Gutandukanya ™
Umuyoboro urukurikirane rwa Flash Inkingi zikorwa hamwe na carridge imwe nkurukurikirane rwa HP ariko zipakiwe na ultrapire, ubuziranenge cyangwa imikorere-yo hejuru cyangwa urwego rwo hejuru cyangwa urwego rwo hejuru cyangwa urwego rwo hejuru rwa silica. Uru rukurikirane rwibicuruzwa rushobora gutanga umubabaro muburyo butandukanye kugirango uhaze neza ibisabwa kubakoresha batandukanye.
※ Biboneka muburyo butandukanye.
Umuvuduko ukabije wahawe 400 psi.
Gukosore: Inshuro 20 (ugereranije).
※ gusimbuza ubukungu kugirango utegure hplc.
※ Guhura nibikenewe bitandukanye kubisukuye.
Ultra-kurebera C18 idasanzwe, 40-63 μm, 60 å
.2/ g, ubushobozi bwo gupakira 0.1-2%)
Umubare w'ikintu | Ingano y'inkingi | Ingano yicyitegererezo | Ibice / agasanduku | Igipimo cyurugendo (ml / min) | Uburebure bwa Cartridge (MM) | Indangamuntu (MM) | Max. Igitutu (psi / akabari) |
Sw-5201-004-ir | 5.9 g | 5.9 MG-118 MG | 2 | 10-20 | 113.8 | 12.4 | 400/18.5 |
Sw-5201-012-ir | 23 g | 23mg-0.46g | 1 | 15-30 | 134.8 | 21.4 | 400/18.5 |
Sw-5201-025-ir | 38 g | 38 mg-0.76 g | 1 | 15-30 | 184 | 21.4 | 400/18.5 |
Sw-5201-040-ir | 55 g | 55 mg-1.1 g | 1 | 20-40 | 184.4 | 26.7 | 400/18.5 |
Sw-5201-080-ir | 122 G. | 122 mg-2.5 g | 1 | 30-60 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5201-120-ir | 180 g | 180 mg-3.6 g | 1 | 40-80 | 261.5 | 38.6 | 300 / 20.7 |
Sw-5201-220-ir | 340 g | 340 mg-6.8 g | 1 | 50-100 | 223.5 | 61.4 | 300 / 20.7 |
Sw-5201-330-ir | 475 g | 475 mg-9.5 g | 1 | 50-100 | 280.2 | 61.4 | 250 / 17.2 |
Guhuza na sisitemu zose za flaromatogramgraphy ku isoko.
Ultra-kurebera C18 idasanzwe, 40-63 μm, 90 å
(Ibirimo bya karubone2/ g, ubushobozi bwo gupakira 0.1-2%)
Umubare w'ikintu | Ingano y'inkingi | Ingano yicyitegererezo | Ibice / agasanduku | Igipimo cyurugendo (ml / min) | Uburebure bwa Cartridge (MM) | Indangamuntu (MM) | Max. Igitutu (psi / akabari) |
Sw-5211-004-ir | 5.2 g | 5.2 MG-104 MG | 2 | 10-20 | 113.8 | 12.4 | 400/18.5 |
Sw-5211-012-ir | 20 g | 20 mg-0.40 g | 1 | 15-30 | 134.8 | 21.4 | 400/18.5 |
Sw-5211-025-ir | 33 g | 33 mg-0.66 g | 1 | 15-30 | 184 | 21.4 | 400/18.5 |
Sw-5211-040-ir | 48 g | 48 mg-0.96 g | 1 | 20-40 | 184.4 | 26.7 | 400/18.5 |
Sw-5211-080-ir | 105 g | 105 mg-2.1 g | 1 | 30-60 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5211-120-ir | 155 g | 155 mg-3.1 g | 1 | 40-80 | 261.5 | 38.6 | 300 / 20.7 |
Sw-5211-220-ir | 295 g | 295 mg-5.9 g | 1 | 50-100 | 223.5 | 61.4 | 300 / 20.7 |
Sw-5211-330-ir | 420 G. | 420 mg-8.4 g | 1 | 50-100 | 280.2 | 61.4 | 250 / 17.2 |
Guhuza na sisitemu zose za flaromatogramgraphy ku isoko.
