Seri Berikat SepaFlash™
Kolom lampu kilat seri terikat diprodhuksi nganggo kartrid sing padha karo seri HP nanging dikemas nganggo silika ikatan UltraPure, kualitas dhuwur utawa efisiensi dhuwur. Produk seri iki bisa nawakake macem-macem sorben supaya bisa nyukupi kabutuhan pangguna sing beda.
※ Kasedhiya ing macem-macem spesifikasi.
※ Tekanan ditingkatake nganti 400 psi.
※ Bisa digunakake maneh: 20 kaping (rata-rata).
※ Panggantos ekonomi kanggo HPLC preparative.
※ Ketemu macem-macem kabutuhan kanggo pemurnian tartamtu.
C18 irregular ultra murni, 40-63 µm, 60 Å
(Kandungan karbon 17%, tutup mburi, area permukaan 500 m2/g, kapasitas muat 0,1–2%)
Nomer Item | Ukuran Kolom | Ukuran Sampel | Unit/Kotak | Laju Aliran (mL/min) | Panjang Kartrid (mm) | ID Kartrid (mm) | Maks. Tekanan (psi/bar) |
SW-5201-004-IR | 5,9 g | 5,9 mg–118 mg | 2 | 10–20 | 113.8 | 12.4 | 400/27.5 |
SW-5201-012-IR | 23 g | 23mg–0,46g | 1 | 15–30 | 134.8 | 21.4 | 400/27.5 |
SW-5201-025-IR | 38 g | 38 mg–0,76 g | 1 | 15–30 | 184 | 21.4 | 400/27.5 |
SW-5201-040-IR | 55 g | 55 mg–1,1 g | 1 | 20–40 | 184.4 | 26.7 | 400/27.5 |
SW-5201-080-IR | 122 g | 122 mg–2,5 g | 1 | 30–60 | 257.4 | 31.2 | 350/24.0 |
SW-5201-120-IR | 180 g | 180 mg–3,6 g | 1 | 40–80 | 261.5 | 38.6 | 300/20.7 |
SW-5201-220-IR | 340 g | 340 mg–6,8 g | 1 | 50–100 | 223.5 | 61.4 | 300/20.7 |
SW-5201-330-IR | 475 g | 475 mg–9,5 g | 1 | 50–100 | 280.2 | 61.4 | 250/17.2 |
※ Kompatibel karo kabeh sistem kromatografi lampu kilat ing pasar.
C18 irregular ultra murni, 40-63 µm, 90 Å
(Kandungan karbon 15%, tutup mburi, area permukaan 400 m2/g, kapasitas muat 0,1–2%)
Nomer Item | Ukuran Kolom | Ukuran Sampel | Unit/Kotak | Laju Aliran (mL/min) | Panjang Kartrid (mm) | ID Kartrid (mm) | Maks. Tekanan (psi/bar) |
SW-5211-004-IR | 5,2 g | 5,2 mg–104 mg | 2 | 10–20 | 113.8 | 12.4 | 400/27.5 |
SW-5211-012-IR | 20 g | 20 mg–0,40 g | 1 | 15–30 | 134.8 | 21.4 | 400/27.5 |
SW-5211-025-IR | 33 g | 33 mg–0,66 g | 1 | 15–30 | 184 | 21.4 | 400/27.5 |
SW-5211-040-IR | 48 g | 48 mg–0,96 g | 1 | 20–40 | 184.4 | 26.7 | 400/27.5 |
SW-5211-080-IR | 105 g | 105 mg–2,1 g | 1 | 30–60 | 257.4 | 31.2 | 350/24.0 |
SW-5211-120-IR | 155 g | 155 mg–3,1 g | 1 | 40–80 | 261.5 | 38.6 | 300/20.7 |
SW-5211-220-IR | 295 g | 295 mg–5,9 g | 1 | 50–100 | 223.5 | 61.4 | 300/20.7 |
SW-5211-330-IR | 420 g | 420 mg–8,4 g | 1 | 50–100 | 280.2 | 61.4 | 250/17.2 |
※ Kompatibel karo kabeh sistem kromatografi lampu kilat ing pasar.
