Mfululizo wa dhamana ya Sepaflash ™
Nguzo za Flash za Mfululizo wa Bonded zinatengenezwa na cartridge sawa na safu ya HP lakini imejaa hali ya juu, ya hali ya juu au yenye ufanisi wa juu. Bidhaa hizi za mfululizo zinaweza kutoa aina nyingi za uchawi kukidhi mahitaji ya watumiaji tofauti.
※ Inapatikana katika anuwai anuwai.
Shinikiza iliyoboreshwa ilikadiriwa hadi 400 psi.
Reusability: Mara 20 (wastani).
※ mbadala wa kiuchumi kwa HPLC ya maandalizi.
Kukidhi mahitaji anuwai ya utakaso maalum.
Ultra-pure isiyo ya kawaida C18, 40-63 µm, 60 Å
(Yaliyomo kaboni 17%, upangaji wa mwisho, eneo la uso 500 m2/g, upakiaji uwezo 0.1-2%)
Nambari ya bidhaa | Saizi ya safu | Saizi ya mfano | Vitengo/sanduku | Kiwango cha mtiririko (ml/min) | Urefu wa cartridge (mm) | Kitambulisho cha Cartridge (mm) | Max. Shinikizo (psi/bar) |
SW-5201-004-IR | 5.9 g | 5.9 mg -118 mg | 2 | 10-20 | 113.8 | 12.4 | 400/27.5 |
SW-5201-012-IR | 23 g | 23mg -0.46g | 1 | 15-30 | 134.8 | 21.4 | 400/27.5 |
SW-5201-025-IR | 38 g | 38 mg -0.76 g | 1 | 15-30 | 184 | 21.4 | 400/27.5 |
SW-5201-040-IR | 55 g | 55 mg -1.1 g | 1 | 20-40 | 184.4 | 26.7 | 400/27.5 |
SW-5201-080-IR | 122 g | 122 mg -2.5 g | 1 | 30-60 | 257.4 | 31.2 | 350/24.0 |
SW-5201-120-IR | 180 g | 180 mg -3.6 g | 1 | 40-80 | 261.5 | 38.6 | 300/20.7 |
SW-5201-220-IR | 340 g | 340 mg -6.8 g | 1 | 50-100 | 223.5 | 61.4 | 300/20.7 |
SW-5201-330-IR | 475 g | 475 mg -9.5 g | 1 | 50-100 | 280.2 | 61.4 | 250/17.2 |
※ Sambamba na mifumo yote ya chromatografia kwenye soko.
Ultra-pure isiyo ya kawaida C18, 40-63 µM, 90 Å
(Yaliyomo kaboni 15%, upangaji wa mwisho, eneo la uso 400 m2/g, upakiaji uwezo 0.1-2%)
Nambari ya bidhaa | Saizi ya safu | Saizi ya mfano | Vitengo/sanduku | Kiwango cha mtiririko (ml/min) | Urefu wa cartridge (mm) | Kitambulisho cha Cartridge (mm) | Max. Shinikizo (psi/bar) |
SW-5211-004-IR | 5.2 g | 5.2 mg -104 mg | 2 | 10-20 | 113.8 | 12.4 | 400/27.5 |
SW-5211-012-IR | 20 g | 20 mg -0.40 g | 1 | 15-30 | 134.8 | 21.4 | 400/27.5 |
SW-5211-025-IR | 33 g | 33 mg -0.66 g | 1 | 15-30 | 184 | 21.4 | 400/27.5 |
SW-5211-040-IR | 48 g | 48 mg -0.96 g | 1 | 20-40 | 184.4 | 26.7 | 400/27.5 |
SW-5211-080-IR | 105 g | 105 mg -2.1 g | 1 | 30-60 | 257.4 | 31.2 | 350/24.0 |
SW-5211-120-IR | 155 g | 155 mg -3.1 g | 1 | 40-80 | 261.5 | 38.6 | 300/20.7 |
SW-5211-220-IR | 295 g | 295 mg -5.9 g | 1 | 50-100 | 223.5 | 61.4 | 300/20.7 |
SW-5211-330-IR | 420 g | 420 mg -8.4 g | 1 | 50-100 | 280.2 | 61.4 | 250/17.2 |
※ Sambamba na mifumo yote ya chromatografia kwenye soko.
