rate(mL/min) | Cartridge Length (cm) | Cartridge ID (mm) | Max. Pressure(psi/bar) | Quantity per Box | |
Small | Big | |||||||
SW-5101-004 | 4 g | 4 mg–0.4 g | 15–40 | 113.8 | 12.4 | 400/27.5 | 24 | 120 |
SW-5101-012 | 12 g | 12 mg–1.2 g | 30–60 | 134.8 | 21.4 | 400/27.5 | 24 | 108 |
SW-5101-025 | 25 g | 25 mg–2.5 g | 30–60 | 184 | 21.4 | 400/27.5 | 18 | 72 |
SW-5101-040 | 40 g | 40 mg–4.0 g | 40–70 | 184.4 | 26.7 | 400/27.5 | 12 | 48 |
SW-5101-080 | 80 g | 80 mg–8.0 g | 50–100 | 257.4 | 31.2 | 350/24.0 | 10 | 20 |
SW-5101-120 | 120 g | 120 mg–12 g | 60–150 | 261.5 | 38.6 | 300/20.7 | 8 | 16 |
SW-5101-220 | 220 g | 220 mg–22 g | 80–220 | 223.5 | 61.4 | 300/20.7 | 4 | 8 |
SW-5101-330 | 330 g | 330 mg–33 g | 80–220 | 280.2 | 61.4 | 250/17.2 | 3 | 6 |
※ Compatible with all flash chromatography systems on the market.
High-efficiency irregular silica, 25−40 µm, 60 Å (surface area 500 m2 /g, pH 6.5–7.5, loading capacity 0.1–15%)
Item Number | Column Size | Sample Size(g) | Flow Rate(mL/min) | Cartridge Length (cm) | Cartridge ID (mm) | Max. Pressure(psi/bar) | Quantity per Box | |
Small | Big | |||||||
SW-5102-004 | 4 g | 4 mg–0.6 g | 15–30 | 113.8 | 12.4 | 400/27.5 | 24 | 120 |
SW-5102-012 | 12 g | 12 mg–1.8 g | 25–50 | 134.8 | 21.4 | 400/27.5 | 24 | 108 |
SW-5102-025 | 25 g | 25 mg–3.8 g | 25–50 | 184 | 21.4 | 400/27.5 | 18 | 72 |
SW-5102-040 | 40 g | 40 mg–6.0 g | 30–60 | 184.4 | 26.7 | 400/27.5 | 12 | 48 |
SW-5102-080 | 80 g | 80 mg–12 g | 40–80 | 257.4 | 31.2 | 350/24.0 | 10 | 20 |
SW-5102-120 | 120 g | 120 mg–18 g | 45–90 | 261.5 | 38.6 | 300/20.7 | 8 | 16 |
SW-5102-220 | 220 g | 220 mg–33 g | 60–120 | 223.5 | 61.4 | 300/20.7 | 4 | 8 |
SW-5102-330 | 330 g | 330 mg–50 g | 60–120 | 280.2 | 61.4 | 250/17.2 | 3 | 6 |
※ Compatible with all flash chromatography systems on the market.
UltraPure spherical silica, 40−75 µm, 70 Å (surface area 500 m2 /g, pH 6.0–8.0, loading capacity 0.1–10%)
Item Number | Column Size | Sample Size(g) | Flow Rate(mL/min) | Cartridge Length (cm) | Cartridge ID (mm) | Max. Pressure(psi/bar) | Quantity per Box | |
Small | Big | |||||||
SW-2101-004-SP | 4 g | 4 mg–0.4 g | 15–40 | 113.8 | 12.4 | 400/27.5 | 24 | 120 |
SW-2101-012-SP | 12 g | 12 mg–1.2 g | 30–60 | 134.8 | 21.4 | 400/27.5 | 24 | 108 |
SW-2101-025-SP | 25 g | 25 mg–2.5 g | 30–60 | 184 | 21.4 | 400/27.5 | 18 | 72 |
SW-2101-040-SP | 40 g | 40 mg–4.0 g | 40–70 | 184.4 | 26.7 | 400/27.5 | 12 | 48 |
SW-2101-080-SP | 80 g | 80 mg–8.0 g | 50–100 | 257.4 | 31.2 | 350/24.0 | 10 | 20 |
SW-2101-120-SP | 120 g | 120 mg–12 g | 60–150 | 261.5 | 38.6 | 300/20.7 | 8 | 16 |
SW-2101-220-SP | 220 g | 220 mg–22 g | 80–220 | 223.5 | 61.4 | 300/20.7 | 4 | 8 |
SW-2101-330-SP | 330 g | 330 mg–33 g | 80–220 | 280.2 | 61.4 | 250/17.2 | 3 | 6 |
※Compatible with all flash chromatography systems on the market.