Ultra-Yera-Yera C18, 40-60 μm, 120 å
.
Umubare w'ikintu | Ingano y'inkingi | Ingano yicyitegererezo | Ibice / agasanduku | Igipimo cyurugendo (ml / min) | Uburebure bwa Cartridge (MM) | Indangamuntu (MM) | Max. Igitutu (psi / akabari) |
SW-5231-004-SP | 4.5 g | 4.5 mg-68 mg | 2 | 10-20 | 113.8 | 12.4 | 400/18.5 |
SW-5231-012-SP | 18 g | 18 mg-0.27 g | 1 | 15-30 | 134.8 | 21.4 | 400/18.5 |
SW-5231-025-SP | 28 g | 28 mg-0.42 g | 1 | 15-30 | 184 | 21.4 | 400/18.5 |
Sw-5231-040-SP | 40 g | 40 mg-0.60 g | 1 | 20-40 | 184.4 | 26.7 | 400/18.5 |
Sw-5231-080-sp | 90 g | 90 mg-1.35 g | 1 | 30-60 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5231-120-SP | 130 g | 130 mg-1.95 g | 1 | 40-80 | 261.5 | 38.6 | 300 / 20.7 |
SW-5231-220-SP | 245 g | 245 mg-3.68 g | 1 | 50-100 | 223.5 | 61.4 | 300 / 20.7 |
SW-523-330-SP | 350 g | 350 mg-5.25 g | 1 | 50-100 | 280.2 | 61.4 | 250 / 17.2 |
Guhuza na sisitemu zose za flaromatogramgraphy ku isoko.
Gukora neza Spficial C18, 30-50 μm, 120 å
.2/ g, ubushobozi bwo gupakira 0.1-2%)
Umubare w'ikintu | Ingano y'inkingi | Ingano yicyitegererezo | Ibice / agasanduku | Igipimo cyurugendo (ml / min) | Uburebure bwa Cartridge (MM) | Indangamuntu (MM) | Max. Igitutu (psi / akabari) |
SW-5232-004-SP | 4.3 g | 4.3 mg-86 mg | 2 | 5-15 | 113.8 | 12.4 | 400/18.5 |
Sw-5232-012-sp | 16 g | 16 mg-0.32 g | 1 | 10-25 | 134.8 | 21.4 | 400/18.5 |
SW-5232-025-SP | 26 g | 26 mg-0.52 g | 1 | 10-25 | 184 | 21.4 | 400/18.5 |
Sw-5232-040-SP | 39 g | 39 mg-0.78 g | 1 | 15-30 | 184.4 | 26.7 | 400/18.5 |
Sw-5232-080-sp | 85 g | 85 mg-1.7 g | 1 | 20-50 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5232-120-SP | 125 g | 125 mg-2.5 g | 1 | 30-60 | 261.5 | 38.6 | 300 / 20.7 |
SW-5232-220-SP | 240 g | 240 mg-4.8 g | 1 | 40-80 | 223.5 | 61.4 | 300 / 20.7 |
SW-5232-330-SP | 335 g | 335 mg-6.7 g | 1 | 40-80 | 280.2 | 61.4 | 250 / 17.2 |
Guhuza na sisitemu zose za flaromatogramgraphy ku isoko.