Ultra-pure spherical C18, 40-60 µm, 120 Å
.
Nambari ya bidhaa | Saizi ya safu | Saizi ya mfano | Vitengo/sanduku | Kiwango cha mtiririko (ml/min) | Urefu wa cartridge (mm) | Kitambulisho cha Cartridge (mm) | Max. Shinikizo (psi/bar) |
SW-5231-004-sp | 4.5 g | 4.5 mg -68 mg | 2 | 10-20 | 113.8 | 12.4 | 400/27.5 |
SW-5231-012-sp | 18 g | 18 mg -0.27 g | 1 | 15-30 | 134.8 | 21.4 | 400/27.5 |
SW-5231-025-sp | 28 g | 28 mg -0.42 g | 1 | 15-30 | 184 | 21.4 | 400/27.5 |
SW-5231-040-sp | 40 g | 40 mg -0.60 g | 1 | 20-40 | 184.4 | 26.7 | 400/27.5 |
SW-5231-080-sp | 90 g | 90 mg -1.35 g | 1 | 30-60 | 257.4 | 31.2 | 350/24.0 |
SW-5231-120-sp | 130 g | 130 mg -1.95 g | 1 | 40-80 | 261.5 | 38.6 | 300/20.7 |
SW-5231-220-sp | 245 g | 245 mg -3.68 g | 1 | 50-100 | 223.5 | 61.4 | 300/20.7 |
SW-5231-330-sp | 350 g | 350 mg -5.25 g | 1 | 50-100 | 280.2 | 61.4 | 250/17.2 |
※ Sambamba na mifumo yote ya chromatografia kwenye soko.
Ufanisi wa hali ya juu C18, 30-50 µm, 120 Å
(Yaliyomo kaboni 17%, upangaji wa mwisho, eneo la uso 300 m2/g, upakiaji uwezo 0.1-2%)
Nambari ya bidhaa | Saizi ya safu | Saizi ya mfano | Vitengo/sanduku | Kiwango cha mtiririko (ml/min) | Urefu wa cartridge (mm) | Kitambulisho cha Cartridge (mm) | Max. Shinikizo (psi/bar) |
SW-5232-004-sp | 4.3 g | 4.3 mg -86 mg | 2 | 5-15 | 113.8 | 12.4 | 400/27.5 |
SW-5232-012-sp | 16 g | 16 mg -0.32 g | 1 | 10-25 | 134.8 | 21.4 | 400/27.5 |
SW-5232-025-sp | 26 g | 26 mg -0.52 g | 1 | 10-25 | 184 | 21.4 | 400/27.5 |
SW-5232-040-sp | 39 g | 39 mg -0.78 g | 1 | 15-30 | 184.4 | 26.7 | 400/27.5 |
SW-5232-080-sp | 85 g | 85 mg -1.7 g | 1 | 20-50 | 257.4 | 31.2 | 350/24.0 |
SW-5232-120-sp | 125 g | 125 mg -2.5 g | 1 | 30-60 | 261.5 | 38.6 | 300/20.7 |
SW-5232-220-sp | 240 g | 240 mg -4.8 g | 1 | 40-80 | 223.5 | 61.4 | 300/20.7 |
SW-5232-330-sp | 335 g | 335 mg -6.7 g | 1 | 40-80 | 280.2 | 61.4 | 250/17.2 |
※ Sambamba na mifumo yote ya chromatografia kwenye soko.
