page_banner

SepaFlash™ Bonded Series

SepaFlash™ Bonded Series

Short Description:

Bonded series flash columns are manufactured with the same cartridges as the HP series but are packed with UltraPure, high-quality, high-efficiency bonded silica.

※ Offer a wide variety of sorbents to better satisfy requirements of different users.


Product Detail

Application

Video

catalogue

Product Introduction

Bonded series flash columns are manufactured with the same cartridges as the HP series but are packed with UltraPure, high-quality or high-efficiency bonded silica. This series products could offer a wide variety of sorbents to better satisfy the requirements for different users.

※ Available in a wide variety of specifications.
※ Improved pressure rated up to 400 psi.
※ Reusability: 20 times (average).
※ Economical substitute for preparative HPLC.
※ Meet a variety of needs for specific purifications.

Ordering Information (15 kinds of bonded silica available)

Ultra-pure irregular C18, 40-63 µm, 60 Å
 (carbon content 17%, end-capping, surface area 500 m2/g, loading capacity 0.1–2%)

Item Number Column Size Sample Size Units/Box Flow Rate (mL/min) Cartridge Length (mm) Cartridge ID (mm) Max. Pressure (psi/bar)
SW-5201-004-IR 5.9 g 5.9 mg–118 mg 2 10–20 113.8 12.4 400/27.5
SW-5201-012-IR 23 g 23mg–0.46g 1 15–30 134.8 21.4 400/27.5
SW-5201-025-IR 38 g 38 mg–0.76 g 1 15–30 184 21.4 400/27.5
SW-5201-040-IR 55 g 55 mg–1.1 g 1 20–40 184.4 26.7 400/27.5
SW-5201-080-IR 122 g 122 mg–2.5 g 1 30–60 257.4 31.2 350/24.0
SW-5201-120-IR 180 g 180 mg–3.6 g 1 40–80 261.5 38.6 300/20.7
SW-5201-220-IR 340 g 340 mg–6.8 g 1 50–100 223.5 61.4 300/20.7
SW-5201-330-IR 475 g 475 mg–9.5 g 1 50–100 280.2 61.4 250/17.2

※ Compatible with all flash chromatography systems on the market.

Ultra-pure irregular C18, 40-63 µm, 90 Å
(carbon content 15%, end-capping, surface area 400 m2/g, loading capacity 0.1–2%)

Item Number Column Size Sample Size Units/Box Flow Rate (mL/min) Cartridge Length (mm) Cartridge ID (mm) Max. Pressure (psi/bar)
SW-5211-004-IR 5.2 g 5.2 mg–104 mg 2 10–20 113.8 12.4 400/27.5
SW-5211-012-IR 20 g 20 mg–0.40 g 1 15–30 134.8 21.4 400/27.5
SW-5211-025-IR 33 g 33 mg–0.66 g 1 15–30 184 21.4 400/27.5
SW-5211-040-IR 48 g 48 mg–0.96 g 1 20–40 184.4 26.7 400/27.5
SW-5211-080-IR 105 g 105 mg–2.1 g 1 30–60 257.4 31.2 350/24.0
SW-5211-120-IR 155 g 155 mg–3.1 g 1 40–80 261.5 38.6 300/20.7
SW-5211-220-IR 295 g 295 mg–5.9 g 1 50–100 223.5 61.4 300/20.7
SW-5211-330-IR 420 g 420 mg–8.4 g 1 50–100 280.2 61.4 250/17.2

※ Compatible with all flash chromatography systems on the market.

Ultra-pure spherical C18, 40-60 µm, 120 Å
(carbon content 17%, end-capping, surface area 300 m2/g, loading capacity 0.1–1.5%)

Item Number Column Size Sample Size Units/Box Flow Rate (mL/min) Cartridge Length (mm) Cartridge ID (mm) Max. Pressure (psi/bar)
SW-5231-004-SP 4.5 g 4.5 mg–68 mg 2 10–20 113.8 12.4 400/27.5
SW-5231-012-SP 18 g 18 mg–0.27 g 1 15–30 134.8 21.4 400/27.5
SW-5231-025-SP 28 g 28 mg–0.42 g 1 15–30 184 21.4 400/27.5
SW-5231-040-SP 40 g 40 mg–0.60 g 1 20–40 184.4 26.7 400/27.5
SW-5231-080-SP 90 g 90 mg–1.35 g 1 30–60 257.4 31.2 350/24.0
SW-5231-120-SP 130 g 130 mg–1.95 g 1 40–80 261.5 38.6 300/20.7
SW-5231-220-SP 245 g 245 mg–3.68 g 1 50–100 223.5 61.4 300/20.7
SW-5231-330-SP 350 g 350 mg–5.25 g 1 50–100 280.2 61.4 250/17.2

※ Compatible with all flash chromatography systems on the market.

