Columns Flash ikatan diprodhuksi kanthi cartridges sing padha karo Series HP nanging dikempalken karo silika ikatan berkualitas tinggi utawa dhuwur. Produk seri iki bisa nawakake macem-macem sorbents luwih apik kanggo nyukupi syarat kanggo pangguna sing beda.
※ kasedhiya ing macem-macem spesifikasi.
※ Tekanan sing luwih apik dirating nganti 400 PSI.
※ Reusability: 20 kaping (rata-rata).
√ Ganti ekonomi kanggo HPLC SULIT.
※ Rapat macem-macem kabutuhan kanggo PUSAT.
C18 sing ora teratur C18, 40-63 μm, 60 å
(Konten karbon 17%, mburi-capping, permukaan area 500 m2/ g, ngemot kapasitas 0.1-2%)
Nomer Item | Ukuran kolom | Ukuran Sample | Unit / Kothak | Tingkat aliran (ml / min) | Dawane cartridge (mm) | ID kartrij (MM) | Max. Meksa (psi / bar) |
Sw-5201-004-ir | 5.9 g | 5.9 mg-118 mg | 2 | 10-20 | 113.8 | 12.4 | 400 / 27.5 |
Sw-5201-012-ir | 23 g | 23mg-0.46g | 1 | 15-30 | 134.8 | 21.4 | 400 / 27.5 |
Sw-5201-025-ir | 38 g | 38 mg-0.76 g | 1 | 15-30 | 184 | 21.4 | 400 / 27.5 |
Sw-5201-040-ir | 55 g | 55 mg-1.1 g | 1 | 20-40 | 184.4 | 26.7 | 400 / 27.5 |
Sw-5201-080-IR | 122 g | 122 mg-2,5 g | 1 | 30-60 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5201-120-ir | 180 g | 180 mg-3.6 g | 1 | 40-80 | 261.5 | 38.6 | 300 / 20.7 |
Sw-5201-220-ir | 340 g | 340 mg-68 g | 1 | 50-100 | 223.5 | 61.4 | 300 / 20.7 |
Sw-5201-3-ir | 475 g | 475 mg-9.5 g | 1 | 50-100 | 280.2 | 61.4 | 250 / 17.2 |
※ Kompatibel karo kabeh sistem kromatografi kilat ing pasar.
C18 sing ora teratur C18, 40-63 μm, 90 å
(Konten karbon 15%, cacing mburi, area lumahing 400 m2/ g, ngemot kapasitas 0.1-2%)
Nomer Item | Ukuran kolom | Ukuran Sample | Unit / Kothak | Tingkat aliran (ml / min) | Dawane cartridge (mm) | ID kartrij (MM) | Max. Meksa (psi / bar) |
Sw-5211-004-ir | 5.2 g | 5.2 mg-104 mg | 2 | 10-20 | 113.8 | 12.4 | 400 / 27.5 |
Sw-5211-012-ir | 20 g | 20 mg-0,40 g | 1 | 15-30 | 134.8 | 21.4 | 400 / 27.5 |
Sw-5211-025-ir | 33 g | 33 mg-0.66 g | 1 | 15-30 | 184 | 21.4 | 400 / 27.5 |
Sw-5211-040-ir | 48 g | 48 mg-0.96 g | 1 | 20-40 | 184.4 | 26.7 | 400 / 27.5 |
Sw-5211-080-IR | 105 g | 105 mg-2.1 g | 1 | 30-60 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5211-120-ir | 155 g | 155 mg-3.1 g | 1 | 40-80 | 261.5 | 38.6 | 300 / 20.7 |
Sw-5211-220-ir | 295 g | 295 mg-5,9 g | 1 | 50-100 | 223.5 | 61.4 | 300 / 20.7 |
Sw-5211-330-IR | 420 g | 420 mg-8,4 g | 1 | 50-100 | 280.2 | 61.4 | 250 / 17.2 |
※ Kompatibel karo kabeh sistem kromatografi kilat ing pasar.
