HP series flash kab yog spin-welded thiab tso cai rau siab siab txog li 400 psi. Muaj cov adapter pab txhawb kev sib raug zoo nrog txhua qhov system flash ntawm kev ua lag luam. Cov koob no muab Luer-Lok hauv thiab Luer-Lok tawm yooj yim rau kev yooj yim kem stacking. Thaum pre-packed nrog high-efficiency silica gel (tsis xwm yeem, 25-40 μm, 60 Å; kheej kheej, 20-45 μm, 70 Å), cov koob no nthuav tawm qhov kev daws teeb meem zoo tshaj li cov khoom siv flash.
※ Xaiv dawb silica los yog spherical silica raws li koj tus kheej nyiam
※ Kev daws teeb meem zoo dua qub thiab muaj peev xwm thauj khoom ntau dua
※ Spherical silica muab kev ua tau zoo dua yam tsis tau ua kom lub cev muaj zog
Rau spherical silica gel, nruj zoo tswj los ntawm raw khoom mus rau cov khoom tiav kom ntseeg tau siab ntau-rau-ntau reproducibility thiab nruj tswj specifications.
※ Kev sib raug zoo, kev ntseeg siab, kev tsim tawm
※ Tsis muaj kab mob, txo qis qis
※ Superior daws teeb meem
※ Symmetrical peaks tsis muaj tailing
※ Ntau cov qauv thauj khoom muaj peev xwm
High-efficiency silica, 25-40 µm, 60 Å(qhov chaw thaj tsam 500 m2/g, pH 6.5-7.5, loading peev 0.1-15%)
Yam khoom naj npawb | Kem Loj | Qauv Loj (g) | Tus nqi ntws (mL / min) | Cartridge Ntev (cm) | Cartridge ID (hli) | Max. Siab (psi / bar) | Quantity per Box | |
Me me | Loj | |||||||
SWB-5102-004 | 4g | 4 mg-0.6g | 15–30 : kuv | 113.8 ib | 12.4 | 400/27.5 | 24 | 120 |
SWB-5102-012 | 12g ua | 12 mg-1.8g | 25–50 : kuv | 134.8 ib | 21.4 ib | 400/27.5 | 24 | 108 |
SWB-5102-025 | 25g ua | 25 mg-3.8g | 25–50 : kuv | 184 | 21.4 ib | 400/27.5 | 18 | 72 |
SWB-5102-040 | 40g ua | 40 mg-6.0g | 30–60 : kuv | 184.4 ib | 26.7 ib | 400/27.5 | 12 | 48 |
NWS-5102-080 | 80g ua | 80 mg-12 g | 40–80 : kuv | 257.4 ib | 31.2 ib | 350/24.0 Nws | 10 | 20 |
SWB-5102-120 | 120 g | 120 mg-18g | 45–90 : kuv | 261.5 ib | 38.6 ib | 300/20.7 | 8 | 16 |
SWB-5102-220 | 220g ua | 220 mg-33 g | 60–120 : kuv | 223.5 Nws | 61.4 ib | 300/20.7 | 4 | 8 |
SWB-5102-330 | 330g ua | 330 mg-50 g | 60–120 : kuv | 280.2 ib | 61.4 ib | 250/17.2 | 3 | 6 |
SWB-5102-800 | 800 g | 800 mg-120 g | 50-100 | 382.9 ib | 78.2 ib | 100/6.9 | 3 | - |
SWB-5102-1600 | 1600 g | 1.6g-240g | 50-100 | 432.4 ib | 103.8 ib | 100/6.9 | 2 | - |
SWB-5102-3000 | 3kg ua | 3g-450g | 50-100 | 509.5 ib | 127.5 ib | 100/6.9 | 1 | - |
SWB-5102-5000 | 5kg ua | 5g-750g | 50-100 | 770 ib | 127.5 ib | 100/6.9 | 1 | - |
SW-5102-010K | 10kg ua | Yog '- 10-1.5 kg | 50-100 | 850 | 172.5 ib | 100/6.9 | 1 | - |
※ Tau tshaj txhua lub tshuab flash chromatography ntawm lub khw.
Kev lim dej ntawm cov tebchaw uas nyuaj rau kev sib cais los ntawm flash chromatography (ΔRf ≤ 0.2 nruab nrab ntawm qhov chaw ntawm TLC) feem ntau ua rau cov kauj ruam ntxiv xws li kev ua kom huv tom qab los ntawm kev npaj ntsuas HPLC. Nws muaj peev xwm txo tau cov hauj lwm ntxiv uas yuav tsum tau ua kom huv si los ntawm kev yooj yim stacking ob peb prepacked SepaFlash ™ kab kawg mus rau qhov kawg ntawm lub flash chromatography system.
Hauv cov kua chromatography, cov tshuaj lom neeg raug cais raws li lawv qhov sib txawv ntawm qhov nrawm thaum lawv txav mus los ntawm kab. Nce kab ntev tuaj yeem txhim kho kev daws teeb meem. Los ntawm stacking kab xaus mus rau qhov kawg ntawm qhov ntev mus rau txoj kab uas hla (L mus rau D) piv yog nce kom tsis muaj kev hloov pauv loj rau kev tshaj tawm thiab cov kuab tshuaj uas tsim nyog. Feem ntau qhov no nce L rau D yog txaus los muab kev sib cais ntawm cov sib tov nyuaj vim yog lub sij hawm kaw cov khoom sib txuas uas tsis tau txais ntawm ib kab. Cov ntaub ntawv qhia txog kev sib raug zoo ntawm kev daws teeb meem thiab tag nrho cov kab ntev.