Ultra-pure spherical C18, 40-75 µm, 100 Å
(Yaliyomo kaboni 17%, upangaji wa mwisho, eneo la uso 300 m2/g, upakiaji uwezo 0.1-1.5%)
Nambari ya bidhaa | Saizi ya safu | Saizi ya mfano | Vitengo/sanduku | Kiwango cha mtiririko (ml/min) | Urefu wa cartridge (mm) | Kitambulisho cha Cartridge (mm) | Max. Shinikizo (psi/bar) |
SW-5221-004-SP | 4.6 g | 4.6 mg -69 mg | 2 | 10-20 | 113.8 | 12.4 | 400/27.5 |
SW-5221-012-sp | 18 g | 18 mg -0.27 g | 1 | 15-30 | 134.8 | 21.4 | 400/27.5 |
SW-5221-025-sp | 30 g | 30 mg -0.45 g | 1 | 15-30 | 184 | 21.4 | 400/27.5 |
SW-5221-040-sp | 43 g | 43 mg -0.65 g | 1 | 20-40 | 184.4 | 26.7 | 400/27.5 |
SW-5221-080-SP | 95 g | 95 mg -1.43 g | 1 | 30-60 | 257.4 | 31.2 | 350/24.0 |
SW-5221-120-sp | 142 g | 142 mg -2.13 g | 1 | 40-80 | 261.5 | 38.6 | 300/20.7 |
SW-5221-220-sp | 265 g | 265 mg -3.98 g | 1 | 50-100 | 223.5 | 61.4 | 300/20.7 |
SW-5221-330-sp | 385 g | 385 mg -5.78 g | 1 | 50-100 | 280.2 | 61.4 | 250/17.2 |
※ Sambamba na mifumo yote ya chromatografia kwenye soko.
Ufanisi wa hali ya juu C18, 20-45 µm, 100 Å
(Yaliyomo kaboni 17%, upangaji wa mwisho, eneo la uso 320 m2/g, upakiaji uwezo 0.1-2%)
Nambari ya bidhaa | Saizi ya safu | Saizi ya mfano | Vitengo/sanduku | Kiwango cha mtiririko (ml/min) | Urefu wa cartridge (mm) | Kitambulisho cha Cartridge (mm) | Max. Shinikizo (psi/bar) |
SW-5222-004-sp | 5.4 g | 5.4 mg -108 mg | 2 | 5-15 | 113.8 | 12.4 | 400/27.5 |
SW-5222-012-sp | 20 g | 20 mg -0.40 g | 1 | 10-25 | 134.8 | 21.4 | 400/27.5 |
SW-5222-025-sp | 33 g | 33 mg -0.66 g | 1 | 10-25 | 184 | 21.4 | 400/27.5 |
SW-5222-040-SP | 48 g | 48 mg -0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400/27.5 |
SW-5222-080-SP | 105 g | 105 mg -2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350/24.0 |
SW-5222-120-sp | 155 g | 155 mg -3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300/20.7 |
SW-5222-220-sp | 300 g | 300 mg -6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300/20.7 |
SW-5222-330-sp | 420 g | 420 mg -8.4 g | 1 | 40-80 | 280.2 | 61.4 | 250/17.2 |
※ Sambamba na mifumo yote ya chromatografia kwenye soko.
Ufanisi wa hali ya juu C18 (aq), 20-45 µm, 100 Å (bidhaa mpya)
(Yaliyomo kaboni 10%, upangaji wa mwisho, eneo la uso 320 m2/g, upakiaji uwezo 0.1-2%)
Nambari ya bidhaa | Saizi ya safu | Saizi ya mfano | Vitengo/sanduku | Kiwango cha mtiririko (ml/min) | Urefu wa cartridge (mm) | Kitambulisho cha Cartridge (mm) | Max. Shinikizo (psi/bar) |
SW-5222-004-SP (aq) | 5.4 g | 5.4 mg -108 mg | 2 | 5-15 | 113.8 | 12.4 | 400/27.5 |
SW-5222-012-SP (aq) | 20 g | 20 mg -0.40 g | 1 | 10-25 | 134.8 | 21.4 | 400/27.5 |
SW-5222-025-SP (aq) | 33 g | 33 mg -0.66 g | 1 | 10-25 | 184 | 21.4 | 400/27.5 |
SW-5222-040-SP (aq) | 48 g | 48 mg -0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400/27.5 |
SW-5222-080-SP (aq) | 105 g | 105 mg -2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350/24.0 |
SW-5222-120-SP (aq) | 155 g | 155 mg -3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300/20.7 |
SW-5222-220-SP (aq) | 300 g | 300 mg -6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300/20.7 |
SW-5222-330-SP (aq) | 420 g | 420 mg -8.4 g | 1 | 40-80 | 280.2 | 61.4 | 250/17.2 |
※ Sambamba na mifumo yote ya chromatografia kwenye soko.
