SepaFlash™ agbakwunyere usoro
A na-eji otu katrij dị ka usoro HP na-arụkọ kọlụm nke ejikọta ọnụ mana ejiri silica dị elu nke dị elu ma ọ bụ arụmọrụ dị elu juputara. Ngwaahịa usoro a nwere ike ịnye ụdị sorbents dị iche iche iji mejuo ihe achọrọ maka ndị ọrụ dị iche iche.
※ Dị na nkọwapụta dị iche iche.
※ Nrụgide dị mma ruru 400 psi.
※ Reusability: ugboro 20 (nkezi).
※ Ihe nnọchi akụ na ụba maka HPLC akwadoro.
※ Zute mkpa dị iche iche maka nchacha ọcha.
Ultra-ọcha na-adịghị agafe agafe C18, 40-63 µm, 60 Å
(Ọdịnaya carbon 17%, ngwụcha ngwụcha, ebe elu 500 m2/g, ike ibu 0.1–2%)
Nọmba ihe | Nha kọlụm | Nha Nlereanya | Nkeji/ Igbe | Ọnụego ebugharị (ml/min) | Ogologo katrij (mm) | NJ cartridge (mm) | Oke. Nrụgide (psi/bar) |
SW-5201-004-IR | 5,9 g | 5.9 mg-118 mg | 2 | 10–20 | 113.8 | 12.4 | 400/27.5 |
SW-5201-012-IR | 23 g | 23 mg - 0.46 g | 1 | 15–30 | 134.8 | 21.4 | 400/27.5 |
SW-5201-025-IR | 38 g | 38 mg-0.76 g | 1 | 15–30 | 184 | 21.4 | 400/27.5 |
SW-5201-040-IR | 55 g | 55 mg-1.1 g | 1 | 20–40 | 184.4 | 26.7 | 400/27.5 |
SW-5201-080-IR | 122 g | 122 mg-2.5 g | 1 | 30–60 | 257.4 | 31.2 | 350/24.0 |
SW-5201-120-IR | 180 g | 180 mg-3.6 g | 1 | 40–80 | 261.5 | 38.6 | 300/20.7 |
SW-5201-220-IR | 340 g | 340 mg-6.8 g | 1 | 50–100 | 223.5 | 61.4 | 300/20.7 |
SW-5201-330-IR | 475 g | 475 mg-9.5 g | 1 | 50–100 | 280.2 | 61.4 | 250/17.2 |
※ dakọtara na sistemụ chromatography flash niile dị n'ahịa.
Ultra-ọcha adịghị mma C18, 40-63 µm, 90 Å
(Ọdịnaya carbon 15%, ngwụcha ngwụcha, ebe elu 400 m2/g, ike ibu 0.1–2%)
Nọmba ihe | Nha kọlụm | Nha Nlereanya | Nkeji/ Igbe | Ọnụego ebugharị (ml/min) | Ogologo katrij (mm) | NJ cartridge (mm) | Oke. Nrụgide (psi/bar) |
SW-5211-004-IR | 5,2 g | 5.2 mg-104 mg | 2 | 10–20 | 113.8 | 12.4 | 400/27.5 |
SW-5211-012-IR | 20 g | 20 mg-0.40 g | 1 | 15–30 | 134.8 | 21.4 | 400/27.5 |
SW-5211-025-IR | 33 g | 33 mg-0.66 g | 1 | 15–30 | 184 | 21.4 | 400/27.5 |
SW-5211-040-IR | 48 g | 48 mg-0.96 g | 1 | 20–40 | 184.4 | 26.7 | 400/27.5 |
SW-5211-080-IR | 105 g | 105 mg-2.1 g | 1 | 30–60 | 257.4 | 31.2 | 350/24.0 |
SW-5211-120-IR | 155 g | 155 mg-3.1 g | 1 | 40–80 | 261.5 | 38.6 | 300/20.7 |
SW-5211-220-IR | 295 g | 295 mg-5.9 g | 1 | 50–100 | 223.5 | 61.4 | 300/20.7 |
SW-5211-330-IR | 420 g | 420 mg-8.4 g | 1 | 50–100 | 280.2 | 61.4 | 250/17.2 |
※ dakọtara na sistemụ chromatography flash niile dị n'ahịa.
