ibe_banner

SepaBean™ igwe T

SepaBean™ igwe T

Nkọwa dị mkpirikpi:

● Nlereanya dị ọnụ ahịa nwere atụmatụ niile nke ngwanrọ njikwa SepaBean™.

● ọnụọgụ abụọ gradient na ngwakọta ọ bụla nke ihe mgbaze abụọ.

● Nhọrọ ELSD iji kpuchie ụdị nlele ọzọ.


Nkọwa ngwaahịa

Ngwa

Vidiyo

katalọgụ

Ngwa ngwaahịa

Nlereanya SepaBean™ igwe T
Ihe Mba. SPBT02000200-1 SPBT02000200-2
Nchọpụta DAD agbanwe UV (200 - 400 nm) DAD agbanwe UV (200 - 400 nm) + Vis (400 - 800 nm)
Oke ọsọ 1-200 ml / nkeji
Nrụgide kacha 200 psi (13.8 mmanya)
Sistemụ mgbapụta Ezigbo ezi, mgbapụta seramiiki na-enweghị mmezi
Gradients ọnụọgụ abụọ ihe mgbaze anọ nwere ngwakọta ọ bụla nke ihe mgbaze abụọ
Ikike ibu ihe nlele 10 mg - 33 g
Nha kọlụm 4 g - 330 g, ruo 3 n'arọ na nkwụnye
Ụdị gradient isocratic, linear, nzọụkwụ
Ogologo ụzọ anya Flowcell 0.3 mm (nke ndabara); 2.4 mm (nhọrọ).
Ngosipụta Spectral otu / dual / niile-wavelengths
Usoro ntinye ihe nlele ibu aka
Usoro nchịkọta irighiri ihe niile, igbu oge, ọnụ ụzọ, mkpọda, oge
Onye nchịkọta irighiri ihe ọkọlọtọ: tubes (13 mm, 15 mm, 16 mm, 18 mm, 25 mm);
  Nhọrọ: Kalama square francth (250 ml, 500 ml) ma ọ bụ nnukwu karama mkpokọta;
  Akpa mkpokọta nwere ike ịhazi ya
Ngwa njikwa arụ ọrụ ikuku site na ngwaọrụ mkpanaka*
Asambodo CE, TUV
* iPad

Akụkụ nke Flash Chromatography Sistemu SepaBean™ Machine T

Ịrụ ọrụ ikuku site na ngwaọrụ mkpanaka
Usoro njikwa ikuku na-agbanwe agbanwe dabara adaba maka nnwale nkewa nke achọrọ ka echebe ya pụọ ​​na ọkụ ma ọ bụ tinye ya n'ebe dịpụrụ adịpụ.

Iweghachite ọdịda ike
Ọrụ mgbanyụ ọkụ arụnyere arụnyere na ngwanrọ na-ebelata mfu nke ọdịda ike mberede kpatara.

Nkwanye usoro nkewa
Akụrụngwa nwere nchekwa data usoro nkewa arụnyere na-akwado na-akpaghị aka na usoro nkewa kacha dabara adaba na isi ozi onye ọrụ tinyere, si otú a na-emeziwanye arụmọrụ ọrụ.

Onye nchịkọta irighiri
Igwe mmiri tube nwere ihe ngosi LCD na-enyere ndị ọrụ aka iji ngwa ngwa soro tubes nwere ụmụ irighiri ihe anakọtara.

Ịkekọrịta data netwọk mpaghara
Ngwá ọrụ dị iche iche nwere ike ịmepụta netwọk mpaghara iji kwado nkesa data dị n'ime yana njikarịcha akụrụngwa na ụlọ nyocha.

21-CFR Nkebi 11 nnabata
Akụrụngwa njikwa na-akwado ihe FDA chọrọ maka nchekwa sistemu (21-CFR Nkebi 11), na-eme ka akụrụngwa dabara adaba maka ụlọ ọrụ R&D ọgwụ na ụlọ nyocha.