High-efficiency spherical silica, 20−45 µm, 70 Å (surface area 500 m2 /g, pH 6.0–8.0, loading capacity 0.1–15%)
Item Number | Column Size | Sample Size(g) | Flow Rate(mL/min) | Cartridge Length (cm) | Cartridge ID (mm) | Max. Pressure(psi/bar) | Quantity per Box |
SW-2102-004-SP | 4 g | 4 mg–0.6 g | 15–30 | 113.8 | 12.4 | 400/27.5 | 24 |
SW-2102-012-SP | 12 g | 12 mg–1.8 g | 25–50 | 134.8 | 21.4 | 400/27.5 | 24 |
SW-2102-025-SP | 25 g | 25 mg–3.8 g | 25–50 | 184 | 21.4 | 400/27.5 | 18 |
SW-2102-040-SP | 40 g | 40 mg–6.0 g | 30–60 | 184.4 | 26.7 | 400/27.5 | 12 |
SW-2102-080-SP | 80 g | 80 mg–12 g | 40–80 | 257.4 | 31.2 | 350/24.0 | 10 |
SW-2102-120-SP | 120 g | 120 mg–18 g | 45–90 | 261.5 | 38.6 | 300/20.7 | 8 |
SW-2102-220-SP | 220 g | 220 mg–33 g | 60–120 | 223.5 | 61.4 | 300/20.7 | 4 |
SW-2102-330-SP | 330 g | 330 mg–50 g | 60–120 | 280.2 | 61.4 | 250/17.2 | 3 |
※Compatible with all flash chromatography systems on the market.
Purification of compounds that are difficult to separate by flash chromatography (ΔRf ≤ 0.2 between spots on TLC) often results in additional steps such as subsequent purification by preparative scale HPLC. It is possible to reduce the amount of additional work required for purification by simply stacking several prepacked SepaFlash™ columns end to end on a flash chromatography system.
In liquid chromatography, chemical species are separated on the basis of their differences in velocity as they move through the column. Increasing column length can significantly increase resolution. By stacking columns end to end the length to diameter (L to D) ratio is increased so that no major changes to the media and solvent system are necessary. Often this increased L to D is sufficient to provide successful separation of difficult mixtures due to close compounds retention time that is not obtained on a single column. The data illustrates the linear relationship between the resolution and overall column length.
The Highest Purification Performance Available
HP series flash columns are precisely manufactured with high-capacity silica gel, and deliver the highest purification performance. The high-capacity spherical silica has 40% higher surface area, doubling the loading capacity of lower surface area silica.
※ High-capacity silica with 40% more surface area.
※ Higher loading means smaller, faster and cheaper cartridges can be used for any separation.
※ Less solvent required.
※ The highest peak resolution.