C18 Spherical Ultra-Murni-murni, 40-60 μm, 120 Å
(Konten karbon 17%, mburi-capping, area lumahing 300 m2 / g, ngemot kapasitas 0,1-15%)
Nomer Item | Ukuran kolom | Ukuran Sample | Unit / Kothak | Tingkat aliran (ml / min) | Dawane cartridge (mm) | ID kartrij (MM) | Max. Meksa (psi / bar) |
Sw-5231-004-sp | 4,5 g | 4,5 mg-68 mg | 2 | 10-20 | 113.8 | 12.4 | 400 / 27.5 |
Sw-5231-012-sp | 18 g | 18 mg-0.27 g | 1 | 15-30 | 134.8 | 21.4 | 400 / 27.5 |
Sw-5231-025-sp | 28 g | 28 mg-0.42 g | 1 | 15-30 | 184 | 21.4 | 400 / 27.5 |
Sw-5231-040-sp | 40 g | 40 mg-0,60 g | 1 | 20-40 | 184.4 | 26.7 | 400 / 27.5 |
SW-5231-080-SP | 90 g | 90 mg-1,35 g | 1 | 30-60 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5231-120-sp | 130 g | 130 mg-1.95 g | 1 | 40-80 | 261.5 | 38.6 | 300 / 20.7 |
SW-5231-220-SP | 245 g | 245 mg-3.68 g | 1 | 50-100 | 223.5 | 61.4 | 300 / 20.7 |
SW-523130-SP | 350 g | 350 mg-5.25 g | 1 | 50-100 | 280.2 | 61.4 | 250 / 17.2 |
※ Kompatibel karo kabeh sistem kromatografi kilat ing pasar.
High-efisiensi C18, 30-50 μm, 120 Å
(Konten karbon 17%, mburi-capping, area lumahing 300 m2/ g, ngemot kapasitas 0.1-2%)
Nomer Item | Ukuran kolom | Ukuran Sample | Unit / Kothak | Tingkat aliran (ml / min) | Dawane cartridge (mm) | ID kartrij (MM) | Max. Meksa (psi / bar) |
Sw-5232-004-sp | 4.3 g | 4.3 mg-86 mg | 2 | 5-15 | 113.8 | 12.4 | 400 / 27.5 |
Sw-5232-012-sp | 16 g | 16 mg-0.32 g | 1 | 10-25 | 134.8 | 21.4 | 400 / 27.5 |
Sw-5232-025-sp | 26 g | 26 mg-0,5252 g | 1 | 10-25 | 184 | 21.4 | 400 / 27.5 |
Sw-5232-040-sp | 39 g | 39 mg-0.78 g | 1 | 15-30 | 184.4 | 26.7 | 400 / 27.5 |
Sw-5232-080-sp | 85 g | 85 mg-1,7 g | 1 | 20-50 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5232-120-sp | 125 g | 125 mg-2,5 g | 1 | 30-60 | 261.5 | 38.6 | 300 / 20.7 |
Sw-5232-220-sp | 240 g | 240 mg-4,8 g | 1 | 40-80 | 223.5 | 61.4 | 300 / 20.7 |
Sw-5232-3-sp | 335 g | 335 mg-6,7 g | 1 | 40-80 | 280.2 | 61.4 | 250 / 17.2 |
※ Kompatibel karo kabeh sistem kromatografi kilat ing pasar.
C18 SPHER KEDIT Ultra-murni, 40-75 μm, 100 Å
(Konten karbon 17%, mburi-capping, area lumahing 300 m2/ g, ngemot kapasitas 0,1-15%)
Nomer Item | Ukuran kolom | Ukuran Sample | Unit / Kothak | Tingkat aliran (ml / min) | Dawane cartridge (mm) | ID kartrij (MM) | Max. Meksa (psi / bar) |
Sw-5221-004-sp | 4.6 g | 4.6 mg-69 mg | 2 | 10-20 | 113.8 | 12.4 | 400 / 27.5 |
Sw-5221-012-sp | 18 g | 18 mg-0.27 g | 1 | 15-30 | 134.8 | 21.4 | 400 / 27.5 |
Sw-5221-025-sp | 30 g | 30 mg-0.45 g | 1 | 15-30 | 184 | 21.4 | 400 / 27.5 |
Sw-5221-040-sp | 43 g | 43 mg-0.65 g | 1 | 20-40 | 184.4 | 26.7 | 400 / 27.5 |
Sw-5221-080-sp | 95 g | 95 mg-1,43 g | 1 | 30-60 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5221-120-sp | 142 g | 142 mg-2.13 g | 1 | 40-80 | 261.5 | 38.6 | 300 / 20.7 |
Sw-5221-220-sp | 265 g | 265 mg-3.98 g | 1 | 50-100 | 223.5 | 61.4 | 300 / 20.7 |
Sw-5221-330-sp | 385 g | 385 mg-5.78 g | 1 | 50-100 | 280.2 | 61.4 | 250 / 17.2 |
※ Kompatibel karo kabeh sistem kromatografi kilat ing pasar.