Ultra-Yera-Spherical C18, 40-75 μm, 100 å
.2/ g, ubushobozi bwo gupakira 0.1-1.5%)
Umubare w'ikintu | Ingano y'inkingi | Ingano yicyitegererezo | Ibice / agasanduku | Igipimo cyurugendo (ml / min) | Uburebure bwa Cartridge (MM) | Indangamuntu (MM) | Max. Igitutu (psi / akabari) |
SW-5221-004-SP | 4.6 g | 4.6 mg-69 mg | 2 | 10-20 | 113.8 | 12.4 | 400/18.5 |
Sw-5221-012-sp | 18 g | 18 mg-0.27 g | 1 | 15-30 | 134.8 | 21.4 | 400/18.5 |
Sw-5221-025-SP | 30 g | 30 mg-0.45 g | 1 | 15-30 | 184 | 21.4 | 400/18.5 |
Sw-5221-040-SP | 43 G. | 43 mg-0.65 g | 1 | 20-40 | 184.4 | 26.7 | 400/18.5 |
Sw-5221-080-sp | 95 g | 95 mg-1.43 g | 1 | 30-60 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5221-120-SP | 142 g | 142 mg-2.13 g | 1 | 40-80 | 261.5 | 38.6 | 300 / 20.7 |
SW-5221-220-SP | 265 g | 265 mg-3.98 g | 1 | 50-100 | 223.5 | 61.4 | 300 / 20.7 |
SW-5221-330-SP | 385 g | 385 mg-5.78 g | 1 | 50-100 | 280.2 | 61.4 | 250 / 17.2 |
Guhuza na sisitemu zose za flaromatogramgraphy ku isoko.
Gukora neza Spherical C18, 20-45 μm, 100 å
.2/ g, ubushobozi bwo gupakira 0.1-2%)
Umubare w'ikintu | Ingano y'inkingi | Ingano yicyitegererezo | Ibice / agasanduku | Igipimo cyurugendo (ml / min) | Uburebure bwa Cartridge (MM) | Indangamuntu (MM) | Max. Igitutu (psi / akabari) |
SW-5222-004-SP | 5.4 g | 5.4 MG-108 MG | 2 | 5-15 | 113.8 | 12.4 | 400/18.5 |
Sw-5222-012-sp | 20 g | 20 mg-0.40 g | 1 | 10-25 | 134.8 | 21.4 | 400/18.5 |
SW-5222-025-SP | 33 g | 33 mg-0.66 g | 1 | 10-25 | 184 | 21.4 | 400/18.5 |
Sw-5222-040-SP | 48 g | 48 mg-0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400/18.5 |
Sw-5222-080-sp | 105 g | 105 mg-2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5222-120-SP | 155 g | 155 mg-3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300 / 20.7 |
SW-5222-220-SP | 300 g | 300 mg-6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300 / 20.7 |
SW-5222-330-SP | 420 G. | 420 mg-8.4 g | 1 | 40-80 | 280.2 | 61.4 | 250 / 17.2 |
Guhuza na sisitemu zose za flaromatogramgraphy ku isoko.
Gukora neza Spherical C18 (AQ), 20-45 μm, 100 å (ibicuruzwa bishya)
.2/ g, ubushobozi bwo gupakira 0.1-2%)
Umubare w'ikintu | Ingano y'inkingi | Ingano yicyitegererezo | Ibice / agasanduku | Igipimo cyurugendo (ml / min) | Uburebure bwa Cartridge (MM) | Indangamuntu (MM) | Max. Igitutu (psi / akabari) |
SW-5222-004-SP (AQ) | 5.4 g | 5.4 MG-108 MG | 2 | 5-15 | 113.8 | 12.4 | 400/18.5 |
SW-5222-012-SP (AQ) | 20 g | 20 mg-0.40 g | 1 | 10-25 | 134.8 | 21.4 | 400/18.5 |
SW-5222-025-SP (AQ) | 33 g | 33 mg-0.66 g | 1 | 10-25 | 184 | 21.4 | 400/18.5 |
Sw-5222-040-SP (AQ) | 48 g | 48 mg-0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400/18.5 |
Sw-5222-080-sp (aq) | 105 g | 105 mg-2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5222-120-SP (AQ) | 155 g | 155 mg-3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300 / 20.7 |
SW-5222-220-SP (AQ) | 300 g | 300 mg-6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300 / 20.7 |
SW-5222-330-SP (AQ) | 420 G. | 420 mg-8.4 g | 1 | 40-80 | 280.2 | 61.4 | 250 / 17.2 |
Guhuza na sisitemu zose za flaromatogramgraphy ku isoko.