Bola ultra murni C18, 40-60 µm, 120 Å
(Kandungan karbon 17%, end-capping, area permukaan 300 m2/g, kapasitas muat 0,1–1,5%)
Nomer Item | Ukuran Kolom | Ukuran Sampel | Unit/Kotak | Laju Aliran (mL/min) | Panjang Kartrid (mm) | ID Kartrid (mm) | Maks. Tekanan (psi/bar) |
SW-5231-004-SP | 4,5 g | 4,5 mg–68 mg | 2 | 10–20 | 113.8 | 12.4 | 400/27.5 |
SW-5231-012-SP | 18 g | 18 mg–0,27 g | 1 | 15–30 | 134.8 | 21.4 | 400/27.5 |
SW-5231-025-SP | 28 g | 28 mg–0,42 g | 1 | 15–30 | 184 | 21.4 | 400/27.5 |
SW-5231-040-SP | 40 g | 40 mg–0,60 g | 1 | 20–40 | 184.4 | 26.7 | 400/27.5 |
SW-5231-080-SP | 90 g | 90 mg–1,35 g | 1 | 30–60 | 257.4 | 31.2 | 350/24.0 |
SW-5231-120-SP | 130 g | 130 mg–1,95 g | 1 | 40–80 | 261.5 | 38.6 | 300/20.7 |
SW-5231-220-SP | 245 g | 245 mg–3,68 g | 1 | 50–100 | 223.5 | 61.4 | 300/20.7 |
SW-5231-330-SP | 350 g | 350 mg–5,25 g | 1 | 50–100 | 280.2 | 61.4 | 250/17.2 |
※ Kompatibel karo kabeh sistem kromatografi lampu kilat ing pasar.
Efisiensi dhuwur bola C18, 30-50 µm, 120 Å
(Kandungan karbon 17%, tutup mburi, area permukaan 300 m2/g, kapasitas muat 0,1–2%)
Nomer Item | Ukuran Kolom | Ukuran Sampel | Unit/Kotak | Laju Aliran (mL/min) | Panjang Kartrid (mm) | ID Kartrid (mm) | Maks. Tekanan (psi/bar) |
SW-5232-004-SP | 4,3 g | 4,3 mg–86 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5232-012-SP | 16 g | 16 mg–0,32 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5232-025-SP | 26 g | 26 mg–0,52 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5232-040-SP | 39 g | 39 mg–0,78 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5232-080-SP | 85 g | 85 mg–1,7 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5232-120-SP | 125 g | 125 mg–2,5 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5232-220-SP | 240 g | 240 mg–4,8 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5232-330-SP | 335 g | 335 mg–6,7 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ Kompatibel karo kabeh sistem kromatografi lampu kilat ing pasar.
Bola ultra murni C18, 40-75 µm, 100 Å
(Kandungan karbon 17%, tutup mburi, area permukaan 300 m2/g, kapasitas muat 0,1–1,5%)
Nomer Item | Ukuran Kolom | Ukuran Sampel | Unit/Kotak | Laju Aliran (mL/min) | Panjang Kartrid (mm) | ID Kartrid (mm) | Maks. Tekanan (psi/bar) |
SW-5221-004-SP | 4,6 g | 4,6 mg–69 mg | 2 | 10–20 | 113.8 | 12.4 | 400/27.5 |
SW-5221-012-SP | 18 g | 18 mg–0,27 g | 1 | 15–30 | 134.8 | 21.4 | 400/27.5 |
SW-5221-025-SP | 30 g | 30 mg–0,45 g | 1 | 15–30 | 184 | 21.4 | 400/27.5 |
SW-5221-040-SP | 43 g | 43 mg–0,65 g | 1 | 20–40 | 184.4 | 26.7 | 400/27.5 |
SW-5221-080-SP | 95 g | 95 mg–1,43 g | 1 | 30–60 | 257.4 | 31.2 | 350/24.0 |
SW-5221-120-SP | 142 g | 142 mg–2,13 g | 1 | 40–80 | 261.5 | 38.6 | 300/20.7 |
SW-5221-220-SP | 265 g | 265 mg–3,98 g | 1 | 50–100 | 223.5 | 61.4 | 300/20.7 |
SW-5221-330-SP | 385 g | 385 mg–5,78 g | 1 | 50–100 | 280.2 | 61.4 | 250/17.2 |
※ Kompatibel karo kabeh sistem kromatografi lampu kilat ing pasar.