High-efficiency spherical C18, 30-50 µm, 120 Å
 (carbon content 17%, end-capping, surface area 300 m2/g, loading capacity 0.1–2%)

Item Number Column Size Sample Size Units/Box Flow Rate (mL/min) Cartridge Length (mm) Cartridge ID (mm) Max. Pressure (psi/bar)
SW-5232-004-SP 4.3 g 4.3 mg–86 mg 2 5–15 113.8 12.4 400/27.5
SW-5232-012-SP 16 g 16 mg–0.32 g 1 10–25 134.8 21.4 400/27.5
SW-5232-025-SP 26 g 26 mg–0.52 g 1 10–25 184 21.4 400/27.5
SW-5232-040-SP 39 g 39 mg–0.78 g 1 15–30 184.4 26.7 400/27.5
SW-5232-080-SP 85 g 85 mg–1.7 g 1 20–50 257.4 31.2 350/24.0
SW-5232-120-SP 125 g 125 mg–2.5 g 1 30–60 261.5 38.6 300/20.7
SW-5232-220-SP 240 g 240 mg–4.8 g 1 40–80 223.5 61.4 300/20.7
SW-5232-330-SP 335 g 335 mg–6.7 g 1 40–80 280.2 61.4 250/17.2

※ Compatible with all flash chromatography systems on the market.

Ultra-pure spherical C18, 40-75 µm, 100 Å
 (carbon content 17%, end-capping, surface area 300 m2/g, loading capacity 0.1–1.5%)

Item Number Column Size Sample Size Units/Box Flow Rate (mL/min) Cartridge Length (mm) Cartridge ID (mm) Max. Pressure (psi/bar)
SW-5221-004-SP 4.6 g 4.6 mg–69 mg 2 10–20 113.8 12.4 400/27.5
SW-5221-012-SP 18 g 18 mg–0.27 g 1 15–30 134.8 21.4 400/27.5
SW-5221-025-SP 30 g 30 mg–0.45 g 1 15–30 184 21.4 400/27.5
SW-5221-040-SP 43 g 43 mg–0.65 g 1 20–40 184.4 26.7 400/27.5
SW-5221-080-SP 95 g 95 mg–1.43 g 1 30–60 257.4 31.2 350/24.0
SW-5221-120-SP 142 g 142 mg–2.13 g 1 40–80 261.5 38.6 300/20.7
SW-5221-220-SP 265 g 265 mg–3.98 g 1 50–100 223.5 61.4 300/20.7
SW-5221-330-SP 385 g 385 mg–5.78 g 1 50–100 280.2 61.4 250/17.2

※ Compatible with all flash chromatography systems on the market.

High-efficiency spherical C18, 20-45 µm, 100 Å
 (carbon content 17%, end-capping, surface area 320 m2/g, loading capacity 0.1–2%)

Item Number Column Size Sample Size Units/Box Flow Rate (mL/min) Cartridge Length (mm) Cartridge ID (mm) Max. Pressure (psi/bar)
SW-5222-004-SP 5.4 g 5.4 mg–108 mg 2 5–15 113.8 12.4 400/27.5
SW-5222-012-SP 20 g 20 mg–0.40 g 1 10–25 134.8 21.4 400/27.5
SW-5222-025-SP 33 g 33 mg–0.66 g 1 10–25 184 21.4 400/27.5
SW-5222-040-SP 48 g 48 mg–0.96 g 1 15–30 184.4 26.7 400/27.5
SW-5222-080-SP 105 g 105 mg–2.1 g 1 20–50 257.4 31.2 350/24.0
SW-5222-120-SP 155 g 155 mg–3.1 g 1 30–60 261.5 38.6 300/20.7
SW-5222-220-SP 300 g 300 mg–6.0 g 1 40–80 223.5 61.4 300/20.7
SW-5222-330-SP 420 g 420 mg–8.4 g 1 40–80 280.2 61.4 250/17.2

※ Compatible with all flash chromatography systems on the market.