High-efisiensi c18, 20-45 μm, 100 å
(Konten karbon 17%, mburi-capping, area lumahing 320 m2/ g, ngemot kapasitas 0.1-2%)
Nomer Item | Ukuran kolom | Ukuran Sample | Unit / Kothak | Tingkat aliran (ml / min) | Dawane cartridge (mm) | ID kartrij (MM) | Max. Meksa (psi / bar) |
Sw-5222-00444-sp | 5.4 g | 5.4 mg-108 mg | 2 | 5-15 | 113.8 | 12.4 | 400 / 27.5 |
Sw-5222-012-sp | 20 g | 20 mg-0,40 g | 1 | 10-25 | 134.8 | 21.4 | 400 / 27.5 |
Sw-5222-025-sp | 33 g | 33 mg-0.66 g | 1 | 10-25 | 184 | 21.4 | 400 / 27.5 |
Sw-5222-040-sp | 48 g | 48 mg-0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400 / 27.5 |
Sw-5222-080-sp | 105 g | 105 mg-2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5222-120-sp | 155 g | 155 mg-3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300 / 20.7 |
Sw-5222-220-sp | 300 g | 300 mg-6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300 / 20.7 |
Sw-5222-330-sp | 420 g | 420 mg-8,4 g | 1 | 40-80 | 280.2 | 61.4 | 250 / 17.2 |
※ Kompatibel karo kabeh sistem kromatografi kilat ing pasar.
High-efisiensi C18 (AQ), 20-45 μm, 100 Å (produk anyar)
(Konten karbon 10%, mburi-capping, area lumahing 320 m2/ g, ngemot kapasitas 0.1-2%)
Nomer Item | Ukuran kolom | Ukuran Sample | Unit / Kothak | Tingkat aliran (ml / min) | Dawane cartridge (mm) | ID kartrij (MM) | Max. Meksa (psi / bar) |
SW-5222-0044444444444-SP (AQ) | 5.4 g | 5.4 mg-108 mg | 2 | 5-15 | 113.8 | 12.4 | 400 / 27.5 |
SW-5222-012-SP (AQ) | 20 g | 20 mg-0,40 g | 1 | 10-25 | 134.8 | 21.4 | 400 / 27.5 |
SW-5222-025-SP (AQ) | 33 g | 33 mg-0.66 g | 1 | 10-25 | 184 | 21.4 | 400 / 27.5 |
Sw-5222-040-sp (aq) | 48 g | 48 mg-0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400 / 27.5 |
SW-5222-080-SP (AQ) | 105 g | 105 mg-2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350 / 24.0 |
SW-5222-120-SP (AQ) | 155 g | 155 mg-3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300 / 20.7 |
SW-5222-220-SP (AQ) | 300 g | 300 mg-6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300 / 20.7 |
SW-5222-330-SP (AQ) | 420 g | 420 mg-8,4 g | 1 | 40-80 | 280.2 | 61.4 | 250 / 17.2 |
※ Kompatibel karo kabeh sistem kromatografi kilat ing pasar.