Efisiensi dhuwur bola C18, 20-45 µm, 100 Å
(Kandungan karbon 17%, tutup mburi, area permukaan 320 m2/g, kapasitas muat 0,1–2%)
Nomer Item | Ukuran Kolom | Ukuran Sampel | Unit/Kotak | Laju Aliran (mL/min) | Panjang Kartrid (mm) | ID Kartrid (mm) | Maks. Tekanan (psi/bar) |
SW-5222-004-SP | 5,4 g | 5,4 mg–108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5222-012-SP | 20 g | 20 mg–0,40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5222-025-SP | 33 g | 33 mg–0,66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5222-040-SP | 48 g | 48 mg–0,96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5222-080-SP | 105 g | 105 mg–2,1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5222-120-SP | 155 g | 155 mg–3,1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5222-220-SP | 300 g | 300 mg–6,0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5222-330-SP | 420 g | 420 mg–8,4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ Kompatibel karo kabeh sistem kromatografi lampu kilat ing pasar.
Efisiensi tinggi bola C18(AQ), 20-45 µm, 100 Å (Produk ANYAR)
(isi karbon 10%, tutup mburi, area permukaan 320 m2/g, kapasitas muat 0,1–2%)
Nomer Item | Ukuran Kolom | Ukuran Sampel | Unit/Kotak | Laju Aliran (mL/min) | Panjang Kartrid (mm) | ID Kartrid (mm) | Maks. Tekanan (psi/bar) |
SW-5222-004-SP(AQ) | 5,4 g | 5,4 mg–108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5222-012-SP(AQ) | 20 g | 20 mg–0,40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5222-025-SP(AQ) | 33 g | 33 mg–0,66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5222-040-SP(AQ) | 48 g | 48 mg–0,96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5222-080-SP(AQ) | 105 g | 105 mg–2,1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5222-120-SP(AQ) | 155 g | 155 mg–3,1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5222-220-SP(AQ) | 300 g | 300 mg–6,0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5222-330-SP(AQ) | 420 g | 420 mg–8,4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ Kompatibel karo kabeh sistem kromatografi lampu kilat ing pasar.
Bunder efisiensi dhuwur C18, 15 µm, 100 Å
(Kandungan karbon 17%, tutup mburi, area permukaan 320 m2/g, kapasitas muat 0,1–2%)
Nomer Item | Ukuran Kolom | Ukuran Sampel | Unit/Kotak | Laju Aliran (mL/min) | Panjang Kartrid (mm) | ID Kartrid (mm) | Maks. Tekanan (psi/bar) |
SW-5223-004-SP | 5,4 g | 5,4 mg–108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5223-012-SP | 20 g | 20 mg–0,40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5223-025-SP | 33 g | 33 mg–0,66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5223-040-SP | 48 g | 48 mg–0,96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5223-080-SP | 105 g | 105 mg–2,1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5223-120-SP | 155 g | 155 mg–3,1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5223-220-SP | 290 g | 290 mg–5,8 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5223-330-SP | 410 g | 410 mg–8,2 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ Kompatibel karo kabeh sistem kromatografi lampu kilat ing pasar.