Gukora neza Spherical C18, 15 μm, 100 å
.2/ g, ubushobozi bwo gupakira 0.1-2%)
Umubare w'ikintu | Ingano y'inkingi | Ingano yicyitegererezo | Ibice / agasanduku | Igipimo cyurugendo (ml / min) | Uburebure bwa Cartridge (MM) | Indangamuntu (MM) | Max. Igitutu (psi / akabari) |
SW-5223-004-SP | 5.4 g | 5.4 MG-108 MG | 2 | 5-15 | 113.8 | 12.4 | 400/18.5 |
Sw-5223-012-sp | 20 g | 20 mg-0.40 g | 1 | 10-25 | 134.8 | 21.4 | 400/18.5 |
SW-5223-025-SP | 33 g | 33 mg-0.66 g | 1 | 10-25 | 184 | 21.4 | 400/18.5 |
Sw-5223-040-SP | 48 g | 48 mg-0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400/18.5 |
Sw-5223-080-sp | 105 g | 105 mg-2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350 / 24.0 |
SW-5223-120-SP | 155 g | 155 mg-3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300 / 20.7 |
SW-5223-220-SP | 290 g | 290 mg-5.8 g | 1 | 40-80 | 223.5 | 61.4 | 300 / 20.7 |
Sw-5223-330-sp | 410 g | 410 mg-8.2 g | 1 | 40-80 | 280.2 | 61.4 | 250 / 17.2 |
Guhuza na sisitemu zose za flaromatogramgraphy ku isoko.
Gukora neza Spherical CN, 20-45 μm, 100 å
.2/ g, ubushobozi bwo gupakira 0.1-2%)
Umubare w'ikintu | Ingano y'inkingi | Ingano yicyitegererezo | Ibice / agasanduku | Igipimo cyurugendo (ml / min) | Uburebure bwa Cartridge (MM) | Indangamuntu (MM) | Max. Igitutu (psi / akabari) |
SW-5322-004-SP | 5.4 g | 5.4 MG-108 MG | 2 | 5-15 | 113.8 | 12.4 | 400/18.5 |
SW-5322-012-SP | 20 g | 20 mg-0.40 g | 1 | 10-25 | 134.8 | 21.4 | 400/18.5 |
SW-5322-025-SP | 33 g | 33 mg-0.66 g | 1 | 10-25 | 184 | 21.4 | 400/18.5 |
SW-5322-040-SP | 48 g | 48 mg-0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400/18.5 |
Sw-5322-080-sp | 105 g | 105 mg-2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5322-120-SP | 155 g | 155 mg-3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300 / 20.7 |
SW-5322-220-SP | 300 g | 300 mg-6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300 / 20.7 |
SW-5322-330-SP | 420 G. | 420 mg-8.4 g | 1 | 40-80 | 280.2 | 61.4 | 250 / 17.2 |
Guhuza na sisitemu zose za flaromatogramgraphy ku isoko.
Gukora neza Spherical C4, 20-45 μm, 100 å
.2/ g, ubushobozi bwo gupakira 0.1-2%)
Umubare w'ikintu | Ingano y'inkingi | Ingano yicyitegererezo | Ibice / agasanduku | Igipimo cyurugendo (ml / min) | Uburebure bwa Cartridge (MM) | Indangamuntu (MM) | Max. Igitutu (psi / akabari) |
SW-5422-004-SP | 5.4 g | 5.4 MG-108 MG | 2 | 5-15 | 113.8 | 12.4 | 400/18.5 |
SW-5422-012-SP | 20 g | 20 mg-0.40 g | 1 | 10-25 | 134.8 | 21.4 | 400/18.5 |
SW-5422-025-SP | 33 g | 33 mg-0.66 g | 1 | 10-25 | 184 | 21.4 | 400/18.5 |
Sw-5422-040-SP | 48 g | 48 mg-0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400/18.5 |
Sw-5422-080-sp | 105 g | 105 mg-2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5422-120-SP | 155 g | 155 mg-3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300 / 20.7 |
SW-5422-220-SP | 300 g | 300 mg-6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300 / 20.7 |
SW-5422-330-SP | 420 G. | 420 mg-8.4 g | 1 | 40-80 | 280.2 | 61.4 | 250 / 17.2 |
Guhuza na sisitemu zose za flaromatogramgraphy ku isoko.