High-efisiensi C18, 15 μm, 100 å
(Konten karbon 17%, mburi-capping, area lumahing 320 m2/ g, ngemot kapasitas 0.1-2%)
Nomer Item | Ukuran kolom | Ukuran Sample | Unit / Kothak | Tingkat aliran (ml / min) | Dawane cartridge (mm) | ID kartrij (MM) | Max. Meksa (psi / bar) |
Sw-5223-004-sp | 5.4 g | 5.4 mg-108 mg | 2 | 5-15 | 113.8 | 12.4 | 400 / 27.5 |
Sw-5223-012-sp | 20 g | 20 mg-0,40 g | 1 | 10-25 | 134.8 | 21.4 | 400 / 27.5 |
Sw-5223-025-sp | 33 g | 33 mg-0.66 g | 1 | 10-25 | 184 | 21.4 | 400 / 27.5 |
Sw-5223-040-sp | 48 g | 48 mg-0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400 / 27.5 |
Sw-5223-080-sp | 105 g | 105 mg-2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5223-120-sp | 155 g | 155 mg-3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300 / 20.7 |
SW-5223-220-SP | 290 g | 290 mg-5.8 g | 1 | 40-80 | 223.5 | 61.4 | 300 / 20.7 |
SW-5223-3-SP | 410 g | 410 mg-8,2 g | 1 | 40-80 | 280.2 | 61.4 | 250 / 17.2 |
※ Kompatibel karo kabeh sistem kromatografi kilat ing pasar.
CN Spherical CN, 20-45 ~μm, 100 nganti
(Konten karbon 5.5%, mburi-capping, area lumahing 320 m2/ g, ngemot kapasitas 0.1-2%)
Nomer Item | Ukuran kolom | Ukuran Sample | Unit / Kothak | Tingkat aliran (ml / min) | Dawane cartridge (mm) | ID kartrij (MM) | Max. Meksa (psi / bar) |
Sw-5322-004-sp | 5.4 g | 5.4 mg-108 mg | 2 | 5-15 | 113.8 | 12.4 | 400 / 27.5 |
Sw-5322-012-sp | 20 g | 20 mg-0,40 g | 1 | 10-25 | 134.8 | 21.4 | 400 / 27.5 |
Sw-5322-025-sp | 33 g | 33 mg-0.66 g | 1 | 10-25 | 184 | 21.4 | 400 / 27.5 |
Sw-5322-040-sp | 48 g | 48 mg-0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400 / 27.5 |
Sw-5322-080-sp | 105 g | 105 mg-2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5322-120-sp | 155 g | 155 mg-3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300 / 20.7 |
Sw-5322-220-SP | 300 g | 300 mg-6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300 / 20.7 |
Sw-5322-330-sp | 420 g | 420 mg-8,4 g | 1 | 40-80 | 280.2 | 61.4 | 250 / 17.2 |
※ Kompatibel karo kabeh sistem kromatografi kilat ing pasar.
Efisiensi High-High-efisiensi C4, 20-45 μm, 100 nganti
(Konten karbon 5.8%, mburi-capping, area lumahing 320 m2/ g, ngemot kapasitas 0.1-2%)
Nomer Item | Ukuran kolom | Ukuran Sample | Unit / Kothak | Tingkat aliran (ml / min) | Dawane cartridge (mm) | ID kartrij (MM) | Max. Meksa (psi / bar) |
Sw-5422-004-sp | 5.4 g | 5.4 mg-108 mg | 2 | 5-15 | 113.8 | 12.4 | 400 / 27.5 |
Sw-5422-012-sp | 20 g | 20 mg-0,40 g | 1 | 10-25 | 134.8 | 21.4 | 400 / 27.5 |
Sw-5422-025-sp | 33 g | 33 mg-0.66 g | 1 | 10-25 | 184 | 21.4 | 400 / 27.5 |
Sw-5422-040-sp | 48 g | 48 mg-0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400 / 27.5 |
Sw-5422-080-sp | 105 g | 105 mg-2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5422-120-sp | 155 g | 155 mg-3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300 / 20.7 |
Sw-5422-220-sp | 300 g | 300 mg-6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300 / 20.7 |
Sw-5422-33030-sp | 420 g | 420 mg-8,4 g | 1 | 40-80 | 280.2 | 61.4 | 250 / 17.2 |
※ Kompatibel karo kabeh sistem kromatografi kilat ing pasar.