Ihe okirikiri dị ọcha dị ọcha C18, 40-60 µm, 120 Å
(carbon ọdịnaya 17%, njedebe-capping, elu ebe 300 m2/g, loading ike 0.1-1.5%)
Nọmba ihe | Nha kọlụm | Nha Nlereanya | Nkeji/ Igbe | Ọnụego ebugharị (ml/min) | Ogologo katrij (mm) | NJ cartridge (mm) | Oke. Nrụgide (psi/bar) |
SW-5231-004-SP | 4.5 g | 4.5 mg-68 mg | 2 | 10–20 | 113.8 | 12.4 | 400/27.5 |
SW-5231-012-SP | 18 g | 18 mg-0.27 g | 1 | 15–30 | 134.8 | 21.4 | 400/27.5 |
SW-5231-025-SP | 28 g | 28 mg-0.42 g | 1 | 15–30 | 184 | 21.4 | 400/27.5 |
SW-5231-040-SP | 40 g | 40 mg-0.60 g | 1 | 20–40 | 184.4 | 26.7 | 400/27.5 |
SW-5231-080-SP | 90 g | 90 mg-1.35 g | 1 | 30–60 | 257.4 | 31.2 | 350/24.0 |
SW-5231-120-SP | 130 g | 130 mg-1.95 g | 1 | 40–80 | 261.5 | 38.6 | 300/20.7 |
SW-5231-220-SP | 245 g | 245 mg-3.68 g | 1 | 50–100 | 223.5 | 61.4 | 300/20.7 |
SW-5231-330-SP | 350 g | 350 mg-5.25 g | 1 | 50–100 | 280.2 | 61.4 | 250/17.2 |
※ dakọtara na sistemụ chromatography flash niile dị n'ahịa.
Ịrụ ọrụ dị elu C18, 30-50 µm, 120 Å
(Ọdịnaya carbon 17%, ngwụcha ngwụcha, ebe elu 300 m2/g, ike ibu 0.1–2%)
Nọmba ihe | Nha kọlụm | Nha Nlereanya | Nkeji/ Igbe | Ọnụego ebugharị (ml/min) | Ogologo katrij (mm) | NJ cartridge (mm) | Oke. Nrụgide (psi/bar) |
SW-5232-004-SP | 4,3 g | 4.3 mg-86 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5232-012-SP | 16 g | 16 mg-0.32 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5232-025-SP | 26 g | 26 mg-0.52 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5232-040-SP | 39 g | 39 mg-0.78 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5232-080-SP | 85 g | 85 mg-1.7 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5232-120-SP | 125 g | 125 mg-2.5 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5232-220-SP | 240 g | 240 mg-4.8 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5232-330-SP | 335 g | 335 mg-6.7 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ dakọtara na sistemụ chromatography flash niile dị n'ahịa.
Obere okirikiri dị ọcha C18, 40-75 µm, 100 Å
(Ọdịnaya carbon 17%, ngwụcha ngwụcha, ebe elu 300 m2/g, ike ibu 0.1–1.5%)
Nọmba ihe | Nha kọlụm | Nha Nlereanya | Nkeji/ Igbe | Ọnụego ebugharị (ml/min) | Ogologo katrij (mm) | NJ cartridge (mm) | Oke. Nrụgide (psi/bar) |
SW-5221-004-SP | 4,6 g | 4.6 mg-69 mg | 2 | 10–20 | 113.8 | 12.4 | 400/27.5 |
SW-5221-012-SP | 18 g | 18 mg-0.27 g | 1 | 15–30 | 134.8 | 21.4 | 400/27.5 |
SW-5221-025-SP | 30 g | 30 mg-0.45 g | 1 | 15–30 | 184 | 21.4 | 400/27.5 |
SW-5221-040-SP | 43 g | 43 mg-0.65 g | 1 | 20–40 | 184.4 | 26.7 | 400/27.5 |
SW-5221-080-SP | 95 g | 95 mg-1.43 g | 1 | 30–60 | 257.4 | 31.2 | 350/24.0 |
SW-5221-120-SP | 142 g | 142 mg-2.13 g | 1 | 40–80 | 261.5 | 38.6 | 300/20.7 |
SW-5221-220-SP | 265 g | 265 mg-3.98 g | 1 | 50–100 | 223.5 | 61.4 | 300/20.7 |
SW-5221-330-SP | 385 g | 385 mg-5.78 g | 1 | 50–100 | 280.2 | 61.4 | 250/17.2 |
※ dakọtara na sistemụ chromatography flash niile dị n'ahịa.