Usoro nchacha nke ọma na-eme ka ọ dị mfe
Sistemụ smart flash chromatography nke SepaBean™ igwe T nke Santai Teknụzụ bidoro nwere atụmatụ etinyere n'ime usoro nkewa. Ọbụna ndị mbido ma ọ bụ ndị na-arụ ọrụ chromatography na-abụghị ndị ọkachamara nwere ike mezue ọrụ nchacha ahụ n'ụzọ dị mfe.

Ọcha smart na ịdị mfe "Metụ & Gaa".
A na-arụ ọrụ SepaBean ™ T site na ekwentị mkpanaaka, yana UI nwere akara ngosi, ọ dị mfe maka ndị mbido na ndị na-abụghị ndị ọkachamara iji mezue nkewa oge niile, mana ọ dịkwa ọkaibe zuru oke maka ọkachamara ma ọ bụ guru imezu ma ọ bụ kwalite nkewa dị mgbagwoju anya.

Ebe nchekwa data usoro arụnyere n'ime - Ejidere ihe ọmụma
Ndị na-eme nchọpụta gburugburu ụwa na-etinye ọtụtụ ihe onwunwe iji mepụta ụzọ nke ikewa na sachapụ ngwakọta ngwakọta, ma ọ bụ ngwakọta synthesized, ma ọ bụ ihe ndị sitere na ngwaahịa sitere n'okike, a na-echekwa ụzọ ndị a bara uru n'otu ebe, dịpụrụ adịpụ, kewapụ, wee ghọọ "agwaetiti ozi" n'elu. oge. N'adịghị ka ngwa ọkụ ọkụ ọdịnala, SepaBean™ igwe T na-eji nchekwa data na teknụzụ mgbakọ na-ekesa iji jide ma kesaa usoro ndị a n'ofe netwọk nhazi echekwara:
● Patented SepaBean™ igwe T arụnyere n'ime nchekwa data mmekọrịta iji chekwaa ụzọ nkewa, ndị nchọpụta nwere ike jụọ ajụjụ dị adị ma ọ bụ melite usoro nkewa ọhụrụ naanị site na iji aha aha, nhazi ma ọ bụ koodu ọrụ.
● SepaBean ™ igwe T bụ netwọk dị njikere, ọtụtụ ngwá ọrụ n'ime ụlọ ọrụ nwere ike ịmepụta ọwa nkeonwe, ka e wee kesaa usoro nkewa n'ofe nzukọ ahụ dum, ndị nchọpụta ikike nwere ike ịnweta ma mee usoro ndị a ozugbo na-enweghị ịmaliteghachi usoro ahụ.
● SepaBean™ igwe T nwere ike ịchọpụta na jikọọ na ngwa ndị ọgbọ na-akpaghị aka, ozugbo ejikọtara ọtụtụ ngwa, data na-ejikọta ya na-akpaghị aka, ndị nchọpụta nwere ike ịnweta usoro ha na ngwa ọ bụla ejikọrọ na ebe ọ bụla.


  • Nke gara aga:
  • Osote:

    • AN011-Nweta nghọta n'ime igwe SepaBean ™ ya na onye injinia: onye nchọpụta ọkụ na-ekpochapụ ọkụ.
      AN011-Nweta nghọta n'ime igwe SepaBean ™ ya na onye injinia: onye nchọpụta ọkụ na-ekpochapụ ọkụ.
    • AN020- Ngwa nke SepaFlash ™ Strong Anion Exchange Chromatography kọlụm n'ime ọcha nke ngwakọta acidic.
      AN020- Ngwa nke SepaFlash ™ Strong Anion Exchange Chromatography kọlụm n'ime ọcha nke ngwakọta acidic.
    • AN023_SepaFlash™ Ruby Series High Resolution Normal Phase Silicone Column Reeji na Ntuziaka Nchekwa
      AN023_SepaFlash™ Ruby Series High Resolution Normal Phase Silicone Column Reeji na Ntuziaka Nchekwa
    • AN024_Ngwa ​​nke chromatography orthogonal maka sachapụ nke etiti ọgwụ ọgwụ sịntetị.
      AN024_Ngwa ​​nke chromatography orthogonal maka sachapụ nke etiti ọgwụ ọgwụ sịntetị.
    • AN025_Nweta nghọta n'ime igwe SepaBean ™ nwere injinia-pumps na valvụ agwakọta
      AN025_Nweta nghọta n'ime igwe SepaBean ™ nwere injinia-pumps na valvụ agwakọta
    • AN026_Ngwa ​​nke SepaFlash HILIC ARG Cartridge maka sachapụ ogige Thiazide siri ike.
      AN026_Ngwa ​​nke SepaFlash HILIC ARG Cartridge maka sachapụ ogige Thiazide siri ike.
    • AN027_SepaFlash™ HILIC ARG katrij na ngwa ya na nchacha nke Oligosaccharide
      AN027_SepaFlash™ HILIC ARG katrij na ngwa ya na nchacha nke Oligosaccharide
    • AN029_SepaFlash™ C18AQ Cartridge na ngwa ya na nchacha nke ihe glutamine.
      AN029_SepaFlash™ C18AQ Cartridge na ngwa ya na nchacha nke ihe glutamine.
    • AN030_Nchacha nke okpueze Ether Sample site na Quaternary Solvent Flash Chromatography Sistemu
      AN030_Nchacha nke okpueze Ether Sample site na Quaternary Solvent Flash Chromatography Sistemu
    • AN032_Nhicha nke Diastereomers site na SepaFlash™ C18 Reverser Phase Cartridge
      AN032_Nhicha nke Diastereomers site na SepaFlash™ C18 Reverser Phase Cartridge
    • AN033_SepaFlash™ HILIC ARG Cartridge na ngwa ya na nchacha nke Amino Acid
      AN033_SepaFlash™ HILIC ARG Cartridge na ngwa ya na nchacha nke Amino Acid
    • AN034_Nweta nghọta n'ime igwe SepaBean™ ya na Injinia Mmetụta nke ihe nchọpụta na-efegharị cell na Flash Chromatography
      AN034_Nweta nghọta n'ime igwe SepaBean™ ya na Injinia Mmetụta nke ihe nchọpụta na-efegharị cell na Flash Chromatography
    • AN035_ Ngwa nke igwe SepaBean ™ Ejiri ELSD maka nhicha nke PEG
      AN035_ Ngwa nke igwe SepaBean ™ Ejiri ELSD maka nhicha nke PEG
    • AN-SS-003 Facile dị ọcha nke nnukwu carbohydrates steekị bicyclic ahọpụtara site na igwe SepaBean™
      AN-SS-003 Facile dị ọcha nke nnukwu carbohydrates steekị bicyclic ahọpụtara site na igwe SepaBean™
    • AN-SS-005 Ụzọ Mwepụta Mwepụta maka Cannabidiolic Acid sitere na Cannabis sativa L. Iji SepaBean™ Flash Chromatography Systems
      AN-SS-005 Ụzọ Mwepụta Mwepụta maka Cannabidiolic Acid sitere na Cannabis sativa L. Iji SepaBean™ Flash Chromatography Systems
    • Igwe SepaBean T ntuziaka ọrụ
    • Ntọala ngwaọrụ SepaBean – Tube Rack Calibration
    • Nlekọta SepaBean - Nozzles dị ọcha
    • Nlekọta SepaBean - Nchacha ikuku
    • Mmezi SepaBean – Ntugharị mgbapụta mgbapụta
    • SepaBean Machine katalọgụ EN
      SepaBean Machine katalọgụ EN
    Dee ozi gị ebe a ziga anyị ya