Arg Spherical High-efisiensi, 20-45 μm, 100 Å (produk anyar)
(Konten karbon 8%, mburi-capping, area lumahing 320 m2/ g, ngemot kapasitas 0.1-2%)
Nomer Item | Ukuran kolom | Ukuran Sample | Unit / Kothak | Tingkat aliran (ml / min) | Dawane cartridge (mm) | ID kartrij (MM) | Max. Meksa (psi / bar) |
Sw-5622-004-sp | 5.4 g | 5.4 mg-108 mg | 2 | 5-15 | 113.8 | 12.4 | 400 / 27.5 |
Sw-5622-012-sp | 20 g | 20 mg-0,40 g | 1 | 10-25 | 134.8 | 21.4 | 400 / 27.5 |
Sw-5622-025-sp | 33 g | 33 mg-0.66 g | 1 | 10-25 | 184 | 21.4 | 400 / 27.5 |
Sw-5622-040-sp | 48 g | 48 mg-0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400 / 27.5 |
Sw-5622-080-sp | 105 g | 105 mg-2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5622-120-sp | 155 g | 155 mg-3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300 / 20.7 |
Sw-5622-220-sp | 300 g | 300 mg-6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300 / 20.7 |
Sw-5622-330-sp | 420 g | 420 mg-8,4 g | 1 | 40-80 | 280.2 | 61.4 | 250 / 17.2 |
※ Kompatibel karo kabeh sistem kromatografi kilat ing pasar.
High-efisiensi lempung C8, 20-45 μm, 100 å
(Konten karbon 7%, mburi-capping, area lumahing 320 m2/ g, ngemot kapasitas 0.1-2%)
Nomer Item | Ukuran kolom | Ukuran Sample | Unit / Kothak | Tingkat aliran (ml / min) | Dawane cartridge (mm) | ID kartrij (MM) | Max. Meksa (psi / bar) |
Sw-5822-00444-sp | 5.4 g | 5.4 mg-108 mg | 2 | 5-15 | 113.8 | 12.4 | 400 / 27.5 |
Sw-5822-012-sp | 20 g | 20 mg-0,40 g | 1 | 10-25 | 134.8 | 21.4 | 400 / 27.5 |
Sw-5822-025-sp | 33 g | 33 mg-0.66 g | 1 | 10-25 | 184 | 21.4 | 400 / 27.5 |
Sw-5822-040-sp | 48 g | 48 mg-0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400 / 27.5 |
Sw-5822-080-sp | 105 g | 105 mg-2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5822-120-sp | 155 g | 155 mg-3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300 / 20.7 |
Sw-5822-220-sp | 300 g | 300 mg-6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300 / 20.7 |
Sw-5822-330-sp | 420 g | 420 mg-8,4 g | 1 | 40-80 | 280.2 | 61.4 | 250 / 17.2 |
※ Kompatibel karo kabeh sistem kromatografi kilat ing pasar.
High-efisiensi c8 (aq), 20-45 μm, 100 Å (produk anyar)
(Konten karbon 7%, mburi-capping, area lumahing 320 m2/ g, ngemot kapasitas 0.1-2%)
Nomer Item | Ukuran kolom | Ukuran Sample | Unit / Kothak | Tingkat aliran (ml / min) | Dawane cartridge (mm) | ID kartrij (MM) | Max. Meksa (psi / bar) |
Sw-5822-0044444444444-SP (AQ) | 5.4 g | 5.4 mg-108 mg | 2 | 5-15 | 113.8 | 12.4 | 400 / 27.5 |
Sw-5822-012-sp (aq) | 20 g | 20 mg-0,40 g | 1 | 10-25 | 134.8 | 21.4 | 400 / 27.5 |
Sw-5822-025-sp (aq) | 33 g | 33 mg-0.66 g | 1 | 10-25 | 184 | 21.4 | 400 / 27.5 |
Sw-5822-040-sp (aq) | 48 g | 48 mg-0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400 / 27.5 |
SW-5822-080-SP (AQ) | 105 g | 105 mg-2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5822-120-SP (AQ) | 155 g | 155 mg-3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300 / 20.7 |
SW-5822-220-SP (AQ) | 300 g | 300 mg-6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300 / 20.7 |
SW-5822-330-SP (AQ) | 420 g | 420 mg-8,4 g | 1 | 40-80 | 280.2 | 61.4 | 250 / 17.2 |
※ Kompatibel karo kabeh sistem kromatografi kilat ing pasar.
