Brevis descriptio:

Series HP columnae mico iuncta sunt et permittunt altiores pressiones usque ad 400 psi, promptae faciliores adaptor convenientiam cum quavis ratio mico in foro offerre.

Fusionis series High resolutio, oeconomica magis et salvifica

Platinum series Melior constantia et iteratio, pressio dorsi humilis, alta resolutio

※Ruby series Larger volumen loading, usus minus solvens, superior separationis gradus


Product Detail

Applicationem

Video

catalogue

Product Introduction

Series HP columnae mico iuncta sunt ac permittunt ut altioris pressionis usque ad 400 psi. Praesto adaptor faciliorem reddit compatibilitatem cum aliqua systemate mico in foro. Haec series praebet Luer-Lok in et Luer-Lok e flexibilitatem convenientis columnae positis. Cum praecellens efficacia gel silica conferta (irregularis, 25-40 µm, 60 ; sphaerica, 20-45 µm, 70 ), haec series egregiam resolutionem praebet super cartridges mico conventionali.

solidus, corpus polypropylene nummum cum muris densis ad salutem
libere eligere silica irregularis vel silica sphaerica secundum personalem preference
Conspicue melius resolutio et altior specimen loading facultatem
Sphaerica silica meliorem efficiendi rationem praebet sine incremento systematis backpressure

Beneficia sphaericae silicae gel

Nam sphaerica silica gel, qualitas stricte moderatur a materia rudis ad opus perfectum, multum efficit multiplicabilitatem altam et specificationes arcte moderatas.

Constantia, commendatio, reproducibilitas
Nulla contagione minus backpressure
Superius senatus
Symmetrica cacumina nihil tendentem
Superius sample facultatem loading

sphaericus

HP Fusion Series - Excelsa resolutio, oeconomica magis et salvifica

Summus vis irregularis silica, 25−40 µm, 60(Superficiem area D m *2/g, pH 6.5-7.5, facultatem loading 0.1-15%)

Item Number Columna Location Magnitudine exempli (g) Fluunt Rate(mL/min) Adapter Longitudo (cm) Adapter ID (mm) Maximilianus. Pressura (psi / talea) Quantitas per Box
Parvus Magnum
SW-5102-004 4g 4mg-0.6g 15-30 113.8 12.4 400/27.5 24 120
SW-5102-012 12g 12mg-1.8g 25-50 134.8 21.4 400/27.5 24 108
SW-5102-025 25g 25mg-3.8g 25-50 184 21.4 400/27.5 18 72
SW-5102-040 40g 40mg-6.0g 30-60 184.4 26.7 400/27.5 12 48
SW-5102-080 80g 80mg-12g 40-80 257.4 31.2 350/24.0 10 20
SW-5102-120 120g 120mg-18g 45–90 261.5 38.6 300/20.7 8 16
SW-5102-220 220g 220mg-33g 60-120 223.5 61.4 300/20.7 4 8
SW-5102-330 330g 330mg-50g 60-120 280.2 61.4 250/17.2 3 6
SW-5102-800 800g 800mg-120g 50-100 382.9 78.2 100/6.9 3 -
SW-5102-1600 1600g 1.6g-240g 50-100 432.4 103.8 100/6.9 2 -
SW-5102-3000 3kg 3g-450g 50-100 509.5 127.5 100/6.9 1 -
SW-5102-5000 5kg 5g-750g 50-100 770 127.5 100/6.9 1 -
SW-5102-010K 10kg 10g-1.5kg 50-100 850 172.5 100/6.9 1 -

※ Compatible cum omnibus systematibus chromatographiae mico in foro.

Applicationem of *SepaFlash™HP Fusion Series

Purificatio compositorum quae difficilia sunt dilucida chromatographia separare (ΔRf ≤ 0,2 inter maculas TLC) saepe evenit in gradibus additis sicut sequens purificatio per scalam praeparativam HPLC. Fieri potest reducere amounts additae operis ad purificationem requisitae, per singulas columnas SepaFlash positis tantum preparatis ad finem systematis chromatographiae mico finiendum.