Ufanisi wa hali ya juu C18, 15 µM, 100 Å
(Yaliyomo kaboni 17%, upangaji wa mwisho, eneo la uso 320 m2/g, upakiaji uwezo 0.1-2%)
Nambari ya bidhaa | Saizi ya safu | Saizi ya mfano | Vitengo/sanduku | Kiwango cha mtiririko (ml/min) | Urefu wa cartridge (mm) | Kitambulisho cha Cartridge (mm) | Max. Shinikizo (psi/bar) |
SW-5223-004-sp | 5.4 g | 5.4 mg -108 mg | 2 | 5-15 | 113.8 | 12.4 | 400/27.5 |
SW-5223-012-sp | 20 g | 20 mg -0.40 g | 1 | 10-25 | 134.8 | 21.4 | 400/27.5 |
SW-5223-025-sp | 33 g | 33 mg -0.66 g | 1 | 10-25 | 184 | 21.4 | 400/27.5 |
SW-5223-040-sp | 48 g | 48 mg -0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400/27.5 |
SW-5223-080-SP | 105 g | 105 mg -2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350/24.0 |
SW-5223-120-sp | 155 g | 155 mg -3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300/20.7 |
SW-5223-220-sp | 290 g | 290 mg -5.8 g | 1 | 40-80 | 223.5 | 61.4 | 300/20.7 |
SW-5223-330-sp | 410 g | 410 mg -8.2 g | 1 | 40-80 | 280.2 | 61.4 | 250/17.2 |
※ Sambamba na mifumo yote ya chromatografia kwenye soko.
Ufanisi wa hali ya juu CN, 20-45 µm, 100 Å
(Yaliyomo kaboni 5.5%, upangaji wa mwisho, eneo la uso 320 m2/g, upakiaji uwezo 0.1-2%)
Nambari ya bidhaa | Saizi ya safu | Saizi ya mfano | Vitengo/sanduku | Kiwango cha mtiririko (ml/min) | Urefu wa cartridge (mm) | Kitambulisho cha Cartridge (mm) | Max. Shinikizo (psi/bar) |
SW-5322-004-sp | 5.4 g | 5.4 mg -108 mg | 2 | 5-15 | 113.8 | 12.4 | 400/27.5 |
SW-5322-012-sp | 20 g | 20 mg -0.40 g | 1 | 10-25 | 134.8 | 21.4 | 400/27.5 |
SW-5322-025-sp | 33 g | 33 mg -0.66 g | 1 | 10-25 | 184 | 21.4 | 400/27.5 |
SW-5322-040-sp | 48 g | 48 mg -0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400/27.5 |
SW-5322-080-sp | 105 g | 105 mg -2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350/24.0 |
SW-5322-120-sp | 155 g | 155 mg -3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300/20.7 |
SW-5322-220-sp | 300 g | 300 mg -6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300/20.7 |
SW-5322-330-sp | 420 g | 420 mg -8.4 g | 1 | 40-80 | 280.2 | 61.4 | 250/17.2 |
※ Sambamba na mifumo yote ya chromatografia kwenye soko.
Ufanisi wa hali ya juu C4, 20-45 µm, 100 Å
(Yaliyomo kaboni 5.8%, upangaji wa mwisho, eneo la uso 320 m2/g, upakiaji uwezo 0.1-2%)
Nambari ya bidhaa | Saizi ya safu | Saizi ya mfano | Vitengo/sanduku | Kiwango cha mtiririko (ml/min) | Urefu wa cartridge (mm) | Kitambulisho cha Cartridge (mm) | Max. Shinikizo (psi/bar) |
SW-5422-004-sp | 5.4 g | 5.4 mg -108 mg | 2 | 5-15 | 113.8 | 12.4 | 400/27.5 |
SW-5422-012-sp | 20 g | 20 mg -0.40 g | 1 | 10-25 | 134.8 | 21.4 | 400/27.5 |
SW-5422-025-sp | 33 g | 33 mg -0.66 g | 1 | 10-25 | 184 | 21.4 | 400/27.5 |
SW-5422-040-sp | 48 g | 48 mg -0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400/27.5 |
SW-5422-080-sp | 105 g | 105 mg -2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350/24.0 |
SW-5422-120-sp | 155 g | 155 mg -3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300/20.7 |
SW-5422-220-sp | 300 g | 300 mg -6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300/20.7 |
SW-5422-330-sp | 420 g | 420 mg -8.4 g | 1 | 40-80 | 280.2 | 61.4 | 250/17.2 |
※ Sambamba na mifumo yote ya chromatografia kwenye soko.