High-efficiency spherical C18(AQ), 20-45 µm, 100 Å (NEW Product)
 (carbon content 10%, end-capping, surface area 320 m2/g, loading capacity 0.1–2%)

Item Number Column Size Sample Size Units/Box Flow Rate (mL/min) Cartridge Length (mm) Cartridge ID (mm) Max. Pressure (psi/bar)
SW-5222-004-SP(AQ) 5.4 g 5.4 mg–108 mg 2 5–15 113.8 12.4 400/27.5
SW-5222-012-SP(AQ) 20 g 20 mg–0.40 g 1 10–25 134.8 21.4 400/27.5
SW-5222-025-SP(AQ) 33 g 33 mg–0.66 g 1 10–25 184 21.4 400/27.5
SW-5222-040-SP(AQ) 48 g 48 mg–0.96 g 1 15–30 184.4 26.7 400/27.5
SW-5222-080-SP(AQ) 105 g 105 mg–2.1 g 1 20–50 257.4 31.2 350/24.0
SW-5222-120-SP(AQ) 155 g 155 mg–3.1 g 1 30–60 261.5 38.6 300/20.7
SW-5222-220-SP(AQ) 300 g 300 mg–6.0 g 1 40–80 223.5 61.4 300/20.7
SW-5222-330-SP(AQ) 420 g 420 mg–8.4 g 1 40–80 280.2 61.4 250/17.2

※ Compatible with all flash chromatography systems on the market.

High-efficiency spherical C18, 15 µm, 100 Å
 (carbon content 17%, end-capping, surface area 320 m2/g, loading capacity 0.1–2%)

Item Number Column Size Sample Size Units/Box Flow Rate (mL/min) Cartridge Length (mm) Cartridge ID (mm) Max. Pressure (psi/bar)
SW-5223-004-SP 5.4 g 5.4 mg–108 mg 2 5–15 113.8 12.4 400/27.5
SW-5223-012-SP 20 g 20 mg–0.40 g 1 10–25 134.8 21.4 400/27.5
SW-5223-025-SP 33 g 33 mg–0.66 g 1 10–25 184 21.4 400/27.5
SW-5223-040-SP 48 g 48 mg–0.96 g 1 15–30 184.4 26.7 400/27.5
SW-5223-080-SP 105 g 105 mg–2.1 g 1 20–50 257.4 31.2 350/24.0
SW-5223-120-SP 155 g 155 mg–3.1 g 1 30–60 261.5 38.6 300/20.7
SW-5223-220-SP 290 g 290 mg–5.8 g 1 40–80 223.5 61.4 300/20.7
SW-5223-330-SP 410 g 410 mg–8.2 g 1 40–80 280.2 61.4 250/17.2

※ Compatible with all flash chromatography systems on the market.

High-efficiency spherical CN, 20-45 µm, 100 Å
 (carbon content 5.5%, end-capping, surface area 320 m2/g, loading capacity 0.1–2%)

Item Number Column Size Sample Size Units/Box Flow Rate (mL/min) Cartridge Length (mm) Cartridge ID (mm) Max. Pressure (psi/bar)
SW-5322-004-SP 5.4 g 5.4 mg–108 mg 2 5–15 113.8 12.4 400/27.5
SW-5322-012-SP 20 g 20 mg–0.40 g 1 10–25 134.8 21.4 400/27.5
SW-5322-025-SP 33 g 33 mg–0.66 g 1 10–25 184 21.4 400/27.5
SW-5322-040-SP 48 g 48 mg–0.96 g 1 15–30 184.4 26.7 400/27.5
SW-5322-080-SP 105 g 105 mg–2.1 g 1 20–50 257.4 31.2 350/24.0
SW-5322-120-SP 155 g 155 mg–3.1 g 1 30–60 261.5 38.6 300/20.7
SW-5322-220-SP 300 g 300 mg–6.0 g 1 40–80 223.5 61.4 300/20.7
SW-5322-330-SP 420 g 420 mg–8.4 g 1 40–80 280.2 61.4 250/17.2

※ Compatible with all flash chromatography systems on the market.