Gukora neza ARG, 20-45 μm, 100 å (ibicuruzwa bishya)
.2/ g, ubushobozi bwo gupakira 0.1-2%)
Umubare w'ikintu | Ingano y'inkingi | Ingano yicyitegererezo | Ibice / agasanduku | Igipimo cyurugendo (ml / min) | Uburebure bwa Cartridge (MM) | Indangamuntu (MM) | Max. Igitutu (psi / akabari) |
SW-5622-004-SP | 5.4 g | 5.4 MG-108 MG | 2 | 5-15 | 113.8 | 12.4 | 400/18.5 |
Sw-5622-012-sp | 20 g | 20 mg-0.40 g | 1 | 10-25 | 134.8 | 21.4 | 400/18.5 |
SW-5622-025-SP | 33 g | 33 mg-0.66 g | 1 | 10-25 | 184 | 21.4 | 400/18.5 |
Sw-5622-040-SP | 48 g | 48 mg-0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400/18.5 |
Sw-5622-080-sp | 105 g | 105 mg-2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5622-120-SP | 155 g | 155 mg-3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300 / 20.7 |
Sw-5622-220-SP | 300 g | 300 mg-6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300 / 20.7 |
SW-5622-330-SP | 420 G. | 420 mg-8.4 g | 1 | 40-80 | 280.2 | 61.4 | 250 / 17.2 |
Guhuza na sisitemu zose za flaromatogramgraphy ku isoko.
Gukora neza Spficial C8, 20-45 μm, 100 å
.2/ g, ubushobozi bwo gupakira 0.1-2%)
Umubare w'ikintu | Ingano y'inkingi | Ingano yicyitegererezo | Ibice / agasanduku | Igipimo cyurugendo (ml / min) | Uburebure bwa Cartridge (MM) | Indangamuntu (MM) | Max. Igitutu (psi / akabari) |
SW-5822-004-SP | 5.4 g | 5.4 MG-108 MG | 2 | 5-15 | 113.8 | 12.4 | 400/18.5 |
Sw-5822-012-sp | 20 g | 20 mg-0.40 g | 1 | 10-25 | 134.8 | 21.4 | 400/18.5 |
Sw-5822-025-SP | 33 g | 33 mg-0.66 g | 1 | 10-25 | 184 | 21.4 | 400/18.5 |
Sw-5822-040-SP | 48 g | 48 mg-0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400/18.5 |
Sw-5822-080-sp | 105 g | 105 mg-2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5822-120-SP | 155 g | 155 mg-3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300 / 20.7 |
SW-5822-220-SP | 300 g | 300 mg-6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300 / 20.7 |
SW-5822-330-SP | 420 G. | 420 mg-8.4 g | 1 | 40-80 | 280.2 | 61.4 | 250 / 17.2 |
Guhuza na sisitemu zose za flaromatogramgraphy ku isoko.
Gukora neza Spherical C8 (AQ), 20-45 μm, 100 å (ibicuruzwa bishya)
.2/ g, ubushobozi bwo gupakira 0.1-2%)
Umubare w'ikintu | Ingano y'inkingi | Ingano yicyitegererezo | Ibice / agasanduku | Igipimo cyurugendo (ml / min) | Uburebure bwa Cartridge (MM) | Indangamuntu (MM) | Max. Igitutu (psi / akabari) |
SW-5822-004-SP (AQ) | 5.4 g | 5.4 MG-108 MG | 2 | 5-15 | 113.8 | 12.4 | 400/18.5 |
SW-5822-012-SP (AQ) | 20 g | 20 mg-0.40 g | 1 | 10-25 | 134.8 | 21.4 | 400/18.5 |
SW-5822-025-SP (AQ) | 33 g | 33 mg-0.66 g | 1 | 10-25 | 184 | 21.4 | 400/18.5 |
Sw-5822-040-SP (AQ) | 48 g | 48 mg-0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400/18.5 |
Sw-5822-080-sp (aq) | 105 g | 105 mg-2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350 / 24.0 |
SW-5822-120-SP (AQ) | 155 g | 155 mg-3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300 / 20.7 |
SW-5822-220-SP (AQ) | 300 g | 300 mg-6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300 / 20.7 |
SW-5822-330-SP (AQ) | 420 G. | 420 mg-8.4 g | 1 | 40-80 | 280.2 | 61.4 | 250 / 17.2 |
Guhuza na sisitemu zose za flaromatogramgraphy ku isoko.