High-capacity spherical silica, 25 µm, 50 Å (surface area 700 m2 /g, pH 5.0–8.0, loading capacity 0.1–30%)
Item Number | Column Size | Sample Size(g) | Flow Rate(mL/min) | Cartridge Length (cm) | Cartridge ID (mm) | Max. Pressure(psi/bar) | Quantity per Box | |
Small | Big | |||||||
SW-2102-004-SP(H) | 4 g | 4 mg–1.2 g | 15–30 | 113.8 | 12.4 | 400/27.5 | 24 | 120 |
SW-2102-012-SP(H) | 12 g | 12 mg–3.6 g | 25–50 | 134.8 | 21.4 | 400/27.5 | 24 | 108 |
SW-2102-025-SP(H) | 25 g | 25 mg–7.5 g | 25–50 | 184 | 21.4 | 400/27.5 | 18 | 72 |
SW-2102-040-SP(H) | 40 g | 40 mg–12 g | 30–60 | 184.4 | 26.7 | 400/27.5 | 12 | 48 |
SW-2102-080-SP(H) | 80 g | 80 mg–24 g | 40–80 | 257.4 | 31.2 | 350/24.0 | 10 | 20 |
SW-2102-120-SP(H) | 120 g | 120 mg–36 g | 45–90 | 261.5 | 38.6 | 300/20.7 | 8 | 16 |
SW-2102-220-SP(H) | 220 g | 220 mg–66 g | 60–120 | 223.5 | 61.4 | 300/20.7 | 4 | 8 |
SW-2102-330-SP(H) | 330 g | 330 mg–99 g | 60–120 | 280.2 | 61.4 | 250/17.2 | 3 | 6 |
※ Compatible with all flash chromatography systems on the market.
High-capacity spherical silica, 15 µm, 50 Å (NEW Product) (surface area 700 m2 /g, pH 5.0–8.0, loading capacity 0.1–30%)
Item Number | Column Size | Sample Size(g) | Flow Rate(mL/min) | Cartridge Length (cm) | Cartridge ID (mm) | Max. Pressure(psi/bar) | Quantity per Box | |
Small | Big | |||||||
SW-2103-004-SP(H) | 4 g | 4 mg–1.2 g | 10–15 | 113.8 | 12.4 | 400/27.5 | 24 | 120 |
SW-2103-012-SP(H) | 12 g | 12 mg–3.6 g | 15–20 | 134.8 | 21.4 | 400/27.5 | 24 | 108 |
SW-2103-025-SP(H) | 25 g | 25 mg–7.5 g | 15–20 | 184 | 21.4 | 400/27.5 | 18 | 72 |
SW-2103-040-SP(H) | 40 g | 40 mg–12 g | 20–30 | 184.4 | 26.7 | 400/27.5 | 12 | 48 |
SW-2103-080-SP(H) | 80 g | 80 mg–24 g | 30–40 | 257.4 | 31.2 | 350/24.0 | 10 | 20 |
SW-2103-120-SP(H) | 120 g | 120 mg–36 g | 35–45 | 261.5 | 38.6 | 300/20.7 | 8 | 16 |
SW-2103-220-SP(H) | 220 g | 220 mg–66 g | 50–65 | 223.5 | 61.4 | 300/20.7 | 4 | 8 |
SW-2103-330-SP(H) | 330 g | 330 mg–99 g | 50–65 | 280.2 | 61.4 | 250/17.2 | 3 | 6 |
※ Compatible with all flash chromatography systems on the market.
Double Loading Capacity of SepaFlash™ Cartridges pre-packed with high-capacity silica gel (700 m2 /g for 50 Å pore size) delivers the highest purification performance. The high-capacity 25 µm or 15 µm spherical silica has 40% higher surface area, doubling the loading capacity of lower surface area silica. Santai evaluated the performance of the SepaFlash™ columns compared to two well-known brands. Results show SepaFlash™ outperforms the competitors.
Product detail pictures:
Related Product Guide:
We support our purchasers with ideal premium quality products and substantial level company. Becoming the specialist manufacturer in this sector, we've acquired rich practical working experience in producing and managing for Wholesale Price Standard Flash Column - SepaFlash™ HP Series – Santai , The product will supply to all over the world, such as: Chile, America, Colombia, They're durable modeling and promoting well all over the world. Under no circumstances disappearing key functions in a brief time, it's a should for you personally of fantastic quality. Guided by the principle of Prudence, Efficiency, Union and Innovation. the business make an awesome efforts to expand its international trade, raise its enterprise. rofit and improve its export scale. We are confident that we'll have a vibrant prospect and to be distributed all over the world in the years to come.
By Chris from Porto - 2018.09.19 18:37
Company director has very rich management experience and strict attitude, sales staff are warm and cheerful, technical staff are professional and responsible,so we have no worry about product,a nice manufacturer.
By Mignon from Bulgaria - 2017.11.12 12:31