High-efficiency spherical C4, 20-45 µm, 100 Å
 (carbon content 5.8%, end-capping, surface area 320 m2/g, loading capacity 0.1–2%)

Item Number Column Size Sample Size Units/Box Flow Rate (mL/min) Cartridge Length (mm) Cartridge ID (mm) Max. Pressure (psi/bar)
SW-5422-004-SP 5.4 g 5.4 mg–108 mg 2 5–15 113.8 12.4 400/27.5
SW-5422-012-SP 20 g 20 mg–0.40 g 1 10–25 134.8 21.4 400/27.5
SW-5422-025-SP 33 g 33 mg–0.66 g 1 10–25 184 21.4 400/27.5
SW-5422-040-SP 48 g 48 mg–0.96 g 1 15–30 184.4 26.7 400/27.5
SW-5422-080-SP 105 g 105 mg–2.1 g 1 20–50 257.4 31.2 350/24.0
SW-5422-120-SP 155 g 155 mg–3.1 g 1 30–60 261.5 38.6 300/20.7
SW-5422-220-SP 300 g 300 mg–6.0 g 1 40–80 223.5 61.4 300/20.7
SW-5422-330-SP 420 g 420 mg–8.4 g 1 40–80 280.2 61.4 250/17.2

※ Compatible with all flash chromatography systems on the market.

High-efficiency spherical ARG, 20-45 µm, 100 Å (NEW Product)
 (carbon content 8%, end-capping, surface area 320 m2/g, loading capacity 0.1–2%)

Item Number Column Size Sample Size Units/Box Flow Rate (mL/min) Cartridge Length (mm) Cartridge ID (mm) Max. Pressure (psi/bar)
SW-5622-004-SP 5.4 g 5.4 mg–108 mg 2 5–15 113.8 12.4 400/27.5
SW-5622-012-SP 20 g 20 mg–0.40 g 1 10–25 134.8 21.4 400/27.5
SW-5622-025-SP 33 g 33 mg–0.66 g 1 10–25 184 21.4 400/27.5
SW-5622-040-SP 48 g 48 mg–0.96 g 1 15–30 184.4 26.7 400/27.5
SW-5622-080-SP 105 g 105 mg–2.1 g 1 20–50 257.4 31.2 350/24.0
SW-5622-120-SP 155 g 155 mg–3.1 g 1 30–60 261.5 38.6 300/20.7
SW-5622-220-SP 300 g 300 mg–6.0 g 1 40–80 223.5 61.4 300/20.7
SW-5622-330-SP 420 g 420 mg–8.4 g 1 40–80 280.2 61.4 250/17.2

※ Compatible with all flash chromatography systems on the market.

High-efficiency spherical C8, 20-45 µm, 100 Å
 (carbon content 7%, end-capping, surface area 320 m2/g, loading capacity 0.1–2%)

Item Number Column Size Sample Size Units/Box Flow Rate (mL/min) Cartridge Length (mm) Cartridge ID (mm) Max. Pressure (psi/bar)
SW-5822-004-SP 5.4 g 5.4 mg–108 mg 2 5–15 113.8 12.4 400/27.5
SW-5822-012-SP 20 g 20 mg–0.40 g 1 10–25 134.8 21.4 400/27.5
SW-5822-025-SP 33 g 33 mg–0.66 g 1 10–25 184 21.4 400/27.5
SW-5822-040-SP 48 g 48 mg–0.96 g 1 15–30 184.4 26.7 400/27.5
SW-5822-080-SP 105 g 105 mg–2.1 g 1 20–50 257.4 31.2 350/24.0
SW-5822-120-SP 155 g 155 mg–3.1 g 1 30–60 261.5 38.6 300/20.7
SW-5822-220-SP 300 g 300 mg–6.0 g 1 40–80 223.5 61.4 300/20.7
SW-5822-330-SP 420 g 420 mg–8.4 g 1 40–80 280.2 61.4 250/17.2

※ Compatible with all flash chromatography systems on the market.

High-efficiency spherical C8(AQ), 20-45 µm, 100 Å (NEW Product)
 (carbon content 7%, end-capping, surface area 320 m2/g, loading capacity 0.1–2%)

Item Number Column Size Sample Size Units/Box Flow Rate (mL/min) Cartridge Length (mm) Cartridge ID (mm) Max. Pressure (psi/bar)
SW-5822-004-SP(AQ) 5.4 g 5.4 mg–108 mg 2 5–15 113.8 12.4 400/27.5
SW-5822-012-SP(AQ) 20 g 20 mg–0.40 g 1 10–25 134.8 21.4 400/27.5
SW-5822-025-SP(AQ) 33 g 33 mg–0.66 g 1 10–25 184 21.4 400/27.5
SW-5822-040-SP(AQ) 48 g 48 mg–0.96 g 1 15–30 184.4 26.7 400/27.5
SW-5822-080-SP(AQ) 105 g 105 mg–2.1 g 1 20–50 257.4 31.2 350/24.0
SW-5822-120-SP(AQ) 155 g 155 mg–3.1 g 1 30–60 261.5 38.6 300/20.7
SW-5822-220-SP(AQ) 300 g 300 mg–6.0 g 1 40–80 223.5 61.4 300/20.7
SW-5822-330-SP(AQ) 420 g 420 mg–8.4 g 1 40–80 280.2 61.4 250/17.2

※ Compatible with all flash chromatography systems on the market.