Imikorere-miremire ya Spherical Diol, 20-45 μm, 100 å
.2/ g, ubushobozi bwo gupakira 0.1-2%)
Umubare w'ikintu | Ingano y'inkingi | Ingano yicyitegererezo | Ibice / agasanduku | Igipimo cyurugendo (ml / min) | Uburebure bwa Cartridge (MM) | Indangamuntu (MM) | Max. Igitutu (psi / akabari) |
SW-5922-004-SP | 5.4 g | 5.4 MG-108 MG | 2 | 5-15 | 113.8 | 12.4 | 400/18.5 |
SW-5922-012-SP | 20 g | 20 mg-0.40 g | 1 | 10-25 | 134.8 | 21.4 | 400/18.5 |
SW-5922-025-SP | 33 g | 33 mg-0.66 g | 1 | 10-25 | 184 | 21.4 | 400/18.5 |
Sw-5922-040-SP | 48 g | 48 mg-0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400/18.5 |
Sw-5922-080-sp | 105 g | 105 mg-2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350 / 24.0 |
Sw-592-120-SP | 155 g | 155 mg-3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300 / 20.7 |
SW-5922-220-SP | 300 g | 300 mg-6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300 / 20.7 |
SW-5922-330-SP | 420 G. | 420 mg-8.4 g | 1 | 40-80 | 280.2 | 61.4 | 250 / 17.2 |
Guhuza na sisitemu zose za flaromatogramgraphy ku isoko.
Gukora neza Spficial Phenyl, 20-45 μm, 100 å
.2/ g, ubushobozi bwo gupakira 0.1-2%)
Umubare w'ikintu | Ingano y'inkingi | Ingano yicyitegererezo | Ibice / agasanduku | Igipimo cyurugendo (ml / min) | Uburebure bwa Cartridge (MM) | Indangamuntu (MM) | Max. Igitutu (psi / akabari) |
SW-5b22-004-SP | 5.4 g | 5.4 MG-108 MG | 2 | 5-15 | 113.8 | 12.4 | 400/18.5 |
Sw-5b22-012-sp | 20 g | 20 mg-0.40 g | 1 | 10-25 | 134.8 | 21.4 | 400/18.5 |
Sw-5b22-025-sp | 33 g | 33 mg-0.66 g | 1 | 10-25 | 184 | 21.4 | 400/18.5 |
SW-5b22-040-SP | 48 g | 48 mg-0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400/18.5 |
Sw-5b22-080-sp | 105 g | 105 mg-2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350 / 24.0 |
SW-5b2-12-120-SP | 155 g | 155 mg-3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300 / 20.7 |
Sw-5b22-220-SP | 300 g | 300 mg-6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300 / 20.7 |
Sw-5b22-330-sp | 420 G. | 420 mg-8.4 g | 1 | 40-80 | 280.2 | 61.4 | 250 / 17.2 |
Guhuza na sisitemu zose za flaromatogramgraphy ku isoko.
Gukora neza Spherical Phenyl-Hexyl, 20-45 μm, 100 å
.2/ g, ubushobozi bwo gupakira 0.1-2%)
Umubare w'ikintu | Ingano y'inkingi | Ingano yicyitegererezo | Ibice / agasanduku | Igipimo cyurugendo (ml / min) | Uburebure bwa Cartridge (MM) | Indangamuntu (MM) | Max. Igitutu (psi / akabari) |
SW-5C22-004-SP | 5.4 g | 5.4 MG-108 MG | 2 | 5-15 | 113.8 | 12.4 | 400/18.5 |
SW-5C22-012-SP | 20 g | 20 mg-0.40 g | 1 | 10-25 | 134.8 | 21.4 | 400/18.5 |
SW-5C22-025-SP | 33 g | 33 mg-0.66 g | 1 | 10-25 | 184 | 21.4 | 400/18.5 |
SW-5C22-040-SP | 48 g | 48 mg-0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400/18.5 |
Sw-5c2-080-sp | 105 g | 105 mg-2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350 / 24.0 |
SW-5C22-120-SP | 155 g | 155 mg-3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300 / 20.7 |
SW-5C22-220-SP | 300 g | 300 mg-6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300 / 20.7 |
SW-5C22-330-SP | 420 G. | 420 mg-8.4 g | 1 | 40-80 | 280.2 | 61.4 | 250 / 17.2 |
Guhuza na sisitemu zose za flaromatogramgraphy ku isoko.