CN bola efisiensi dhuwur, 20-45 µm, 100 Å
(Kandungan karbon 5,5%, tutup mburi, area permukaan 320 m2/g, kapasitas muat 0,1–2%)
Nomer Item | Ukuran Kolom | Ukuran Sampel | Unit/Kotak | Laju Aliran (mL/min) | Panjang Kartrid (mm) | ID Kartrid (mm) | Maks. Tekanan (psi/bar) |
SW-5322-004-SP | 5,4 g | 5,4 mg–108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5322-012-SP | 20 g | 20 mg–0,40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5322-025-SP | 33 g | 33 mg–0,66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5322-040-SP | 48 g | 48 mg–0,96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5322-080-SP | 105 g | 105 mg–2,1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5322-120-SP | 155 g | 155 mg–3,1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5322-220-SP | 300 g | 300 mg–6,0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5322-330-SP | 420 g | 420 mg–8,4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ Kompatibel karo kabeh sistem kromatografi lampu kilat ing pasar.
Efisiensi dhuwur bola C4, 20-45 µm, 100 Å
(Kandungan karbon 5,8%, tutup mburi, area permukaan 320 m2/g, kapasitas muat 0,1–2%)
Nomer Item | Ukuran Kolom | Ukuran Sampel | Unit/Kotak | Laju Aliran (mL/min) | Panjang Kartrid (mm) | ID Kartrid (mm) | Maks. Tekanan (psi/bar) |
SW-5422-004-SP | 5,4 g | 5,4 mg–108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5422-012-SP | 20 g | 20 mg–0,40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5422-025-SP | 33 g | 33 mg–0,66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5422-040-SP | 48 g | 48 mg–0,96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5422-080-SP | 105 g | 105 mg–2,1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5422-120-SP | 155 g | 155 mg–3,1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5422-220-SP | 300 g | 300 mg–6,0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5422-330-SP | 420 g | 420 mg–8,4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ Kompatibel karo kabeh sistem kromatografi lampu kilat ing pasar.
ARG bola efisiensi tinggi, 20-45 µm, 100 Å (Produk ANYAR)
(Kandungan karbon 8%, tutup mburi, area permukaan 320 m2/g, kapasitas muat 0,1–2%)
Nomer Item | Ukuran Kolom | Ukuran Sampel | Unit/Kotak | Laju Aliran (mL/min) | Panjang Kartrid (mm) | ID Kartrid (mm) | Maks. Tekanan (psi/bar) |
SW-5622-004-SP | 5,4 g | 5,4 mg–108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5622-012-SP | 20 g | 20 mg–0,40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5622-025-SP | 33 g | 33 mg–0,66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5622-040-SP | 48 g | 48 mg–0,96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5622-080-SP | 105 g | 105 mg–2,1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5622-120-SP | 155 g | 155 mg–3,1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5622-220-SP | 300 g | 300 mg–6,0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5622-330-SP | 420 g | 420 mg–8,4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ Kompatibel karo kabeh sistem kromatografi lampu kilat ing pasar.
Efisiensi dhuwur bola C8, 20-45 µm, 100 Å
(Kandungan karbon 7%, tutup mburi, area permukaan 320 m2/g, kapasitas muat 0,1–2%)
Nomer Item | Ukuran Kolom | Ukuran Sampel | Unit/Kotak | Laju Aliran (mL/min) | Panjang Kartrid (mm) | ID Kartrid (mm) | Maks. Tekanan (psi/bar) |
SW-5822-004-SP | 5,4 g | 5,4 mg–108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5822-012-SP | 20 g | 20 mg–0,40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5822-025-SP | 33 g | 33 mg–0,66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5822-040-SP | 48 g | 48 mg–0,96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5822-080-SP | 105 g | 105 mg–2,1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5822-120-SP | 155 g | 155 mg–3,1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5822-220-SP | 300 g | 300 mg–6,0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5822-330-SP | 420 g | 420 mg–8,4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ Kompatibel karo kabeh sistem kromatografi lampu kilat ing pasar.