High-efficiency spherical Diol, 20-45 µm, 100 Å
 (carbon content 5%, end-capping, surface area 320 m2/g, loading capacity 0.1–2%)

Item Number Column Size Sample Size Units/Box Flow Rate (mL/min) Cartridge Length (mm) Cartridge ID (mm) Max. Pressure (psi/bar)
SW-5922-004-SP 5.4 g 5.4 mg–108 mg 2 5–15 113.8 12.4 400/27.5
SW-5922-012-SP 20 g 20 mg–0.40 g 1 10–25 134.8 21.4 400/27.5
SW-5922-025-SP 33 g 33 mg–0.66 g 1 10–25 184 21.4 400/27.5
SW-5922-040-SP 48 g 48 mg–0.96 g 1 15–30 184.4 26.7 400/27.5
SW-5922-080-SP 105 g 105 mg–2.1 g 1 20–50 257.4 31.2 350/24.0
SW-5922-120-SP 155 g 155 mg–3.1 g 1 30–60 261.5 38.6 300/20.7
SW-5922-220-SP 300 g 300 mg–6.0 g 1 40–80 223.5 61.4 300/20.7
SW-5922-330-SP 420 g 420 mg–8.4 g 1 40–80 280.2 61.4 250/17.2

※ Compatible with all flash chromatography systems on the market.

High-efficiency spherical Phenyl, 20-45 µm, 100 Å 
 (carbon content 10%, end-capping, surface area 320 m2/g, loading capacity 0.1–2%)

Item Number Column Size Sample Size Units/Box Flow Rate (mL/min) Cartridge Length (mm) Cartridge ID (mm) Max. Pressure (psi/bar)
SW-5B22-004-SP 5.4 g 5.4 mg–108 mg 2 5–15 113.8 12.4 400/27.5
SW-5B22-012-SP 20 g 20 mg–0.40 g 1 10–25 134.8 21.4 400/27.5
SW-5B22-025-SP 33 g 33 mg–0.66 g 1 10–25 184 21.4 400/27.5
SW-5B22-040-SP 48 g 48 mg–0.96 g 1 15–30 184.4 26.7 400/27.5
SW-5B22-080-SP 105 g 105 mg–2.1 g 1 20–50 257.4 31.2 350/24.0
SW-5B22-120-SP 155 g 155 mg–3.1 g 1 30–60 261.5 38.6 300/20.7
SW-5B22-220-SP 300 g 300 mg–6.0 g 1 40–80 223.5 61.4 300/20.7
SW-5B22-330-SP 420 g 420 mg–8.4 g 1 40–80 280.2 61.4 250/17.2

※ Compatible with all flash chromatography systems on the market.

High-efficiency spherical Phenyl-Hexyl, 20-45 µm, 100 Å
 (carbon content 10%, end-capping, surface area 320 m2/g, loading capacity 0.1–2%)

Item Number Column Size Sample Size Units/Box Flow Rate (mL/min) Cartridge Length (mm) Cartridge ID (mm) Max. Pressure (psi/bar)
SW-5C22-004-SP 5.4 g 5.4 mg–108 mg 2 5–15 113.8 12.4 400/27.5
SW-5C22-012-SP 20 g 20 mg–0.40 g 1 10–25 134.8 21.4 400/27.5
SW-5C22-025-SP 33 g 33 mg–0.66 g 1 10–25 184 21.4 400/27.5
SW-5C22-040-SP 48 g 48 mg–0.96 g 1 15–30 184.4 26.7 400/27.5
SW-5C22-080-SP 105 g 105 mg–2.1 g 1 20–50 257.4 31.2 350/24.0
SW-5C22-120-SP 155 g 155 mg–3.1 g 1 30–60 261.5 38.6 300/20.7
SW-5C22-220-SP 300 g 300 mg–6.0 g 1 40–80 223.5 61.4 300/20.7
SW-5C22-330-SP 420 g 420 mg–8.4 g 1 40–80 280.2 61.4 250/17.2

※ Compatible with all flash chromatography systems on the market.