Ultra-yera ntari nh2, 40-63 μm, 60 å
.2/ g, ubushobozi bwo gupakira 0.1-2%)
Umubare w'ikintu | Ingano y'inkingi | Ingano yicyitegererezo | Ibice / agasanduku | Igipimo cyurugendo (ml / min) | Uburebure bwa Cartridge (MM) | Indangamuntu (MM) | Max. Igitutu (psi / akabari) |
Sw-5501-004-ir | 5.9 g | 5.9 MG-118 MG | 2 | 10-20 | 113.8 | 12.4 | 400/18.5 |
Sw-5501-012-ir | 23 g | 23 mg-0.46 g | 1 | 15-30 | 134.8 | 21.4 | 400/18.5 |
Sw-5501-025-ir | 38 g | 38 mg-0.76 g | 1 | 15-30 | 184 | 21.4 | 400/18.5 |
Sw-5501-040-ir | 55 g | 55 mg-1.1 g | 1 | 20-40 | 184.4 | 26.7 | 400/18.5 |
Sw-5501-080-ir | 122 G. | 122 mg-2.5 g | 1 | 30-60 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5501-120-ir | 180 g | 180 mg-3.6 g | 1 | 40-80 | 261.5 | 38.6 | 300 / 20.7 |
Sw-5501-220-ir | 340 g | 340 mg-6.8 g | 1 | 50-100 | 223.5 | 61.4 | 300 / 20.7 |
Sw-5501-330-ir | 475 g | 475 mg-9.5 g | 1 | 50-100 | 280.2 | 61.4 | 250 / 17.2 |
Guhuza na sisitemu zose za flaromatogramgraphy ku isoko.
Ultra-Yera Isura idasanzwe, 40-63 μm, 60 å
(Ibirimo bya karubone 8%, ubuso bwa 500 m2/ g, ion-guhanishwa ubushobozi ≤ 0.26 Meq / G)
Umubare w'ikintu | Ingano y'inkingi | Ingano yicyitegererezo | Ibice / agasanduku | Igipimo cyurugendo (ml / min) | Uburebure bwa Cartridge (MM) | Indangamuntu (MM) | Max. Igitutu (psi / akabari) |
Sw-5001-004-ir | 5.9 g | Meq | 2 | 10-20 | 113.8 | 12.4 | 400/18.5 |
Sw-5001-012-ir | 23 g | Meq98 Meq | 1 | 15-30 | 134.8 | 21.4 | 400/18.5 |
Sw-5001-025-ir | 38 g | Meq | 1 | 15-30 | 184 | 21.4 | 400/18.5 |
Sw-5001-040-ir | 55 g | ≤ 14.30 Meq | 1 | 20-40 | 184.4 | 26.7 | 400/18.5 |
Sw-5001-080-ir | 122 G. | ≤ 31.72 Meq | 1 | 30-60 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5001-120-ir | 180 g | ≤ 46.80 Meq | 1 | 40-80 | 261.5 | 38.6 | 300 / 20.7 |
Sw-5001-220-ir | 340 g | ≤ 88.40 Meq | 1 | 50-100 | 223.5 | 61.4 | 300 / 20.7 |
Sw-5001-330-ir | 475 g | ≤ 123.50 Meq | 1 | 50-100 | 280.2 | 61.4 | 250 / 17.2 |
Guhuza na sisitemu zose za flaromatogramgraphy ku isoko.
