Wholesale Price Standard Flash Column - SepaFlash™ HP Series – Santai

Wholesale Price Standard Flash Column - SepaFlash™ HP Series – Santai

Short Description:


Product Detail

Application

Video

catalogue

Related Video

Feedback (2)

abide by the contract", conforms on the market requirement, joins from the market competition by its good quality likewise as provides more comprehensive and superb support for customers to let them become large winner. The pursue of the company, is definitely the clients' pleasure for 60G Flash Column, Chemistry, Evaporative Light Scattering Detector, We welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!
Wholesale Price Standard Flash Column - SepaFlash™ HP Series – Santai Detail:

HP series flash columns are spin-welded and allow for higher pressure of up to 400 psi. Available adapter facilitates compatibility with any flash system on the market. This series provides Luer-Lok in and Luer-Lok out flexibility for convenient column stacking. When pre-packed with high-efficiency silica gel (irregular, 25-40 μm, 60 Å; spherical, 20-45 μm, 70 Å), this series presents an outstanding resolution over conventional flash cartridges.

※ Solid, one-piece polypropylene body with thick walls for safety
※ Freely choose irregular silica or spherical silica according to your personal preference
※ Markedly improved resolution and higher sample loading capability
※ Spherical silica provides improved performance without increasing the system backpressure

For spherical silica gel, strict quality controls from raw material to finished product ensures high lot-to-lot reproducibility and tightly controlled specifications.

※Consistency, reliability, reproducibility
※No contamination, lower backpressure 
※Superior resolution
※Symmetrical peaks with no tailing
※Higher sample loading capacity

spherical

UltraPure irregular silica, 40−63 µm, 60 Å (surface area 500 m2 /g, pH 6.5–7.5, loading capacity 0.1–10%)

Item Number Column Size Sample Size(g) Flow Rate(mL/min) Cartridge Length (cm) Cartridge ID (mm) Max. Pressure(psi/bar) Quantity per Box
Small Big
SW-5101-004 4 g 4 mg–0.4 g 15–40 113.8 12.4 400/27.5 24 120
SW-5101-012 12 g 12 mg–1.2 g 30–60 134.8 21.4 400/27.5 24 108
SW-5101-025 25 g 25 mg–2.5 g 30–60 184 21.4 400/27.5 18 72
SW-5101-040 40 g 40 mg–4.0 g 40–70 184.4 26.7 400/27.5 12 48
SW-5101-080 80 g 80 mg–8.0 g 50–100 257.4 31.2 350/24.0 10 20
SW-5101-120 120 g 120 mg–12 g 60–150 261.5 38.6 300/20.7 8 16
SW-5101-220 220 g 220 mg–22 g 80–220 223.5 61.4 300/20.7 4 8
SW-5101-330 330 g 330 mg–33 g 80–220 280.2 61.4 250/17.2 3 6

※ Compatible with all flash chromatography systems on the market.

High-efficiency irregular silica, 25−40 µm, 60 Å (surface area 500 m2 /g, pH 6.5–7.5, loading capacity 0.1–15%)

Item Number Column Size Sample Size(g) Flow Rate(mL/min) Cartridge Length (cm) Cartridge ID (mm) Max. Pressure(psi/bar) Quantity per Box
Small Big
SW-5102-004 4 g 4 mg–0.6 g 15–30 113.8 12.4 400/27.5 24 120
SW-5102-012 12 g 12 mg–1.8 g 25–50 134.8 21.4 400/27.5 24 108
SW-5102-025 25 g 25 mg–3.8 g 25–50 184 21.4 400/27.5 18 72
SW-5102-040 40 g 40 mg–6.0 g 30–60 184.4 26.7 400/27.5 12 48
SW-5102-080 80 g 80 mg–12 g 40–80 257.4 31.2 350/24.0 10 20
SW-5102-120 120 g 120 mg–18 g 45–90 261.5 38.6 300/20.7 8 16
SW-5102-220 220 g 220 mg–33 g 60–120 223.5 61.4 300/20.7 4 8
SW-5102-330 330 g 330 mg–50 g 60–120 280.2 61.4 250/17.2 3 6

※ Compatible with all flash chromatography systems on the market.