Ultra-pure irregular NH2, 40-63 µm, 60 Å
 (amino content 1.3 mmol/g, end-capping, surface area 500 m2/g, loading capacity 0.1–2%)

Item Number Column Size Sample Size Units/Box Flow Rate (mL/min) Cartridge Length (mm) Cartridge ID (mm) Max. Pressure (psi/bar)
SW-5501-004-IR 5.9 g 5.9 mg–118 mg 2 10–20 113.8 12.4 400/27.5
SW-5501-012-IR 23 g 23 mg–0.46 g 1 15–30 134.8 21.4 400/27.5
SW-5501-025-IR 38 g 38 mg–0.76 g 1 15–30 184 21.4 400/27.5
SW-5501-040-IR 55 g 55 mg–1.1 g 1 20–40 184.4 26.7 400/27.5
SW-5501-080-IR 122 g 122 mg–2.5 g 1 30–60 257.4 31.2 350/24.0
SW-5501-120-IR 180 g 180 mg–3.6 g 1 40–80 261.5 38.6 300/20.7
SW-5501-220-IR 340 g 340 mg–6.8 g 1 50–100 223.5 61.4 300/20.7
SW-5501-330-IR 475 g 475 mg–9.5 g 1 50–100 280.2 61.4 250/17.2

※ Compatible with all flash chromatography systems on the market.

Ultra-pure irregular SAX, 40-63 µm, 60 Å
 (carbon content 8%, surface area 500 m2/g, ion-exchange capacity ≤ 0.26 meq/g)

Item Number Column Size Sample Size Units/Box Flow Rate (mL/min) Cartridge Length (mm) Cartridge ID (mm) Max. Pressure (psi/bar)
SW-5001-004-IR 5.9 g ≤ 1.53 meq 2 10–20 113.8 12.4 400/27.5
SW-5001-012-IR 23 g ≤ 5.98 meq 1 15–30 134.8 21.4 400/27.5
SW-5001-025-IR 38 g ≤ 9.88 meq 1 15–30 184 21.4 400/27.5
SW-5001-040-IR 55 g ≤ 14.30 meq 1 20–40 184.4 26.7 400/27.5
SW-5001-080-IR 122 g ≤ 31.72 meq 1 30–60 257.4 31.2 350/24.0
SW-5001-120-IR 180 g ≤ 46.80 meq 1 40–80 261.5 38.6 300/20.7
SW-5001-220-IR 340 g ≤ 88.40 meq 1 50–100 223.5 61.4 300/20.7
SW-5001-330-IR 475 g ≤ 123.50 meq 1 50–100 280.2 61.4 250/17.2

※ Compatible with all flash chromatography systems on the  market.

Ultra-pure irregular SCX, 40-63 µm, 60 Å
 (carbon content 10%, surface area 500 m2/g, ion-exchange capacity ≤ 0.34 meq/g)

Item Number Column Size Sample Size Units/Box Flow Rate (mL/min) Cartridge Length (mm) Cartridge ID (mm) Max. Pressure (psi/bar)
SW-5701-004-IR 5.9 g ≤ 2.01 meq 2 10–20 113.8 12.4 400/27.5
SW-5701-012-IR 23 g ≤ 7.82 meq 1 15–30 134.8 21.4 400/27.5
SW-5701-025-IR 38 g ≤ 12.92 meq 1 15–30 184 21.4 400/27.5
SW-5701-040-IR 55 g ≤ 18.70 meq 1 20–40 184.4 26.7 400/27.5
SW-5701-080-IR 122 g ≤ 41.48 meq 1 30–60 257.4 31.2 350/24.0
SW-5701-120-IR 180 g ≤ 61.20 meq 1 40–80 261.5 38.6 300/20.7
SW-5701-220-IR 340 g ≤ 115.60 meq 1 50–100 223.5 61.4 300/20.7
SW-5701-330-IR 475 g ≤ 161.50 meq 1 50–100 280.2 61.4 250/17.2

※ Compatible with all flash chromatography systems on the market.