Ufanisi wa hali ya juu, 20-45 µm, 100 Å (bidhaa mpya)
(Yaliyomo ya kaboni 8%, upangaji wa mwisho, eneo la uso 320 m2/g, upakiaji uwezo 0.1-2%)
Nambari ya bidhaa | Saizi ya safu | Saizi ya mfano | Vitengo/sanduku | Kiwango cha mtiririko (ml/min) | Urefu wa cartridge (mm) | Kitambulisho cha Cartridge (mm) | Max. Shinikizo (psi/bar) |
SW-5622-004-sp | 5.4 g | 5.4 mg -108 mg | 2 | 5-15 | 113.8 | 12.4 | 400/27.5 |
SW-5622-012-sp | 20 g | 20 mg -0.40 g | 1 | 10-25 | 134.8 | 21.4 | 400/27.5 |
SW-5622-025-sp | 33 g | 33 mg -0.66 g | 1 | 10-25 | 184 | 21.4 | 400/27.5 |
SW-5622-040-sp | 48 g | 48 mg -0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400/27.5 |
SW-5622-080-SP | 105 g | 105 mg -2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350/24.0 |
SW-5622-120-sp | 155 g | 155 mg -3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300/20.7 |
SW-5622-220-sp | 300 g | 300 mg -6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300/20.7 |
SW-5622-330-sp | 420 g | 420 mg -8.4 g | 1 | 40-80 | 280.2 | 61.4 | 250/17.2 |
※ Sambamba na mifumo yote ya chromatografia kwenye soko.
Ufanisi wa hali ya juu C8, 20-45 µm, 100 Å
(Yaliyomo kaboni 7%, upangaji wa mwisho, eneo la uso 320 m2/g, upakiaji uwezo 0.1-2%)
Nambari ya bidhaa | Saizi ya safu | Saizi ya mfano | Vitengo/sanduku | Kiwango cha mtiririko (ml/min) | Urefu wa cartridge (mm) | Kitambulisho cha Cartridge (mm) | Max. Shinikizo (psi/bar) |
SW-5822-004-sp | 5.4 g | 5.4 mg -108 mg | 2 | 5-15 | 113.8 | 12.4 | 400/27.5 |
SW-5822-012-sp | 20 g | 20 mg -0.40 g | 1 | 10-25 | 134.8 | 21.4 | 400/27.5 |
SW-5822-025-sp | 33 g | 33 mg -0.66 g | 1 | 10-25 | 184 | 21.4 | 400/27.5 |
SW-5822-040-sp | 48 g | 48 mg -0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400/27.5 |
SW-5822-080-sp | 105 g | 105 mg -2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350/24.0 |
SW-5822-120-sp | 155 g | 155 mg -3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300/20.7 |
SW-5822-220-sp | 300 g | 300 mg -6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300/20.7 |
SW-5822-330-sp | 420 g | 420 mg -8.4 g | 1 | 40-80 | 280.2 | 61.4 | 250/17.2 |
※ Sambamba na mifumo yote ya chromatografia kwenye soko.
Ufanisi wa hali ya juu C8 (aq), 20-45 µm, 100 Å (bidhaa mpya)
(Yaliyomo kaboni 7%, upangaji wa mwisho, eneo la uso 320 m2/g, upakiaji uwezo 0.1-2%)
Nambari ya bidhaa | Saizi ya safu | Saizi ya mfano | Vitengo/sanduku | Kiwango cha mtiririko (ml/min) | Urefu wa cartridge (mm) | Kitambulisho cha Cartridge (mm) | Max. Shinikizo (psi/bar) |
SW-5822-004-SP (aq) | 5.4 g | 5.4 mg -108 mg | 2 | 5-15 | 113.8 | 12.4 | 400/27.5 |
SW-5822-012-SP (aq) | 20 g | 20 mg -0.40 g | 1 | 10-25 | 134.8 | 21.4 | 400/27.5 |
SW-5822-025-SP (aq) | 33 g | 33 mg -0.66 g | 1 | 10-25 | 184 | 21.4 | 400/27.5 |
SW-5822-040-SP (aq) | 48 g | 48 mg -0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400/27.5 |
SW-5822-080-SP (aq) | 105 g | 105 mg -2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350/24.0 |
SW-5822-120-SP (aq) | 155 g | 155 mg -3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300/20.7 |
SW-5822-220-SP (aq) | 300 g | 300 mg -6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300/20.7 |
SW-5822-330-SP (aq) | 420 g | 420 mg -8.4 g | 1 | 40-80 | 280.2 | 61.4 | 250/17.2 |
※ Sambamba na mifumo yote ya chromatografia kwenye soko.