Bola Efisiensi Tinggi C8(AQ), 20-45 µm, 100 Å (Produk ANYAR)
(Kandungan karbon 7%, tutup mburi, area permukaan 320 m2/g, kapasitas muat 0,1–2%)
Nomer Item | Ukuran Kolom | Ukuran Sampel | Unit/Kotak | Laju Aliran (mL/min) | Panjang Kartrid (mm) | ID Kartrid (mm) | Maks. Tekanan (psi/bar) |
SW-5822-004-SP(AQ) | 5,4 g | 5,4 mg–108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5822-012-SP(AQ) | 20 g | 20 mg–0,40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5822-025-SP(AQ) | 33 g | 33 mg–0,66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5822-040-SP(AQ) | 48 g | 48 mg–0,96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5822-080-SP(AQ) | 105 g | 105 mg–2,1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5822-120-SP(AQ) | 155 g | 155 mg–3,1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5822-220-SP(AQ) | 300 g | 300 mg–6,0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5822-330-SP(AQ) | 420 g | 420 mg–8,4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ Kompatibel karo kabeh sistem kromatografi lampu kilat ing pasar.
Diol bola efisiensi dhuwur, 20-45 µm, 100 Å
(isi karbon 5%, tutup mburi, area permukaan 320 m2/g, kapasitas muat 0,1–2%)
Nomer Item | Ukuran Kolom | Ukuran Sampel | Unit/Kotak | Laju Aliran (mL/min) | Panjang Kartrid (mm) | ID Kartrid (mm) | Maks. Tekanan (psi/bar) |
SW-5922-004-SP | 5,4 g | 5,4 mg–108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5922-012-SP | 20 g | 20 mg–0,40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5922-025-SP | 33 g | 33 mg–0,66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5922-040-SP | 48 g | 48 mg–0,96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5922-080-SP | 105 g | 105 mg–2,1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5922-120-SP | 155 g | 155 mg–3,1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5922-220-SP | 300 g | 300 mg–6,0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5922-330-SP | 420 g | 420 mg–8,4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ Kompatibel karo kabeh sistem kromatografi lampu kilat ing pasar.
Phenyl bola efisiensi dhuwur, 20-45 µm, 100 Å
(isi karbon 10%, tutup mburi, area permukaan 320 m2/g, kapasitas muat 0,1–2%)
Nomer Item | Ukuran Kolom | Ukuran Sampel | Unit/Kotak | Laju Aliran (mL/min) | Panjang Kartrid (mm) | ID Kartrid (mm) | Maks. Tekanan (psi/bar) |
SW-5B22-004-SP | 5,4 g | 5,4 mg–108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5B22-012-SP | 20 g | 20 mg–0,40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5B22-025-SP | 33 g | 33 mg–0,66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5B22-040-SP | 48 g | 48 mg–0,96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5B22-080-SP | 105 g | 105 mg–2,1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5B22-120-SP | 155 g | 155 mg–3,1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5B22-220-SP | 300 g | 300 mg–6,0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5B22-330-SP | 420 g | 420 mg–8,4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ Kompatibel karo kabeh sistem kromatografi lampu kilat ing pasar.
Phenyl-Hexyl bola efisiensi dhuwur, 20-45 µm, 100 Å
(isi karbon 10%, tutup mburi, area permukaan 320 m2/g, kapasitas muat 0,1–2%)
Nomer Item | Ukuran Kolom | Ukuran Sampel | Unit/Kotak | Laju Aliran (mL/min) | Panjang Kartrid (mm) | ID Kartrid (mm) | Maks. Tekanan (psi/bar) |
SW-5C22-004-SP | 5,4 g | 5,4 mg–108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5C22-012-SP | 20 g | 20 mg–0,40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5C22-025-SP | 33 g | 33 mg–0,66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5C22-040-SP | 48 g | 48 mg–0,96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5C22-080-SP | 105 g | 105 mg–2,1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5C22-120-SP | 155 g | 155 mg–3,1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5C22-220-SP | 300 g | 300 mg–6,0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5C22-330-SP | 420 g | 420 mg–8,4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ Kompatibel karo kabeh sistem kromatografi lampu kilat ing pasar.