Ultra-yera scx scx, 40-63 μm, 60 å
(Ibirimo bya karubone 10%, ubuso bwa 500 m2/ g, ion-guhanishwa ubushobozi ≤ 0.34 Meq / G)
Umubare w'ikintu | Ingano y'inkingi | Ingano yicyitegererezo | Ibice / agasanduku | Igipimo cyurugendo (ml / min) | Uburebure bwa Cartridge (MM) | Indangamuntu (MM) | Max. Igitutu (psi / akabari) |
Sw-5701-004-ir | 5.9 g | ≤ 2.01 Meq | 2 | 10-20 | 113.8 | 12.4 | 400/18.5 |
Sw-5701-012-ir | 23 g | Meq | 1 | 15-30 | 134.8 | 21.4 | 400/18.5 |
Sw-5701-025-ir | 38 g | Meq92 | 1 | 15-30 | 184 | 21.4 | 400/18.5 |
Sw-5701-040-ir | 55 g | ≤ 18.70 Meq | 1 | 20-40 | 184.4 | 26.7 | 400/18.5 |
Sw-5701-080-ir | 122 G. | ≤ 41.48 Meq | 1 | 30-60 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5701-120-ir | 180 g | ≤ 61.20 Meq | 1 | 40-80 | 261.5 | 38.6 | 300 / 20.7 |
Sw-5701-220-ir | 340 g | ≤ 115.60 Meq | 1 | 50-100 | 223.5 | 61.4 | 300 / 20.7 |
Sw-5701-330-ir | 475 g | ≤ 161.50 Meq | 1 | 50-100 | 280.2 | 61.4 | 250 / 17.2 |
Guhuza na sisitemu zose za flaromatogramgraphy ku isoko.
- Gutandukanya inkingi ya katalogal en
- AN001-Gusukura Ibice bya Hydrophilic na Gutandukanya ™ Ikarito ya Hilic
- AN003-Gusaba Gutandukanya Nto
- AN004 - Guhitamo icyiciro cya mobile muri Phere gihindukira Flash chromatography
- AN008 - Ubushakashatsi bwimyiteguro yo guteganya butanga na Startflash ™ Inkingi
- An010 - Gusaba Gutandukanya Ikarito yicyiciro cya Plase kuri Polar cyane hamwe nicyitegererezo cyoroheje
- AN014_Iterambere ryicyemezo kubice byibasiwe na porogaramu yayo
- An015_hydrophophic icyiciro cyo gusenyuka, aq yahinduye icyiciro cyimpapuro
- An016_ibikorwa byo gutandukanya ™ ivugurura rya chromatografiya thromatografi mu isuku ya alkaline ibice bya alkaline
- An017 - Kwezwa kwa tagisi ya sepabenaan ™ imashini
- An018_ibikorwa bya C18AQ Inkingi mugusukura guteka muri parilande
- AN019_Izarangiza umwanda wa polay muri antibiyotike na c18AQ inkingi
- AN020 - Gusaba Gutandukanya ™ ihanahana Anion Guhana Inkingi ya Chromatografi mu kwezwa n'ibihugu bya acide
- AN024_Gukoresha Orthogonal Chromatography yo kwezwa kwa farumatike ya flarnthetic
- AN026_Gusaba Gutandukanya Ikarita ™ Hilic Arg Cartridge yo kweza uruganda rukomeye rwa polar thiazide
- AN027_Sseppaflash ™ Ikarito ya ARG na Porogaramu yacyo mugusukura olisacchaside
- AN028_Umuyobozi wo Gukoresha, Gusukura no Kubika Byumurongo ™ Lose Urukurikirane rwa Flash Inkingi
- AN029_Sseflash ™ C18AQ Cartridge hamwe no gusaba kwayo mugusukura ibikomoka kuri Glutamine
- AN033_SsepAflash ™ ikarito ya arg na porogaramu yayo mugusukura aside acino
- AN036_Sseflash ™ C18AQ Cartridge hamwe na porogaramu yayo mubyitegererezo
- An-SS-003 yoza isura ya steric nini ya poric yatoranijwe na bicyclict ya Bicyclict na Sepabean ™ imashini
- An-SS-006 Gutandukana na CBD na Thc ukoresheje Gutandukanya ™ Inkingi C18