Efisiensi dhuwur-dhuwur diol, 20-45 μm, 100 å
(Konten karbon 5%, mburi-capping, area lumahing 320 m2/ g, ngemot kapasitas 0.1-2%)
Nomer Item | Ukuran kolom | Ukuran Sample | Unit / Kothak | Tingkat aliran (ml / min) | Dawane cartridge (mm) | ID kartrij (MM) | Max. Meksa (psi / bar) |
Sw-5922-004-sp | 5.4 g | 5.4 mg-108 mg | 2 | 5-15 | 113.8 | 12.4 | 400 / 27.5 |
Sw-5922-012-sp | 20 g | 20 mg-0,40 g | 1 | 10-25 | 134.8 | 21.4 | 400 / 27.5 |
Sw-5922-025-sp | 33 g | 33 mg-0.66 g | 1 | 10-25 | 184 | 21.4 | 400 / 27.5 |
Sw-5922-040-sp | 48 g | 48 mg-0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400 / 27.5 |
Sw-5922-080-sp | 105 g | 105 mg-2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5922-120-sp | 155 g | 155 mg-3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300 / 20.7 |
Sw-5922-220-sp | 300 g | 300 mg-6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300 / 20.7 |
Sw-5922-330-sp | 420 g | 420 mg-8,4 g | 1 | 40-80 | 280.2 | 61.4 | 250 / 17.2 |
※ Kompatibel karo kabeh sistem kromatografi kilat ing pasar.
Phentrics Spherical High-efisiensi, 20-45 μm, 100 nganti
(Konten karbon 10%, mburi-capping, area lumahing 320 m2/ g, ngemot kapasitas 0.1-2%)
Nomer Item | Ukuran kolom | Ukuran Sample | Unit / Kothak | Tingkat aliran (ml / min) | Dawane cartridge (mm) | ID kartrij (MM) | Max. Meksa (psi / bar) |
Sw-5b22-004-sp | 5.4 g | 5.4 mg-108 mg | 2 | 5-15 | 113.8 | 12.4 | 400 / 27.5 |
Sw-5b22-012-sp | 20 g | 20 mg-0,40 g | 1 | 10-25 | 134.8 | 21.4 | 400 / 27.5 |
Sw-5b22-025-sp | 33 g | 33 mg-0.66 g | 1 | 10-25 | 184 | 21.4 | 400 / 27.5 |
Sw-5b22-040-sp | 48 g | 48 mg-0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400 / 27.5 |
Sw-5b22-080-sp | 105 g | 105 mg-2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5b22-120-sp | 155 g | 155 mg-3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300 / 20.7 |
Sw-5b22-220-sp | 300 g | 300 mg-6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300 / 20.7 |
Sw-5b22-330-sp | 420 g | 420 mg-8,4 g | 1 | 40-80 | 280.2 | 61.4 | 250 / 17.2 |
※ Kompatibel karo kabeh sistem kromatografi kilat ing pasar.
Efisiensi phenlicy phenyl-hemyl, 20-45 μm, 100 å
(Konten karbon 10%, mburi-capping, area lumahing 320 m2/ g, ngemot kapasitas 0.1-2%)
Nomer Item | Ukuran kolom | Ukuran Sample | Unit / Kothak | Tingkat aliran (ml / min) | Dawane cartridge (mm) | ID kartrij (MM) | Max. Meksa (psi / bar) |
Sw-5c22-004-sp | 5.4 g | 5.4 mg-108 mg | 2 | 5-15 | 113.8 | 12.4 | 400 / 27.5 |
Sw-5c22-012-sp | 20 g | 20 mg-0,40 g | 1 | 10-25 | 134.8 | 21.4 | 400 / 27.5 |
Sw-5c22-025-sp | 33 g | 33 mg-0.66 g | 1 | 10-25 | 184 | 21.4 | 400 / 27.5 |
Sw-5c22-040-sp | 48 g | 48 mg-0.96 g | 1 | 15-30 | 184.4 | 26.7 | 400 / 27.5 |
Sw-5c22-080-sp | 105 g | 105 mg-2.1 g | 1 | 20-50 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5c22-120-sp | 155 g | 155 mg-3.1 g | 1 | 30-60 | 261.5 | 38.6 | 300 / 20.7 |
Sw-5c22-220-sp | 300 g | 300 mg-6.0 g | 1 | 40-80 | 223.5 | 61.4 | 300 / 20.7 |
Sw-5c22-330-sp | 420 g | 420 mg-8,4 g | 1 | 40-80 | 280.2 | 61.4 | 250 / 17.2 |
※ Kompatibel karo kabeh sistem kromatografi kilat ing pasar.