Ịrụ ọrụ dị elu C18, 20-45 µm, 100 Å
(Ọdịnaya carbon 17%, ngwụcha ngwụcha, ebe elu 320 m2/g, ike ibu 0.1–2%)
Nọmba ihe | Nha kọlụm | Nha Nlereanya | Nkeji/ Igbe | Ọnụego ebugharị (ml/min) | Ogologo katrij (mm) | NJ cartridge (mm) | Oke. Nrụgide (psi/bar) |
SW-5222-004-SP | 5,4 g | 5.4 mg-108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5222-012-SP | 20 g | 20 mg-0.40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5222-025-SP | 33 g | 33 mg-0.66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5222-040-SP | 48 g | 48 mg-0.96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5222-080-SP | 105 g | 105 mg-2.1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5222-120-SP | 155 g | 155 mg-3.1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5222-220-SP | 300 g | 300 mg-6.0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5222-330-SP | 420 g | 420 mg-8.4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ dakọtara na sistemụ chromatography flash niile dị n'ahịa.
Ịrụ ọrụ dị elu C18 (AQ), 20-45 µm, 100 Å (ngwaahịa ọhụrụ)
(Ọdịnaya carbon 10%, ngwụcha ngwụcha, ebe elu 320 m2/g, ike ibu 0.1–2%)
Nọmba ihe | Nha kọlụm | Nha Nlereanya | Nkeji/ Igbe | Ọnụego ebugharị (ml/min) | Ogologo katrij (mm) | NJ cartridge (mm) | Oke. Nrụgide (psi/bar) |
SW-5222-004-SP(AQ) | 5,4 g | 5.4 mg-108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5222-012-SP(AQ) | 20 g | 20 mg-0.40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5222-025-SP(AQ) | 33 g | 33 mg-0.66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5222-040-SP(AQ) | 48 g | 48 mg-0.96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5222-080-SP(AQ) | 105 g | 105 mg-2.1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5222-120-SP(AQ) | 155 g | 155 mg-3.1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5222-220-SP(AQ) | 300 g | 300 mg-6.0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5222-330-SP(AQ) | 420 g | 420 mg-8.4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ dakọtara na sistemụ chromatography flash niile dị n'ahịa.
Ịrụ ọrụ dị elu C18, 15 µm, 100 Å
(Ọdịnaya carbon 17%, ngwụcha ngwụcha, ebe elu 320 m2/g, ike ibu 0.1–2%)
Nọmba ihe | Nha kọlụm | Nha Nlereanya | Nkeji/ Igbe | Ọnụego ebugharị (ml/min) | Ogologo katrij (mm) | NJ cartridge (mm) | Oke. Nrụgide (psi/bar) |
SW-5223-004-SP | 5,4 g | 5.4 mg-108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5223-012-SP | 20 g | 20 mg-0.40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5223-025-SP | 33 g | 33 mg-0.66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5223-040-SP | 48 g | 48 mg-0.96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5223-080-SP | 105 g | 105 mg-2.1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5223-120-SP | 155 g | 155 mg-3.1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5223-220-SP | 290 g | 290 mg-5.8 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5223-330-SP | 410 g | 410 mg-8.2 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ dakọtara na sistemụ chromatography flash niile dị n'ahịa.
