SepaBean™ machine L
SepaBean machine L 1000LP | |||
Item No. | SPBL01501000-0 | SPBL01501000-1 | SPBL14501000-2 |
Detector | Fixed wavelength (254nm) DAD UV detector | DAD 200-400nm UV Detector | DAD 200-800 nm UV Detector |
Maximum Pressure | Up to 150 psi (10.3 bar) | ||
SepaBean machine L 1000MP | |||
Item No. | SPBL14501000-0 | SPBL14501000-1 | SPBL14501000-2 |
Detector | Fixed wavelength (254nm) DAD UV detector | DAD 200-400nm UV Detector | DAD 200-800 nm UV Detector |
Maximum Pressure | Up to 1450 psi (99.97 bar) | ||
General Parameter | |||
Flow rate | 50 - 1000 ml/min | ||
Gradients | Four solvents binary with 3rd solvent as modifier | ||
Sample loading method | Optional, Manual Sample Loading Pump module | ||
Fraction collector | Optional, Switching valve Sample collection module | ||
Air purge | Yes | ||
Column holder | Optional, fit for 800-3000g flash columns | ||
Optional, fit for 800g,3kg, 5kg and 10kg flash columns | |||
Control device | wireless operation through mobile devices | ||
Gradient types | isocratic, linear, step | ||
Flowcell path length | 0.3 mm (default); 2.4 mm (optional). | ||
Spectral display | single/dual/all-wavelengths* | ||
Fraction collection method | all, waste, threshold, slope, time | ||
Certificate | CE |
Wireless Operation Through Mobile Devices
The flexible wireless control method is especially suitable for separation experiments that need to be protected from light or placed in an isolator.
Power Failure Recovery
The built-in power-off recovery function in the software minimizes the loss caused by accidental power failure.
Separation Method Recommendation
The software has a built-in separation method database that automatically recommends the most appropriate separation method based on the key information entered by the user, thereby improving work efficiency.
Column holder module
Optional column holder can cover more column types from 800g-10kg.
Fraction Collector
Inside pipe is up to 8 which can fit various requirements for the collection of components.
Local Network Data Sharing
Multiple instruments could form a local area network to facilitate internal data sharing and resource optimization in the laboratory.
21-CFR Part 11 Compliance
The control software complies with FDA requirements for system safety (21-CFR Part 11), making the instrument more suitable for pharmaceutical R&D companies and laboratories.
Smart purification system makes the purification easier
The smart flash chromatography system SepaBean™ machine L launched by Santai Technologies has the built-in feature of separation method recommendation. Even the beginners or non-professional chromatography operators could easily complete the purification task.
Smart purification with “Touch & GO” simplicity
SepaBean™ machine L is operated through mobile device, with iconized UI, it is simple enough for the beginner and non-professionals to complete routine separation, but also sophisticated enough for the professional or guru to complete or optimized a complex separation.
Built-In Method Database — Knowledge Retained
Researchers around the world spent numerous resources to develop methods of separating and purifying compound mixtures, whether it’s synthesized mixtures, or extracts from natural products, these valuable methods are usually stored in single location, isolated, disconnected, and become “information island” over the time. Unlike traditional flash instrument, SepaBean™ machine L employs database and distributed computing technology to retain and share these methods across secured organizational network:
● Patented SepaBean™ machine L system has built-in relational database to store separation methods, researchers can query existing or update new separation method simply using compound name, structure or project code.
● SepaBean™ machine L is network ready, multiple instruments within an organization can form a private channel, so that separation methods can be shared across the entire organization, authorized researchers can access and run these methods directly without having to re-develop the methods.
● SepaBean™ machine L can discover and connect to peer instrument automatically, once multiple instruments are connected, data is automatically synced, researchers can access their methods in any connected instrument from any location.
-
AN032_The Purification of Diastereomers by SepaFlash™ C18 Reversed Phase Cartridge
-
AN-SS-003 Facile Purification of large-scale steric selected bicyclic carbohydrates by SepaBean™ machine
-
AN-SS-005 Extraction Method Development for Cannabidiolic Acid from Cannabis sativa L. Using SepaBean™ Flash Chromatography Systems
-
SepaBean machine L Introduction
-
SepaBean machine L Operation Guide
-
SepaBean machine L Installation Guide
-
SepaBean Machine Catalog EN
-
SepaBean machine L Flyer