NH2 sing ora duwe aturan sing ora tertrama-murni, 40-63 μm, 60 å
(Konten Amino 1.3 MMOL / G, End-Capping, Lumahing Area 500 m2/ g, ngemot kapasitas 0.1-2%)
Nomer Item | Ukuran kolom | Ukuran Sample | Unit / Kothak | Tingkat aliran (ml / min) | Dawane cartridge (mm) | ID kartrij (MM) | Max. Meksa (psi / bar) |
Sw-5501-004-ir | 5.9 g | 5.9 mg-118 mg | 2 | 10-20 | 113.8 | 12.4 | 400 / 27.5 |
Sw-5501-012-ir | 23 g | 23 mg-0.46 g | 1 | 15-30 | 134.8 | 21.4 | 400 / 27.5 |
Sw-5501-025-ir | 38 g | 38 mg-0.76 g | 1 | 15-30 | 184 | 21.4 | 400 / 27.5 |
Sw-5501-040-ir | 55 g | 55 mg-1.1 g | 1 | 20-40 | 184.4 | 26.7 | 400 / 27.5 |
Sw-5501-080-ir | 122 g | 122 mg-2,5 g | 1 | 30-60 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5501-120-1 | 180 g | 180 mg-3.6 g | 1 | 40-80 | 261.5 | 38.6 | 300 / 20.7 |
Sw-5501-220-1 | 340 g | 340 mg-68 g | 1 | 50-100 | 223.5 | 61.4 | 300 / 20.7 |
Sw-5501-330-ir | 475 g | 475 mg-9.5 g | 1 | 50-100 | 280.2 | 61.4 | 250 / 17.2 |
※ Kompatibel karo kabeh sistem kromatografi kilat ing pasar.
Sax Irregular Ultra-Pure, 40-63 μm, 60 å
(Konten karbon 8%, area lumahing 500 m2/ g, kapasitas ijol-ijolan ion 0.26 Meq / g)
Nomer Item | Ukuran kolom | Ukuran Sample | Unit / Kothak | Tingkat aliran (ml / min) | Dawane cartridge (mm) | ID kartrij (MM) | Max. Meksa (psi / bar) |
Sw-5001-00-ir | 5.9 g | ≤ 1.53 Meq | 2 | 10-20 | 113.8 | 12.4 | 400 / 27.5 |
Sw-5001-012-ir | 23 g | ≤ 5.98 Meq | 1 | 15-30 | 134.8 | 21.4 | 400 / 27.5 |
Sw-5001-025-ir | 38 g | ≤ 9.88 Meq | 1 | 15-30 | 184 | 21.4 | 400 / 27.5 |
Sw-5001-040-ir | 55 g | ≤ 14.30 MEQ | 1 | 20-40 | 184.4 | 26.7 | 400 / 27.5 |
Sw-5001-080-ir | 122 g | ≤ 31.72 Meq | 1 | 30-60 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5001-120 ir | 180 g | ≤ 46.80 MEQ | 1 | 40-80 | 261.5 | 38.6 | 300 / 20.7 |
Sw-5001-220-ir | 340 g | ≤ 88.40 MEQ | 1 | 50-100 | 223.5 | 61.4 | 300 / 20.7 |
Sw-500130-IR | 475 g | ≤ 123.50 Meq | 1 | 50-100 | 280.2 | 61.4 | 250 / 17.2 |
※ Kompatibel karo kabeh sistem kromatografi kilat ing pasar.