NH2 irregular ultra murni, 40-63 µm, 60 Å
(kandungan amino 1,3 mmol/g, end-capping, area permukaan 500 m2/g, kapasitas muat 0,1–2%)
Nomer Item | Ukuran Kolom | Ukuran Sampel | Unit/Kotak | Laju Aliran (mL/min) | Panjang Kartrid (mm) | ID Kartrid (mm) | Maks. Tekanan (psi/bar) |
SW-5501-004-IR | 5,9 g | 5,9 mg–118 mg | 2 | 10–20 | 113.8 | 12.4 | 400/27.5 |
SW-5501-012-IR | 23 g | 23 mg–0,46 g | 1 | 15–30 | 134.8 | 21.4 | 400/27.5 |
SW-5501-025-IR | 38 g | 38 mg–0,76 g | 1 | 15–30 | 184 | 21.4 | 400/27.5 |
SW-5501-040-IR | 55 g | 55 mg–1,1 g | 1 | 20–40 | 184.4 | 26.7 | 400/27.5 |
SW-5501-080-IR | 122 g | 122 mg–2,5 g | 1 | 30–60 | 257.4 | 31.2 | 350/24.0 |
SW-5501-120-IR | 180 g | 180 mg–3,6 g | 1 | 40–80 | 261.5 | 38.6 | 300/20.7 |
SW-5501-220-IR | 340 g | 340 mg–6,8 g | 1 | 50–100 | 223.5 | 61.4 | 300/20.7 |
SW-5501-330-IR | 475 g | 475 mg–9,5 g | 1 | 50–100 | 280.2 | 61.4 | 250/17.2 |
※ Kompatibel karo kabeh sistem kromatografi lampu kilat ing pasar.
SAX irregular ultra murni, 40-63 µm, 60 Å
(Kandungan karbon 8%, area lumahing 500 m2/g, kapasitas tukar ion ≤ 0,26 meq/g)
Nomer Item | Ukuran Kolom | Ukuran Sampel | Unit/Kotak | Laju Aliran (mL/min) | Panjang Kartrid (mm) | ID Kartrid (mm) | Maks. Tekanan (psi/bar) |
SW-5001-004-IR | 5,9 g | ≤ 1,53 meq | 2 | 10–20 | 113.8 | 12.4 | 400/27.5 |
SW-5001-012-IR | 23 g | ≤ 5,98 meq | 1 | 15–30 | 134.8 | 21.4 | 400/27.5 |
SW-5001-025-IR | 38 g | ≤ 9,88 meq | 1 | 15–30 | 184 | 21.4 | 400/27.5 |
SW-5001-040-IR | 55 g | ≤ 14.30 meq | 1 | 20–40 | 184.4 | 26.7 | 400/27.5 |
SW-5001-080-IR | 122 g | ≤ 31,72 meq | 1 | 30–60 | 257.4 | 31.2 | 350/24.0 |
SW-5001-120-IR | 180 g | ≤ 46,80 meq | 1 | 40–80 | 261.5 | 38.6 | 300/20.7 |
SW-5001-220-IR | 340 g | ≤ 88,40 meq | 1 | 50–100 | 223.5 | 61.4 | 300/20.7 |
SW-5001-330-IR | 475 g | ≤ 123,50 meq | 1 | 50–100 | 280.2 | 61.4 | 250/17.2 |
※ Kompatibel karo kabeh sistem kromatografi lampu kilat ing pasar.