CN okirikiri arụ ọrụ dị elu, 20-45 µm, 100 Å
(Ọdịnaya carbon 5.5%, ngwụcha ngwụcha, ebe elu 320 m2/g, ike ibu 0.1–2%)
Nọmba ihe | Nha kọlụm | Nha Nlereanya | Nkeji/ Igbe | Ọnụego ebugharị (ml/min) | Ogologo katrij (mm) | NJ cartridge (mm) | Oke. Nrụgide (psi/bar) |
SW-5322-004-SP | 5,4 g | 5.4 mg-108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5322-012-SP | 20 g | 20 mg-0.40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5322-025-SP | 33 g | 33 mg-0.66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5322-040-SP | 48 g | 48 mg-0.96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5322-080-SP | 105 g | 105 mg-2.1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5322-120-SP | 155 g | 155 mg-3.1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5322-220-SP | 300 g | 300 mg-6.0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5322-330-SP | 420 g | 420 mg-8.4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ dakọtara na sistemụ chromatography flash niile dị n'ahịa.
Spherical C4 dị elu dị elu, 20-45 µm, 100 Å
(Ọdịnaya carbon 5.8%, ngwụcha ngwụcha, ebe elu 320 m2/g, ike ibu 0.1–2%)
Nọmba ihe | Nha kọlụm | Nha Nlereanya | Nkeji/ Igbe | Ọnụego ebugharị (ml/min) | Ogologo katrij (mm) | NJ cartridge (mm) | Oke. Nrụgide (psi/bar) |
SW-5422-004-SP | 5,4 g | 5.4 mg-108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5422-012-SP | 20 g | 20 mg-0.40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5422-025-SP | 33 g | 33 mg-0.66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5422-040-SP | 48 g | 48 mg-0.96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5422-080-SP | 105 g | 105 mg-2.1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5422-120-SP | 155 g | 155 mg-3.1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5422-220-SP | 300 g | 300 mg-6.0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5422-330-SP | 420 g | 420 mg-8.4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ dakọtara na sistemụ chromatography flash niile dị n'ahịa.
ARG dị okirikiri dị elu, 20-45 µm, 100 Å (ngwaahịa ọhụrụ)
(Ọdịnaya carbon 8%, ngwụcha ngwụcha, ebe elu 320 m2/g, ike ibu 0.1–2%)
Nọmba ihe | Nha kọlụm | Nha Nlereanya | Nkeji/ Igbe | Ọnụego ebugharị (ml/min) | Ogologo katrij (mm) | NJ cartridge (mm) | Oke. Nrụgide (psi/bar) |
SW-5622-004-SP | 5,4 g | 5.4 mg-108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5622-012-SP | 20 g | 20 mg-0.40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5622-025-SP | 33 g | 33 mg-0.66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5622-040-SP | 48 g | 48 mg-0.96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5622-080-SP | 105 g | 105 mg-2.1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5622-120-SP | 155 g | 155 mg-3.1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5622-220-SP | 300 g | 300 mg-6.0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5622-330-SP | 420 g | 420 mg-8.4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ dakọtara na sistemụ chromatography flash niile dị n'ahịa.
Spherical C8 dị elu dị elu, 20-45 µm, 100 Å
(Ọdịnaya carbon 7%, ngwụcha ngwụcha, mpaghara elu 320 m2/g, ike ibu 0.1–2%)
Nọmba ihe | Nha kọlụm | Nha Nlereanya | Nkeji/ Igbe | Ọnụego ebugharị (ml/min) | Ogologo katrij (mm) | NJ cartridge (mm) | Oke. Nrụgide (psi/bar) |
SW-5822-004-SP | 5,4 g | 5.4 mg-108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5822-012-SP | 20 g | 20 mg-0.40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5822-025-SP | 33 g | 33 mg-0.66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5822-040-SP | 48 g | 48 mg-0.96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5822-080-SP | 105 g | 105 mg-2.1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5822-120-SP | 155 g | 155 mg-3.1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5822-220-SP | 300 g | 300 mg-6.0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5822-330-SP | 420 g | 420 mg-8.4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ dakọtara na sistemụ chromatography flash niile dị n'ahịa.