UltraPure spherical silica, 40−75 µm, 70 Å (surface area 500 m2 /g, pH 6.0–8.0, loading capacity 0.1–10%)

Item Number Column Size Sample Size(g) Flow Rate(mL/min) Cartridge Length (cm) Cartridge ID (mm) Max. Pressure(psi/bar) Quantity per Box
Small Big
SW-2101-004-SP 4 g 4 mg–0.4 g 15–40 113.8 12.4 400/27.5 24 120
SW-2101-012-SP 12 g 12 mg–1.2 g 30–60 134.8 21.4 400/27.5 24 108
SW-2101-025-SP 25 g 25 mg–2.5 g 30–60 184 21.4 400/27.5 18 72
SW-2101-040-SP 40 g 40 mg–4.0 g 40–70 184.4 26.7 400/27.5 12 48
SW-2101-080-SP 80 g 80 mg–8.0 g 50–100 257.4 31.2 350/24.0 10 20
SW-2101-120-SP 120 g 120 mg–12 g 60–150 261.5 38.6 300/20.7 8 16
SW-2101-220-SP 220 g 220 mg–22 g 80–220 223.5 61.4 300/20.7 4 8
SW-2101-330-SP 330 g 330 mg–33 g 80–220 280.2 61.4 250/17.2 3 6

※Compatible with all flash chromatography systems on the market.

High-efficiency spherical silica, 20−45 µm, 70 Å (surface area 500 m2 /g, pH 6.0–8.0, loading capacity 0.1–15%)

Item Number Column Size Sample Size(g) Flow Rate(mL/min) Cartridge Length (cm) Cartridge ID (mm) Max. Pressure(psi/bar) Quantity per Box
SW-2102-004-SP 4 g 4 mg–0.6 g 15–30 113.8 12.4 400/27.5 24
SW-2102-012-SP 12 g 12 mg–1.8 g 25–50 134.8 21.4 400/27.5 24
SW-2102-025-SP 25 g 25 mg–3.8 g 25–50 184 21.4 400/27.5 18
SW-2102-040-SP 40 g 40 mg–6.0 g 30–60 184.4 26.7 400/27.5 12
SW-2102-080-SP 80 g 80 mg–12 g 40–80 257.4 31.2 350/24.0 10
SW-2102-120-SP 120 g 120 mg–18 g 45–90 261.5 38.6 300/20.7 8
SW-2102-220-SP 220 g 220 mg–33 g 60–120 223.5 61.4 300/20.7 4
SW-2102-330-SP 330 g 330 mg–50 g 60–120 280.2 61.4 250/17.2 3

※Compatible with all flash chromatography systems on the market.

Purification of compounds that are difficult to separate by flash chromatography (ΔRf ≤ 0.2 between spots on TLC) often results in additional steps such as subsequent purification by preparative scale HPLC. It is possible to reduce the amount of additional work required for purification by simply stacking several prepacked SepaFlash™ columns end to end on a flash chromatography system.

In liquid chromatography, chemical species are separated on the basis of their differences in velocity as they move through the column. Increasing column length can significantly increase resolution. By stacking columns end to end the length to diameter (L to D) ratio is increased so that no major changes to the media and solvent system are necessary. Often this increased L to D is sufficient to provide successful separation of difficult mixtures due to close compounds retention time that is not obtained on a single column. The data illustrates the linear relationship between the resolution and overall column length.

HP1
HP

The Highest Purification Performance Available
HP series flash columns are precisely manufactured with high-capacity silica gel, and deliver the highest purification performance. The high-capacity spherical silica has 40% higher surface area, doubling the loading capacity of lower surface area silica.
※ High-capacity silica with 40% more surface area.
※ Higher loading means smaller, faster and cheaper cartridges can be used for any separation.
※ Less solvent required.
※ The highest peak resolution.