Ufanisi wa kiwango cha juu cha spherical diol, 20-45 µm, 100 Å
(Yaliyomo ya kaboni 5%, upangaji wa mwisho, eneo la uso 320 m2/g, upakiaji uwezo 0.1-2%)
Nambari ya bidhaa | Saizi ya safu | Saizi ya mfano | Vitengo/sanduku | Kiwango cha mtiririko (ml/min) | Urefu wa cartridge (mm) | Kitambulisho cha Cartridge (mm) | Max. Shinikizo (psi/bar) |
SW-5922-004-SP | 5.4 g | 5.4 mg -108 mg | 2 | 5-15 | 113.8 | 12.4 | 400/27.5 |
SW-5922-012-sp | 20 g | 20 mg -0.40 g | 1 | 10-25 | 134.8 | 21.4 | 400/27.5 |
SW-5922-025-sp | 33 g | 33 mg -0.66 g | 1 | 10-25 | 184 | 21.4 | 400/27.5 |
SW-5922-040-SP | 48 g | 48 mg -0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400/27.5 |
SW-5922-080-SP | 105 g | 105 mg -2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350/24.0 |
SW-5922-120-sp | 155 g | 155 mg -3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300/20.7 |
SW-5922-220-sp | 300 g | 300 mg -6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300/20.7 |
SW-5922-330-SP | 420 g | 420 mg -8.4 g | 1 | 40-80 | 280.2 | 61.4 | 250/17.2 |
※ Sambamba na mifumo yote ya chromatografia kwenye soko.
Ufanisi wa hali ya juu wa spherical, 20-45 µM, 100 Å
(Yaliyomo kaboni 10%, upangaji wa mwisho, eneo la uso 320 m2/g, upakiaji uwezo 0.1-2%)
Nambari ya bidhaa | Saizi ya safu | Saizi ya mfano | Vitengo/sanduku | Kiwango cha mtiririko (ml/min) | Urefu wa cartridge (mm) | Kitambulisho cha Cartridge (mm) | Max. Shinikizo (psi/bar) |
SW-5B22-004-SP | 5.4 g | 5.4 mg -108 mg | 2 | 5-15 | 113.8 | 12.4 | 400/27.5 |
SW-5B22-012-SP | 20 g | 20 mg -0.40 g | 1 | 10-25 | 134.8 | 21.4 | 400/27.5 |
SW-5B22-025-SP | 33 g | 33 mg -0.66 g | 1 | 10-25 | 184 | 21.4 | 400/27.5 |
SW-5B22-040-SP | 48 g | 48 mg -0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400/27.5 |
SW-5B22-080-SP | 105 g | 105 mg -2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350/24.0 |
SW-5B22-120-SP | 155 g | 155 mg -3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300/20.7 |
SW-5B22-220-SP | 300 g | 300 mg -6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300/20.7 |
SW-5B22-330-SP | 420 g | 420 mg -8.4 g | 1 | 40-80 | 280.2 | 61.4 | 250/17.2 |
※ Sambamba na mifumo yote ya chromatografia kwenye soko.
Ufanisi wa hali ya juu ya spherical-hexyl, 20-45 µM, 100 Å
(Yaliyomo kaboni 10%, upangaji wa mwisho, eneo la uso 320 m2/g, upakiaji uwezo 0.1-2%)
Nambari ya bidhaa | Saizi ya safu | Saizi ya mfano | Vitengo/sanduku | Kiwango cha mtiririko (ml/min) | Urefu wa cartridge (mm) | Kitambulisho cha Cartridge (mm) | Max. Shinikizo (psi/bar) |
SW-5C22-004-SP | 5.4 g | 5.4 mg -108 mg | 2 | 5-15 | 113.8 | 12.4 | 400/27.5 |
SW-5C22-012-SP | 20 g | 20 mg -0.40 g | 1 | 10-25 | 134.8 | 21.4 | 400/27.5 |
SW-5C22-025-SP | 33 g | 33 mg -0.66 g | 1 | 10-25 | 184 | 21.4 | 400/27.5 |
SW-5C22-040-SP | 48 g | 48 mg -0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400/27.5 |
SW-5C22-080-SP | 105 g | 105 mg -2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350/24.0 |
SW-5C22-120-SP | 155 g | 155 mg -3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300/20.7 |
SW-5C22-220-SP | 300 g | 300 mg -6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300/20.7 |
SW-5C22-330-SP | 420 g | 420 mg -8.4 g | 1 | 40-80 | 280.2 | 61.4 | 250/17.2 |
※ Sambamba na mifumo yote ya chromatografia kwenye soko.