In chromatographia liquida, species chemicae ob differentias velocitatis earum per agmen moventes separantur. Augens columna longitudo signanter solutionem augere potest. Per positis columnis finem usque ad diametrum longitudinis (L ad D) ratio augetur ut nullae majores mutationes in instrumentis et systematis solvendo sint necessariae. Saepe L ad D aucta haec satis est ad felicem separationem difficilium mixturae mixturae ob arctam compositionem retentionis temporis, quod in una columna non obtinetur. Notitia relationem linearem illustrat inter solutionem et altiorem columnam longitudinis.

HP1
HP

HP Platinum Series Constantia, iteratio, pressio dorsi humilis, alta resolutio, salvifica solvens

Ultra Pure sphaericam silicam, 40−75 µm, 70(Superficiem area D m *2/g, pH 6.0-8.0, facultatem loading 0.1-10%)

Item Number Columna Location Magnitudine exempli (g) Fluunt Rate(mL/min) Adapter Longitudo (cm) Adapter ID (mm) Maximilianus. Pressura (psi / talea) Quantitas per Box
Parvus Magnum
SW-2101-004-SP 4g 4mg-0.4g 15-40 113.8 12.4 400/27.5 24 120
SW-2101-012-SP 12g 12mg–1.2g 30-60 134.8 21.4 400/27.5 24 108
SW-2101-025-SP 25g 25mg–2.5g 30-60 184 21.4 400/27.5 18 72
SW-2101-040-SP 40g 40mg–4.0g 40-70 184.4 26.7 400/27.5 12 48
SW-2101-080-SP 80g 80mg–8.0g 50-100 257.4 31.2 350/24.0 10 20
SW-2101-120-SP 120g 120mg-12g 60-150 261.5 38.6 300/20.7 8 16
SW-2101-220-SP 220g 220mg-22g 80-220 223.5 61.4 300/20.7 4 8
SW-2101-330-SP 330g 330mg–33g 80-220 280.2 61.4 250/17.2 3 6
SW-2101-800-SP 800g 800mg-80g 50-100 382.9 78.2 100/6.9 3 -
SW-2101-1600-SP 1600g 1.6g-160g 50-100 432.4 103.8 100/6.9 2 -
SW-2101-3000-SP 3kg 3g-300g 50-100 509.5 127.5 100/6.9 1 -
SW-2101-5000-SP 5kg 5g-500g 50-100 770 127.5 100/6.9 1 -
SW-2101-010K-SP 10kg 10g-1kg 50-100 850 172.5 100/6.9 1 -

※ Compatible cum omnibus systematibus chromatographiae mico in foro.

Summus vis sphaerica silica, 20−45 µm, 70(Superficiem area D m *2/g, pH 6.0-8.0, facultatem loading 0.1-15%)

Item Number Columna Location Magnitudine exempli (g) Fluunt Rate(mL/min) Adapter Longitudo (cm) Adapter ID (mm) Maximilianus. Pressura (psi / talea) Quantitas per Box
Parvus Magnum
SW-2102-004-SP 4g 4mg-0.6g 15-30 113.8 12.4 400/27.5 24 120
SW-2102-012-SP 12g 12mg–1.8g 25-50 134.8 21.4 400/27.5 24 108
SW-2102-025-SP 25g 25mg–3.8g 25-50 184 21.4 400/27.5 18 72
SW-2102-040-SP 40g 40mg–6.0g 30-60 184.4 26.7 400/27.5 12 48
SW-2102-080-SP 80g 80mg-12g 40-80 257.4 31.2 350/24.0 10 20
SW-2102-120-SP 120g 120mg-18g 45–90 261.5 38.6 300/20.7 8 16
SW-2102-220-SP 220g 220mg–33g 60-120 223.5 61.4 300/20.7 4 8
SW-2102-330-SP 330g 330mg-50g 60-120 280.2 61.4 250/17.2 3 6
SW-2102-800-SP 800g 800mg-120g 50-100 382.9 78.2 100/6.9 3 -
SW-2102-1600-SP 1600g 1.6g-240g 50-100 432.4 103.8 100/6.9 2 -
SW-2102-3000-SP 3kg 3g-450g 50-100 509.5 127.5 100/6.9 1 -
SW-2102-5000-SP 5kg 5g-750g 50-100 770 127.5 100/6.9 1 -
SW-2102-010K-SP 10kg 10g-1.5kg 50-100 850 172.5 100/6.9 1 -

※ Compatible cum omnibus systematibus chromatographiae mico in foro.