Ịrụ ọrụ dị elu C8 (AQ), 20-45 µm, 100 Å (ngwaahịa ọhụrụ)
(Ọdịnaya carbon 7%, ngwụcha ngwụcha, mpaghara elu 320 m2/g, ike ibu 0.1–2%)
Nọmba ihe | Nha kọlụm | Nha Nlereanya | Nkeji/ Igbe | Ọnụego ebugharị (ml/min) | Ogologo katrij (mm) | NJ cartridge (mm) | Oke. Nrụgide (psi/bar) |
SW-5822-004-SP(AQ) | 5,4 g | 5.4 mg-108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5822-012-SP(AQ) | 20 g | 20 mg-0.40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5822-025-SP(AQ) | 33 g | 33 mg-0.66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5822-040-SP(AQ) | 48 g | 48 mg-0.96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5822-080-SP(AQ) | 105 g | 105 mg-2.1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5822-120-SP(AQ) | 155 g | 155 mg-3.1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5822-220-SP(AQ) | 300 g | 300 mg-6.0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5822-330-SP(AQ) | 420 g | 420 mg-8.4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ dakọtara na sistemụ chromatography flash niile dị n'ahịa.
Diol okirikiri dị elu dị elu, 20-45 µm, 100 Å
(Ọdịnaya carbon 5%, ngwụcha ngwụcha, ebe elu 320 m2/g, ike ibu 0.1–2%)
Nọmba ihe | Nha kọlụm | Nha Nlereanya | Nkeji/ Igbe | Ọnụego ebugharị (ml/min) | Ogologo katrij (mm) | NJ cartridge (mm) | Oke. Nrụgide (psi/bar) |
SW-5922-004-SP | 5,4 g | 5.4 mg-108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5922-012-SP | 20 g | 20 mg-0.40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5922-025-SP | 33 g | 33 mg-0.66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5922-040-SP | 48 g | 48 mg-0.96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5922-080-SP | 105 g | 105 mg-2.1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5922-120-SP | 155 g | 155 mg-3.1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5922-220-SP | 300 g | 300 mg-6.0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5922-330-SP | 420 g | 420 mg-8.4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ dakọtara na sistemụ chromatography flash niile dị n'ahịa.
Phenyl dị okirikiri dị elu, 20-45 µm, 100 Å
(Ọdịnaya carbon 10%, ngwụcha ngwụcha, ebe elu 320 m2/g, ike ibu 0.1–2%)
Nọmba ihe | Nha kọlụm | Nha Nlereanya | Nkeji/ Igbe | Ọnụego ebugharị (ml/min) | Ogologo katrij (mm) | NJ cartridge (mm) | Oke. Nrụgide (psi/bar) |
SW-5B22-004-SP | 5,4 g | 5.4 mg-108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5B22-012-SP | 20 g | 20 mg-0.40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5B22-025-SP | 33 g | 33 mg-0.66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5B22-040-SP | 48 g | 48 mg-0.96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5B22-080-SP | 105 g | 105 mg-2.1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5B22-120-SP | 155 g | 155 mg-3.1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5B22-220-SP | 300 g | 300 mg-6.0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5B22-330-SP | 420 g | 420 mg-8.4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ dakọtara na sistemụ chromatography flash niile dị n'ahịa.
Spherical Phenyl-Hexyl dị elu nke ọma, 20-45 µm, 100 Å
(Ọdịnaya carbon 10%, ngwụcha ngwụcha, ebe elu 320 m2/g, ike ibu 0.1–2%)
Nọmba ihe | Nha kọlụm | Nha Nlereanya | Nkeji/ Igbe | Ọnụego ebugharị (ml/min) | Ogologo katrij (mm) | NJ cartridge (mm) | Oke. Nrụgide (psi/bar) |
SW-5C22-004-SP | 5,4 g | 5.4 mg-108 mg | 2 | 5–15 | 113.8 | 12.4 | 400/27.5 |
SW-5C22-012-SP | 20 g | 20 mg-0.40 g | 1 | 10–25 | 134.8 | 21.4 | 400/27.5 |
SW-5C22-025-SP | 33 g | 33 mg-0.66 g | 1 | 10–25 | 184 | 21.4 | 400/27.5 |
SW-5C22-040-SP | 48 g | 48 mg-0.96 g | 1 | 15–30 | 184.4 | 26.7 | 400/27.5 |
SW-5C22-080-SP | 105 g | 105 mg-2.1 g | 1 | 20–50 | 257.4 | 31.2 | 350/24.0 |
SW-5C22-120-SP | 155 g | 155 mg-3.1 g | 1 | 30–60 | 261.5 | 38.6 | 300/20.7 |
SW-5C22-220-SP | 300 g | 300 mg-6.0 g | 1 | 40–80 | 223.5 | 61.4 | 300/20.7 |
SW-5C22-330-SP | 420 g | 420 mg-8.4 g | 1 | 40–80 | 280.2 | 61.4 | 250/17.2 |
※ dakọtara na sistemụ chromatography flash niile dị n'ahịa.