SCX irregular ultra murni, 40-63 µm, 60 Å
(Kandungan karbon 10%, area lumahing 500 m2/g, kapasitas tukar ion ≤ 0,34 meq/g)
Nomer Item | Ukuran Kolom | Ukuran Sampel | Unit/Kotak | Laju Aliran (mL/min) | Panjang Kartrid (mm) | ID Kartrid (mm) | Maks. Tekanan (psi/bar) |
SW-5701-004-IR | 5,9 g | ≤ 2.01 meq | 2 | 10–20 | 113.8 | 12.4 | 400/27.5 |
SW-5701-012-IR | 23 g | ≤ 7,82 meq | 1 | 15–30 | 134.8 | 21.4 | 400/27.5 |
SW-5701-025-IR | 38 g | ≤ 12,92 meq | 1 | 15–30 | 184 | 21.4 | 400/27.5 |
SW-5701-040-IR | 55 g | ≤ 18,70 meq | 1 | 20–40 | 184.4 | 26.7 | 400/27.5 |
SW-5701-080-IR | 122 g | ≤ 41,48 meq | 1 | 30–60 | 257.4 | 31.2 | 350/24.0 |
SW-5701-120-IR | 180 g | ≤ 61,20 meq | 1 | 40–80 | 261.5 | 38.6 | 300/20.7 |
SW-5701-220-IR | 340 g | ≤ 115,60 meq | 1 | 50–100 | 223.5 | 61.4 | 300/20.7 |
SW-5701-330-IR | 475 g | ≤ 161,50 meq | 1 | 50–100 | 280.2 | 61.4 | 250/17.2 |
※ Kompatibel karo kabeh sistem kromatografi lampu kilat ing pasar.
- AN001-Pemurnian Senyawa Hidrofilik dening Kartrid HILIC SepaFlash™
- AN003-Aplikasi Kartrid HILIC SepaFlash™ ing Pemurnian Intermediet Sintetis
- AN004-Pilihan Fase Seluler ing Kromatografi Lampu Kilat Fase Terbalik
- AN008-Eksplorasi Metode Preparative Scaling Up dening SepaFlash™ Reversed-Phase Columns
- AN010-Aplikasi Kartrid Fase Terbalik SepaFlash™ kanggo Sampel Sangat Polar lan Kurang Larut
- AN014_Perbaikan Resolusi dening Numpuk Kolom lan Aplikasi
- AN015_Fase Hidrofobik Runtuh, Kolom Kromatografi Fase Terbalik AQ
- AN016_Aplikasi SepaFlash™ Strong Cation Exchange Chromatography Columns ing Pemurnian Senyawa Alkali
- AN017-Pemurnian Ekstrak Taxus dening mesin SepaBean™
- AN018_Aplikasi Kolom C18AQ ing Pemurnian Peptida Kutub Kuat
- AN019_Pemurnian Impurities Highly Polar ing Antibiotik dening C18AQ Columns
- AN020-Aplikasi SepaFlash™ Kolom Kromatografi Pertukaran Anion Kuwat ing Pemurnian Senyawa Asam
- AN024_Aplikasi Kromatografi Ortogonal kanggo Pemurnian Intermediet Farmasi Sintetis
- AN026_Aplikasi Kartrid ARG HILIC SepaFlash™ kanggo Pemurnian Senyawa Thiazide Polar Kuat
- Kartrid AN027_SepaFlash™ HILIC ARG lan Aplikasi ing Pemurnian Oligosakarida
- AN028_Pandhuan Pangguna kanggo Nggunakake, Reresik lan Panyimpenan Kolom Lampu kilat Seri Berikat SepaFlash™
- Kartrid AN029_SepaFlash™ C18AQ lan Aplikasi ing Pemurnian Derivatif Glutamin
- Kartrid ARG HILIC AN033_SepaFlash™ lan Aplikasi ing Pemurnian Turunan Asam Amino