HP Ruby Series - Volume

Summus capacitas sphaericae silicae, 50 µm, 54(area superficiei 700 m2/g, pH 6.0‒8.0, capacitatis 0.1‒30% onerantium)

Item Number Columna Location Magnitudine exempli (g) Fluunt Rate(mL/min) Adapter Longitudo (cm) Adapter ID (mm) Maximilianus. Pressura (psi / talea) Quantitas per Box
Parvus Magnum
SW-2101-004-SP(H) 4g 4mg–1.2g 15-30 113.8 12.4 400/27.5 24 120
SW-2101-012-SP(H) 12g 12mg–3.6g 25-50 134.8 21.4 400/27.5 24 108
SW-2101-025-SP(H) 25g 25mg–7.5g 25-50 184 21.4 400/27.5 18 72
SW-2101-040-SP(H) 40g 40mg-12g 30-60 184.4 26.7 400/27.5 12 48
SW-2101-080-SP(H) 80g 80mg-24g 40-80 257.4 31.2 350/24.0 10 20
SW-2101-120-SP(H) 120g 120mg–36g 45-90 261.5 38.6 300/20.7 8 16
SW-2101-220-SP(H) 220g 220mg-66g 60-120 223.5 61.4 300/20.7 4 8
SW-2101-330-SP(H) 330g 330mg–99g 60-120 280.2 61.4 250/17.2 3 6
SW-2101-800-SP(H) 800g 800mg-240g 50-100 382.9 78.2 100/6.9 3 -
SW-2101-1600-SP(H) 1600g 1.6g-480g 50-100 432.4 103.8 100/6.9 2 -
SW-2101-3000-SP(H) 3kg 3g-900g 50-100 509.5 127.5 100/6.9 1 -
SW-2101-5000-SP(H) 5kg 5g-1.5kg 50-100 770 127.5 100/6.9 1 -
SW-2101-010K-SP(H) 10kg 10g-3kg 50-100 850 172.5 100/6.9 1 -

※ Compatible cum omnibus systematibus chromatographiae mico in foro.

Summus capacitas sphaerica silica, 25 µm, 50(Superficiem area DCC m *2/g, pH 5.0-8.0, facultatem loading 0.1-30%)

Item Number Columna Location Magnitudine exempli (g) Fluunt Rate(mL/min) Adapter Longitudo (cm) Adapter ID (mm) Maximilianus. Pressura (psi / talea) Quantitas per Box
Parvus Magnum
SW-2102-004-SP(H) 4g 4mg–1.2g 15-30 113.8 12.4 400/27.5 24 120
SW-2102-012-SP(H) 12g 12mg–3.6g 25-50 134.8 21.4 400/27.5 24 108
SW-2102-025-SP(H) 25g 25mg–7.5g 25-50 184 21.4 400/27.5 18 72
SW-2102-040-SP(H) 40g 40mg-12g 30-60 184.4 26.7 400/27.5 12 48
SW-2102-080-SP(H) 80g 80mg-24g 40-80 257.4 31.2 350/24.0 10 20
SW-2102-120-SP(H) 120g 120mg–36g 45-90 261.5 38.6 300/20.7 8 16
SW-2102-220-SP(H) 220g 220mg-66g 60-120 223.5 61.4 300/20.7 4 8
SW-2102-330-SP(H) 330g 330mg–99g 60-120 280.2 61.4 250/17.2 3 6
SW-2102-800-SP(H) 800g 800mg-240g 50-100 382.9 78.2 100/6.9 3 -
SW-2102-1600-SP(H) 1600g 1.6g-480g 50-100 432.4 103.8 100/6.9 2 -
SW-2102-3000-SP(H) 3kg 3g-900g 50-100 509.5 127.5 100/6.9 1 -
SW-2102-5000-SP(H) 5kg 5g-1.5kg 50-100 770 127.5 100/6.9 1 -
SW-2102-010K-SP(H) 10kg 10g-3kg 50-100 850 172.5 100/6.9 1 -

※ Compatible cum omnibus systematibus chromatographiae mico in foro.