Ultra-pure isiyo ya kawaida NH2, 40-63 µm, 60 Å
(amino content 1.3 mmol/g, end-capping, surface area 500 m2/g, upakiaji uwezo 0.1-2%)
Nambari ya bidhaa | Saizi ya safu | Saizi ya mfano | Vitengo/sanduku | Kiwango cha mtiririko (ml/min) | Urefu wa cartridge (mm) | Kitambulisho cha Cartridge (mm) | Max. Shinikizo (psi/bar) |
SW-5501-004-IR | 5.9 g | 5.9 mg -118 mg | 2 | 10-20 | 113.8 | 12.4 | 400/27.5 |
SW-5501-012-IR | 23 g | 23 mg -0.46 g | 1 | 15-30 | 134.8 | 21.4 | 400/27.5 |
SW-5501-025-IR | 38 g | 38 mg -0.76 g | 1 | 15-30 | 184 | 21.4 | 400/27.5 |
SW-5501-040-IR | 55 g | 55 mg -1.1 g | 1 | 20-40 | 184.4 | 26.7 | 400/27.5 |
SW-5501-080-IR | 122 g | 122 mg -2.5 g | 1 | 30-60 | 257.4 | 31.2 | 350/24.0 |
SW-5501-120-IR | 180 g | 180 mg -3.6 g | 1 | 40-80 | 261.5 | 38.6 | 300/20.7 |
SW-5501-220-IR | 340 g | 340 mg -6.8 g | 1 | 50-100 | 223.5 | 61.4 | 300/20.7 |
SW-5501-330-IR | 475 g | 475 mg -9.5 g | 1 | 50-100 | 280.2 | 61.4 | 250/17.2 |
※ Sambamba na mifumo yote ya chromatografia kwenye soko.
Ultra-pure kawaida sax, 40-63 µm, 60 Å
(Yaliyomo kaboni 8%, eneo la uso 500 m2/g, uwezo wa kubadilishana wa ion ≤ 0.26 mEq/g)
Nambari ya bidhaa | Saizi ya safu | Saizi ya mfano | Vitengo/sanduku | Kiwango cha mtiririko (ml/min) | Urefu wa cartridge (mm) | Kitambulisho cha Cartridge (mm) | Max. Shinikizo (psi/bar) |
SW-5001-004-IR | 5.9 g | ≤ 1.53 meq | 2 | 10-20 | 113.8 | 12.4 | 400/27.5 |
SW-5001-012-IR | 23 g | ≤ 5.98 meq | 1 | 15-30 | 134.8 | 21.4 | 400/27.5 |
SW-5001-025-IR | 38 g | ≤ 9.88 meq | 1 | 15-30 | 184 | 21.4 | 400/27.5 |
SW-5001-040-IR | 55 g | ≤ 14.30 meq | 1 | 20-40 | 184.4 | 26.7 | 400/27.5 |
SW-5001-080-IR | 122 g | ≤ 31.72 meq | 1 | 30-60 | 257.4 | 31.2 | 350/24.0 |
SW-5001-120-IR | 180 g | ≤ 46.80 meq | 1 | 40-80 | 261.5 | 38.6 | 300/20.7 |
SW-5001-220-IR | 340 g | ≤ 88.40 meq | 1 | 50-100 | 223.5 | 61.4 | 300/20.7 |
SW-5001-330-IR | 475 g | ≤ 123.50 meq | 1 | 50-100 | 280.2 | 61.4 | 250/17.2 |
※ Sambamba na mifumo yote ya chromatografia kwenye soko.