Ultra-dị ọcha NH2 oge niile, 40-63 µm, 60 Å
(Ọdịnaya Amino 1.3 mmol/g, ngwụcha ngwụcha, ebe elu 500 m2/g, ike ibu 0.1–2%)
Nọmba ihe | Nha kọlụm | Nha Nlereanya | Nkeji/ Igbe | Ọnụego ebugharị (ml/min) | Ogologo katrij (mm) | NJ cartridge (mm) | Oke. Nrụgide (psi/bar) |
SW-5501-004-IR | 5,9 g | 5.9 mg-118 mg | 2 | 10–20 | 113.8 | 12.4 | 400/27.5 |
SW-5501-012-IR | 23 g | 23 mg-0.46 g | 1 | 15–30 | 134.8 | 21.4 | 400/27.5 |
SW-5501-025-IR | 38 g | 38 mg-0.76 g | 1 | 15–30 | 184 | 21.4 | 400/27.5 |
SW-5501-040-IR | 55 g | 55 mg-1.1 g | 1 | 20–40 | 184.4 | 26.7 | 400/27.5 |
SW-5501-080-IR | 122 g | 122 mg-2.5 g | 1 | 30–60 | 257.4 | 31.2 | 350/24.0 |
SW-5501-120-IR | 180 g | 180 mg-3.6 g | 1 | 40–80 | 261.5 | 38.6 | 300/20.7 |
SW-5501-220-IR | 340 g | 340 mg-6.8 g | 1 | 50–100 | 223.5 | 61.4 | 300/20.7 |
SW-5501-330-IR | 475 g | 475 mg-9.5 g | 1 | 50–100 | 280.2 | 61.4 | 250/17.2 |
※ dakọtara na sistemụ chromatography flash niile dị n'ahịa.
Ultra-ọcha na-adịghị agafe agafe SAX, 40-63 µm, 60 Å
(ihe dị na carbon 8%, ebe elu 500 m2/ g, ikike mgbanwe ion ≤ 0.26 meq/g)
Nọmba ihe | Nha kọlụm | Nha Nlereanya | Nkeji/ Igbe | Ọnụego ebugharị (ml/min) | Ogologo katrij (mm) | NJ cartridge (mm) | Oke. Nrụgide (psi/bar) |
SW-5001-004-IR | 5,9 g | ≤ 1.53 meq | 2 | 10–20 | 113.8 | 12.4 | 400/27.5 |
SW-5001-012-IR | 23 g | ≤ 5.98 meq | 1 | 15–30 | 134.8 | 21.4 | 400/27.5 |
SW-5001-025-IR | 38 g | 9.88mq | 1 | 15–30 | 184 | 21.4 | 400/27.5 |
SW-5001-040-IR | 55 g | ≤ 14.30 meq | 1 | 20–40 | 184.4 | 26.7 | 400/27.5 |
SW-5001-080-IR | 122 g | ≤ 31.72 meq | 1 | 30–60 | 257.4 | 31.2 | 350/24.0 |
SW-5001-120-IR | 180 g | ≤ 46.80 meq | 1 | 40–80 | 261.5 | 38.6 | 300/20.7 |
SW-5001-220-IR | 340 g | ≤ 88.40 meq | 1 | 50–100 | 223.5 | 61.4 | 300/20.7 |
SW-5001-330-IR | 475 g | ≤ 123.50 meq | 1 | 50–100 | 280.2 | 61.4 | 250/17.2 |
※ dakọtara na sistemụ chromatography flash niile dị n'ahịa.