Summus capacitas sphaerica silica, 15 µm, 50(Superficiem area DCC m *2/g, pH 5.0-8.0, facultatem loading 0.1-30%)

Item Number Columna Location Magnitudine exempli (g) Fluunt Rate(mL/min) Adapter Longitudo (cm) Adapter ID (mm) Maximilianus. Pressura (psi / talea) Quantitas per Box
Parvus Magnum
SW-2103-004-SP(H) 4 g* 4 mg-1.2 g 10-15 113.8 12.4 400/27.5 24 120
SW-2103-012-SP(H) 12 g* 12 mg-3.6 g 15-20 134.8 21.4 400/27.5 24 108
SW-2103-025-SP(H) 25 g 25 mg-7.5 g 15-20 184 21.4 400/27.5 18 72
SW-2103-040-SP(H) 40 g 40 mg-12 g 20-30 184.4 26.7 400/27.5 12 48
SW-2103-080-SP(H) 80 g 80 mg-24 g 30-40 257.4 31.2 350/24.0 10 20
SW-2103-120-SP(H) 120 g 120 mg-36 g 35-45 261.5 38.6 300/20.7 8 16
SW-2103-220-SP(H) 220 g 220 mg-66 g 50-65 223.5 61.4 300/20.7 4 8
SW-2103-30-SP(H) 330 g 330 mg-99 g 50-65 280.2 61.4 250/17.2 3 6

※ Compatible cum omnibus systematibus chromatographiae mico in foro.

Applicationem of *SepaFlash™ HP Ruby Series

Duplex Loading Capacity of SepaFlash™ Cartridges pre-packed with high-capacity silica gel (700 m.2/g pro 50Å magnitudine) summam purificationem tradit. Summus capacitas 25 µm vel 15 µm sphaericam silicam 40% superiorem superficiei habet, duplicando facultatem onerantium superficiei silicae inferioris. Santai perpensum faciendum in SepaFlash™ columnarum duarum notarum notarum comparatarum. Proventus monstrant SepaFlash™ competitores outperforms.

HP3
HP4

  • Previous:
  • Next:

    • AN006-De Purificatione Peptide Parvi Moleculares SepaFlash™ HP Bio Series Flash Cartridge
      AN006-De Purificatione Peptide Parvi Moleculares SepaFlash™ HP Bio Series Flash Cartridge
    • AN009-Purificatio Porphyrii per apparatus SepaBean™
      AN009-Purificatio Porphyrii per apparatus SepaBean™
    • AN012-Applicatio SepaFlash Cartridges in Purificatione Diazoti Composita
      AN012-Applicatio SepaFlash Cartridges in Purificatione Diazoti Composita
    • AN021_De applicatione Columnae Stacking in Purificatione Optoelectronic Materiae Organicae
      AN021_De applicatione Columnae Stacking in Purificatione Optoelectronic Materiae Organicae
    • AN022_Higher Sample Loading facultas, Melior euismod - Applicatio SepaFlash™ Ruby High Consilium Cartridges
      AN022_Higher Sample Loading facultas, Melior euismod - Applicatio SepaFlash™ Ruby High Consilium Cartridges
    • AN023_SepaFlash™ Ruby Series High Resolution Normal Phase Silicone Column Reuse and Storage Guide
      AN023_SepaFlash™ Ruby Series High Resolution Normal Phase Silicone Column Reuse and Storage Guide
    • AN-SS-007-Reusable Santai SepaFlash™ Ruby Series Columnae Separatio usque ad C temporibus
      AN-SS-007-Reusable Santai SepaFlash™ Ruby Series Columnae Separatio usque ad C temporibus
    Epistulam tuam hic scribe et mitte nobis