  • Previous:
  • Next:

    • AN001-The Purification of Hydrophilic Compounds by SepaFlash™ HILIC Cartridges
      AN001-The Purification of Hydrophilic Compounds by SepaFlash™ HILIC Cartridges
    • AN003-The Application of SepaFlash™ HILIC Cartridges in Synthetic Intermediates Purification
      AN003-The Application of SepaFlash™ HILIC Cartridges in Synthetic Intermediates Purification
    • AN004-The Choice of Mobile Phase in Reversed Phase Flash Chromatography
      AN004-The Choice of Mobile Phase in Reversed Phase Flash Chromatography
    •  AN008-The Exploration of Preparative Method Scaling Up by SepaFlash™ Reversed-Phase Columns
      AN008-The Exploration of Preparative Method Scaling Up by SepaFlash™ Reversed-Phase Columns
    • AN010-The Application of SepaFlash™ Reversed Phase Cartridges for Very Polar and Low Soluble Samples
      AN010-The Application of SepaFlash™ Reversed Phase Cartridges for Very Polar and Low Soluble Samples
    • AN014_The Improvement of the Resolution by Column Stacking and Its Application
      AN014_The Improvement of the Resolution by Column Stacking and Its Application
    • AN015_Hydrophobic Phase Collapse, AQ Reversed Phase Chromatography Columns
      AN015_Hydrophobic Phase Collapse, AQ Reversed Phase Chromatography Columns
    •  AN016_The Application of SepaFlash™ Strong Cation Exchange Chromatography Columns in the Purification of Alkaline Compounds
      AN016_The Application of SepaFlash™ Strong Cation Exchange Chromatography Columns in the Purification of Alkaline Compounds
    • AN017-The Purification of Taxus Extract by SepaBean™​ machine
      AN017-The Purification of Taxus Extract by SepaBean™​ machine
    •  AN018_The Application of C18AQ Columns in the Purification of Strong Polar Peptides
      AN018_The Application of C18AQ Columns in the Purification of Strong Polar Peptides
    • AN019_The Purification of Highly Polar Impurities in Antibiotics by C18AQ Columns
      AN019_The Purification of Highly Polar Impurities in Antibiotics by C18AQ Columns
    • AN020-The Application of SepaFlash™​ Strong Anion Exchange Chromatography Columns in the Purification of Acidic Compounds
      AN020-The Application of SepaFlash™​ Strong Anion Exchange Chromatography Columns in the Purification of Acidic Compounds
    • AN024_The Application of Orthogonal Chromatography for the Purification of Synthetic Pharmaceutical Intermediates
      AN024_The Application of Orthogonal Chromatography for the Purification of Synthetic Pharmaceutical Intermediates
    • AN026_The Application of SepaFlash™​ HILIC ARG Cartridge for the Purification of Strong Polar Thiazide Compound
      AN026_The Application of SepaFlash™​ HILIC ARG Cartridge for the Purification of Strong Polar Thiazide Compound
    •  AN027_SepaFlash™​ HILIC ARG cartridge and Its Application in the Purification of Oligosaccharides
      AN027_SepaFlash™​ HILIC ARG cartridge and Its Application in the Purification of Oligosaccharides
    • AN028_User Guide for Using, Cleaning and Storage of SepaFlash™​ Bonded Series Flash Columns
      AN028_User Guide for Using, Cleaning and Storage of SepaFlash™​ Bonded Series Flash Columns
    • AN029_SepaFlash™​ C18AQ Cartridge and Its Application in the Purification of Glutamine Derivatives
      AN029_SepaFlash™​ C18AQ Cartridge and Its Application in the Purification of Glutamine Derivatives
    • AN033_SepaFlash™​ HILIC ARG Cartridge and Its Application in the Purification of Amino Acid Derivatives
      AN033_SepaFlash™​ HILIC ARG Cartridge and Its Application in the Purification of Amino Acid Derivatives
    • AN036_SepaFlash™​ C18AQ Cartridge and Its Application in the Sample Desalting
      AN036_SepaFlash™​ C18AQ Cartridge and Its Application in the Sample Desalting
    • AN-SS-003 Facile Purification of large-scale steric selected bicyclic carbohydrates by SepaBean™ machine
      AN-SS-003 Facile Purification of large-scale steric selected bicyclic carbohydrates by SepaBean™ machine
    • AN-SS-006 Separation of CBD and THC by SepaFlash™ Spherical C18 Columns
      AN-SS-006 Separation of CBD and THC by SepaFlash™ Spherical C18 Columns
    Write your message here and send it to us