Ultra-pure isiyo ya kawaida SCX, 40-63 µm, 60 Å
(Yaliyomo kaboni 10%, eneo la uso 500 m2/g, uwezo wa kubadilishana wa ion ≤ 0.34 mEq/g)
Nambari ya bidhaa | Saizi ya safu | Saizi ya mfano | Vitengo/sanduku | Kiwango cha mtiririko (ml/min) | Urefu wa cartridge (mm) | Kitambulisho cha Cartridge (mm) | Max. Shinikizo (psi/bar) |
SW-5701-004-IR | 5.9 g | ≤ 2.01 meq | 2 | 10-20 | 113.8 | 12.4 | 400/27.5 |
SW-5701-012-IR | 23 g | ≤ 7.82 meq | 1 | 15-30 | 134.8 | 21.4 | 400/27.5 |
SW-5701-025-IR | 38 g | ≤ 12.92 meq | 1 | 15-30 | 184 | 21.4 | 400/27.5 |
SW-5701-040-IR | 55 g | ≤ 18.70 meq | 1 | 20-40 | 184.4 | 26.7 | 400/27.5 |
SW-5701-080-IR | 122 g | ≤ 41.48 meq | 1 | 30-60 | 257.4 | 31.2 | 350/24.0 |
SW-5701-120-IR | 180 g | ≤ 61.20 meq | 1 | 40-80 | 261.5 | 38.6 | 300/20.7 |
SW-5701-220-IR | 340 g | ≤ 115.60 meq | 1 | 50-100 | 223.5 | 61.4 | 300/20.7 |
SW-5701-330-IR | 475 g | ≤ 161.50 meq | 1 | 50-100 | 280.2 | 61.4 | 250/17.2 |
※ Sambamba na mifumo yote ya chromatografia kwenye soko.
- Katalogi ya safu ya Sepaflash En
- AN001-Utakaso wa misombo ya hydrophilic na Cartridges za Sepaflash ™ HILIC
- AN003-Matumizi ya Cartridges za Sepaflash ™ HILIC katika Utakaso wa Syntetisk
- AN004-Chaguo la awamu ya rununu katika chromatografia ya awamu iliyobadilishwa
- AN008-Uchunguzi wa Njia ya Maandalizi ya Kuongeza Up na safu wima za Awamu ya Sepaflash ™
- AN010-Matumizi ya Cartridges za Awamu ya Sepaflash ™ kwa sampuli za polar na za chini sana
- AN014_Uboreshaji wa azimio kwa kuweka safu na matumizi yake
- AN015_Hydrophobic awamu ya kuanguka, AQ ilibadilisha safu wima za chromatografia
- AN016_The ya SepaFlash ™ Nguvu za Kubadilishana za chromatografia katika Utakaso wa Misombo ya Alkaline
- AN017-Utakaso wa dondoo ya ushuru na mashine ya Sepabean ™
- AN018_The Matumizi ya nguzo za C18AQ katika utakaso wa peptidi kali za polar
- AN019_Usafishaji wa uchafu wa polar sana katika dawa za kukinga na nguzo za C18AQ
- AN020-Matumizi ya safu ya chromatografia ya Sepaflash ™ katika utakaso wa misombo ya asidi
- AN024_The ya chromatografia ya orthogonal kwa utakaso wa waingiliano wa dawa za synthetic
- AN026_Tumia ya Sepaflash ™ Hilic Arg Cartridge kwa utakaso wa kiwanja chenye nguvu cha polar thiazide
- AN027_SEPAFLASH ™ Hilic Arg Cartridge na matumizi yake katika utakaso wa oligosaccharides
- Mwongozo wa AN028_USER kwa kutumia, kusafisha na kuhifadhi kwa safu ya safu ya Flash ya Sepaflash ™
- AN029_SEPAFLASH ™ C18AQ Cartridge na matumizi yake katika utakaso wa derivatives ya glutamine
- AN033_SEPAFLASH ™ Hilic Arg Cartridge na matumizi yake katika utakaso wa derivatives ya amino asidi
- AN036_SEPAFLASH ™ C18AQ Cartridge na matumizi yake katika sampuli ya kupunguka
- Utakaso wa uso wa AN-SS-003
- Mgawanyo wa AN-SS-006 wa CBD na THC na safu wima za SPERASH ™ C18