SCX sing ora duwe belanggar ultra-murni, 40-63 μm, 60 å
(Konten karbon 10%, area lumahing 500 m2/ g, kapasitas ijol-ijolan ion 0.34 meq / g)
Nomer Item | Ukuran kolom | Ukuran Sample | Unit / Kothak | Tingkat aliran (ml / min) | Dawane cartridge (mm) | ID kartrij (MM) | Max. Meksa (psi / bar) |
Sw-5701-004-ir | 5.9 g | ≤ 2.01 MEQ | 2 | 10-20 | 113.8 | 12.4 | 400 / 27.5 |
Sw-5701-012-ir | 23 g | ≤ 7,82 Meq | 1 | 15-30 | 134.8 | 21.4 | 400 / 27.5 |
Sw-5701-025-ir | 38 g | ≤ 12.92 Meq | 1 | 15-30 | 184 | 21.4 | 400 / 27.5 |
Sw-5701-040-ir | 55 g | ≤ 18.70 MEQ | 1 | 20-40 | 184.4 | 26.7 | 400 / 27.5 |
Sw-5701-080-ir | 122 g | ≤ 41.48 Meq | 1 | 30-60 | 257.4 | 31.2 | 350 / 24.0 |
Sw-5701-120-ir | 180 g | ≤ 61.20 Meq | 1 | 40-80 | 261.5 | 38.6 | 300 / 20.7 |
Sw-5701-220-ir | 340 g | ≤ 115.60 MeQ | 1 | 50-100 | 223.5 | 61.4 | 300 / 20.7 |
Sw-5701-3-ir | 475 g | ≤ 161.50 Meq | 1 | 50-100 | 280.2 | 61.4 | 250 / 17.2 |
※ Kompatibel karo kabeh sistem kromatografi kilat ing pasar.
- Katalog kolom sepaflash en
- An001 - Purifikasi senyawa hidrofilik dening Cartridges SEPFLASH ™
- An003-aplikasi saka cartridges Sepflash ™ ing pemurnian perantara sintetis
- Fase Ponsel An004-pilihan ing Chromatografi Flash Phase sing dibalik
- An008-Eksplorasi Cara Stiftative Scaling Dening Kolom Reversed-Phase Sepflash ™
- An010 - aplikasi saka cartridges Fase Revered ™ SEXFLAlH ™ kanggo conto kutub lan larut sithik
- Dandan resolusi an014_TheThe saka tumpukan kolom lan aplikasi
- Runtuh phase, AQ vase Chromatography kolom
- An016_PLIKASI CATIFLASH ACARA SEADFLASH ™ BATION LAMPIRAN COLUMNS COLUMS ING PENTING ALKALINE
- An017-Purifikasi saka pajak saka mesin sepean ™
- An018_ aplikasi kolom C18AQ ing pemurnian peptida kutub sing kuwat
- Purifikasi An019_THIFIFIAN KEDITAN KEDITAN ING Antibiotik dening COLUMNS C18AQ
- - Aplikasi saka Sepflash ™ Stion Batah Chromatografi Exchange Anion Exchange Columns ing pemurnian senyawa asam
- An024_Plitik kromografi orthogonal kanggo ngresiki farmasi farmaceutik sintetik
- An026_THLE OF SEADFLASH ™ HILIC CARTRIGHT ™ CARTRIGHT kanggo pemurnian senyawa polar thiazide sing kuwat
- Car027_sepaflash ™ Hilic Car Cartridge ™ lan aplikasi ing pemurnian oligosaccharides
- Pandhuan An028_User kanggo nggunakake, reresik lan panyimpenan Seri SEXFLASH ™ Series Flash ™
- Cartridge C18AQ ™ AN029_SEQ lan aplikasi ing pemurnian turunan glutamine
- Car033_sepaflash ™ Hilic Car Cartridge lan aplikasi ing pemurnian asam amino turunan
- Cartridge C18AQ an036_sepaflash ™ lan aplikasi ing conto conto
- Presiffikasi Facile A-SS-003 saka karbohidrat BicycLic sing gedhe banget kanthi mesin sepean ™
- Pemisahan A-SS-006 CBD lan THC dening Columns C18 Stifflash ™