Ultra-dị ọcha SCX oge niile, 40-63 µm, 60 Å
(ihe dị ka carbon 10%, ebe elu 500 m2/ g, ikike mgbanwe ion ≤ 0.34 meq/g)
Nọmba ihe | Nha kọlụm | Nha Nlereanya | Nkeji/ Igbe | Ọnụego ebugharị (ml/min) | Ogologo katrij (mm) | NJ cartridge (mm) | Oke. Nrụgide (psi/bar) |
SW-5701-004-IR | 5,9 g | ≤ 2.01 meq | 2 | 10–20 | 113.8 | 12.4 | 400/27.5 |
SW-5701-012-IR | 23 g | ≤7.82mq | 1 | 15–30 | 134.8 | 21.4 | 400/27.5 |
SW-5701-025-IR | 38 g | ≤ 12.92 meq | 1 | 15–30 | 184 | 21.4 | 400/27.5 |
SW-5701-040-IR | 55 g | ≤ 18.70 meq | 1 | 20–40 | 184.4 | 26.7 | 400/27.5 |
SW-5701-080-IR | 122 g | ≤ 41.48 meq | 1 | 30–60 | 257.4 | 31.2 | 350/24.0 |
SW-5701-120-IR | 180 g | ≤ 61.20 meq | 1 | 40–80 | 261.5 | 38.6 | 300/20.7 |
SW-5701-220-IR | 340 g | ≤ 115.60 meq | 1 | 50–100 | 223.5 | 61.4 | 300/20.7 |
SW-5701-330-IR | 475 g | ≤ 161.50 meq | 1 | 50–100 | 280.2 | 61.4 | 250/17.2 |
※ dakọtara na sistemụ chromatography flash niile dị n'ahịa.
- AN001-Nchacha nke ngwakọta Hydrophilic site na SepaFlash™ HILIC Cartridges
- AN003- Ngwa nke SepaFlash ™ HILIC Cartridges n'ime ịdị ọcha nke Intermediates Synthetic
- AN004- Nhọrọ nke usoro mkpanaaka na Chromatography nke agbaghachi azụ
- AN008-Nchọgharị nke usoro nkwadebe n'ịkwalite site na SepaFlash™ kọlụm ntughari-isi.
- AN010- Ngwa nke SepaFlash ™ katrijị agbagharị agbagharị maka ihe nlele polar na obere soluble
- AN014_Mmelite nke mkpebi site na kọlụm stacking na ngwa ya
- AN015_Hydrophobic Usoro ndakpọ, kọlụm Chromatography Na-atụgharị AQ
- AN016_ Ngwa nke SepaFlash™ Strong Cation Exchange Kọlụm n'ime ọcha nke ogige Alkaline
- AN017-Nhicha nke Taxus Extract site na igwe SepaBean
- AN018_Ngwa nke kọlụm C18AQ na nhicha nke peptides siri ike.
- AN019_Nsacha nke adịghị ọcha nke ukwuu na ọgwụ nje sitere na kọlụm C18AQ
- AN020- Ngwa nke SepaFlash ™ Strong Anion Exchange Chromatography kọlụm n'ime ọcha nke ngwakọta acidic.
- AN024_Ngwa nke chromatography orthogonal maka sachapụ nke etiti ọgwụ ọgwụ sịntetị.
- AN026_Ngwa nke SepaFlash HILIC ARG Cartridge maka sachapụ ogige Thiazide siri ike.
- AN027_SepaFlash™ HILIC ARG katrij na ngwa ya na nchacha nke Oligosaccharide
- AN028_Ntuziaka onye ọrụ maka iji, ihicha na nchekwa nke SepaFlash™ agbakwunyere usoro Flash kọlụm
- AN029_SepaFlash™ C18AQ Cartridge na ngwa ya na nchacha nke ihe glutamine.
- AN033_SepaFlash™ HILIC ARG Cartridge na ngwa ya na nchacha nke Amino Acid
- AN036_SepaFlash™ C18AQ Cartridge na ngwa ya na Sample Desalting
- AN-SS-003 Facile dị ọcha nke nnukwu carbohydrates steekị bicyclic ahọpụtara site na igwe SepaBean™
- AN-SS-006 Nkewa nke CBD na THC site na SepaFlash ™ Spherical C18 Ogidi
- SepaFlash kọlụm katalọgụ EN