High-capacity spherical silica, 25 µm, 50 Å (surface area 700 m2 /g, pH 5.0–8.0, loading capacity 0.1–30%)

Item Number Column Size Sample Size(g) Flow Rate(mL/min) Cartridge Length (cm) Cartridge ID (mm) Max. Pressure(psi/bar) Quantity per Box
Small Big
SW-2102-004-SP(H) 4 g 4 mg–1.2 g 15–30 113.8 12.4 400/27.5 24 120
SW-2102-012-SP(H) 12 g 12 mg–3.6 g 25–50 134.8 21.4 400/27.5 24 108
SW-2102-025-SP(H) 25 g 25 mg–7.5 g 25–50 184 21.4 400/27.5 18 72
SW-2102-040-SP(H) 40 g 40 mg–12 g 30–60 184.4 26.7 400/27.5 12 48
SW-2102-080-SP(H) 80 g 80 mg–24 g 40–80 257.4 31.2 350/24.0 10 20
SW-2102-120-SP(H) 120 g 120 mg–36 g 45–90 261.5 38.6 300/20.7 8 16
SW-2102-220-SP(H) 220 g 220 mg–66 g 60–120 223.5 61.4 300/20.7 4 8
SW-2102-330-SP(H) 330 g 330 mg–99 g 60–120 280.2 61.4 250/17.2 3 6

※ Compatible with all flash chromatography systems on the market.

High-capacity spherical silica, 15 µm, 50 Å (NEW Product) (surface area 700 m2 /g, pH 5.0–8.0, loading capacity 0.1–30%)

Item Number Column Size Sample Size(g) Flow Rate(mL/min) Cartridge Length (cm) Cartridge ID (mm) Max. Pressure(psi/bar) Quantity per Box
Small Big
SW-2103-004-SP(H) 4 g 4 mg–1.2 g 10–15 113.8 12.4 400/27.5 24 120
SW-2103-012-SP(H) 12 g 12 mg–3.6 g 15–20 134.8 21.4 400/27.5 24 108
SW-2103-025-SP(H) 25 g 25 mg–7.5 g 15–20 184 21.4 400/27.5 18 72
SW-2103-040-SP(H) 40 g 40 mg–12 g 20–30 184.4 26.7 400/27.5 12 48
SW-2103-080-SP(H) 80 g 80 mg–24 g 30–40 257.4 31.2 350/24.0 10 20
SW-2103-120-SP(H) 120 g 120 mg–36 g 35–45 261.5 38.6 300/20.7 8 16
SW-2103-220-SP(H) 220 g 220 mg–66 g 50–65 223.5 61.4 300/20.7 4 8
SW-2103-330-SP(H) 330 g 330 mg–99 g 50–65 280.2 61.4 250/17.2 3 6

※ Compatible with all flash chromatography systems on the market.

Double Loading Capacity of SepaFlash™ Cartridges pre-packed with high-capacity silica gel (700 m2 /g for 50 Å pore size) delivers the highest purification performance. The high-capacity 25 µm or 15 µm spherical silica has 40% higher surface area, doubling the loading capacity of lower surface area silica. Santai evaluated the performance of the SepaFlash™ columns compared to two well-known brands. Results show SepaFlash™ outperforms the competitors.

HP3
HP4


Product detail pictures:

Wholesale Price Standard Flash Column - SepaFlash™ HP Series – Santai detail pictures


Related Product Guide:

We support our purchasers with ideal premium quality products and substantial level company. Becoming the specialist manufacturer in this sector, we've acquired rich practical working experience in producing and managing for Wholesale Price Standard Flash Column - SepaFlash™ HP Series – Santai , The product will supply to all over the world, such as: Chile, America, Colombia, They're durable modeling and promoting well all over the world. Under no circumstances disappearing key functions in a brief time, it's a should for you personally of fantastic quality. Guided by the principle of Prudence, Efficiency, Union and Innovation. the business make an awesome efforts to expand its international trade, raise its enterprise. rofit and improve its export scale. We are confident that we'll have a vibrant prospect and to be distributed all over the world in the years to come.
  • The company keeps to the operation concept "scientific management, high quality and efficiency primacy, customer supreme", we have always maintained business cooperation. Work with you,we feel easy!
    5 Stars By Chris from Porto - 2018.09.19 18:37
    Company director has very rich management experience and strict attitude, sales staff are warm and cheerful, technical staff are professional and responsible,so we have no worry about product,a nice manufacturer.
    5 Stars By Mignon from Bulgaria - 2017.11.12 12:31
    Write your message here and send it to us