UltraPure kheej kheej silica, 40-75 µm, 70 Å(qhov chaw thaj tsam 500 m2/g, pH 6.0-8.0, loading peev 0.1-10%)
Yam khoom naj npawb | Kem Loj | Qauv Loj (g) | Tus nqi ntws (mL / min) | Cartridge Ntev (cm) | Cartridge ID (hli) | Max. Siab (psi / bar) | Quantity per Box | |
Me me | Loj | |||||||
SW-2101-004-SP | 4g | 4 mg-0.4g | 15–40 : kuv | 113.8 ib | 12.4 | 400/27.5 | 24 | 120 |
SW-2101-012-SP | 12g ua | 12 mg – 1.2 g | 30–60 : kuv | 134.8 ib | 21.4 ib | 400/27.5 | 24 | 108 |
SW-2101-025-SP | 25g ua | 25 mg – 2.5 g | 30–60 : kuv | 184 | 21.4 ib | 400/27.5 | 18 | 72 |
SW-2101-040-SP | 40g ua | 40 mg-4.0g | 40–70 : kuv | 184.4 ib | 26.7 ib | 400/27.5 | 12 | 48 |
SW-2101-080-SP | 80g ua | 80mg-8.0g | 50–100 | 257.4 ib | 31.2 ib | 350/24.0 Nws | 10 | 20 |
SW-2101-120-SP | 120 g | 120 mg-12 g | 60–150 : kuv | 261.5 ib | 38.6 ib | 300/20.7 | 8 | 16 |
SW-2101-220-SP | 220g ua | 220 mg-22 g | 80–220 : kuv | 223.5 Nws | 61.4 ib | 300/20.7 | 4 | 8 |
SW-2101-330-SP | 330g ua | 330mg-33g | 80–220 : kuv | 280.2 ib | 61.4 ib | 250/17.2 | 3 | 6 |
SW-2101-800-SP | 800 g | 800mg-80g | 50-100 | 382.9 ib | 78.2 ib | 100/6.9 | 3 | - |
SWB-2101-1600-SP | 1600 g | 1.6-160 g yog ' | 50-100 | 432.4 ib | 103.8 ib | 100/6.9 | 2 | - |
SW-2101-3000-SP | 3kg ua | 3-300 g yog ' | 50-100 | 509.5 ib | 127.5 ib | 100/6.9 | 1 | - |
SW-2101-5000-SP | 5kg ua | 5-500 g yog ' | 50-100 | 770 ib | 127.5 ib | 100/6.9 | 1 | - |
SW-2101-010K-SP | 10kg ua | Yog '- 10 g | 50-100 | 850 | 172.5 ib | 100/6.9 | 1 | - |
※ Tau tshaj txhua lub tshuab flash chromatography ntawm lub khw.
High-efficiency spherical silica, 20-45 µm, 70 Å(qhov chaw thaj tsam 500 m2/g, pH 6.0-8.0, loading peev 0.1-15%)
Yam khoom naj npawb | Kem Loj | Qauv Loj (g) | Tus nqi ntws (mL / min) | Cartridge Ntev (cm) | Cartridge ID (hli) | Max. Siab (psi / bar) | Quantity per Box | |
Me me | Loj | |||||||
SW-2102-004-SP | 4g | 4 mg-0.6g | 15–30 : kuv | 113.8 ib | 12.4 | 400/27.5 | 24 | 120 |
SW-2102-012-SP | 12g ua | 12 mg-1.8g | 25-50 | 134.8 ib | 21.4 ib | 400/27.5 | 24 | 108 |
SW-2102-025-SP | 25g ua | 25 mg-3.8g | 25-50 | 184 | 21.4 ib | 400/27.5 | 18 | 72 |
SW-2102-040-SP | 40g ua | 40 mg-6.0g | 30–60 : kuv | 184.4 ib | 26.7 ib | 400/27.5 | 12 | 48 |
SW-2102-080-SP | 80g ua | 80 mg-12 g | 40–80 : kuv | 257.4 ib | 31.2 ib | 350/24.0 Nws | 10 | 20 |
SWB-2102-120-SP | 120 g | 120 mg-18g | 45–90 : kuv | 261.5 ib | 38.6 ib | 300/20.7 | 8 | 16 |
SW-2102-220-SP | 220g ua | 220 mg-33 g | 60–120 : kuv | 223.5 Nws | 61.4 ib | 300/20.7 | 4 | 8 |
SW-2102-330-SP | 330g ua | 330 mg-50 g | 60–120 : kuv | 280.2 ib | 61.4 ib | 250/17.2 | 3 | 6 |
SW-2102-800-SP | 800 g | 800 mg-120 g | 50-100 | 382.9 ib | 78.2 ib | 100/6.9 | 3 | - |
SWB-2102-1600-SP | 1600 g | 1.6g-240g | 50-100 | 432.4 ib | 103.8 ib | 100/6.9 | 2 | - |
SW-2102-3000-SP | 3kg ua | 3g-450g | 50-100 | 509.5 ib | 127.5 ib | 100/6.9 | 1 | - |
SW-2102-5000-SP | 5kg ua | 5g-750g | 50-100 | 770 ib | 127.5 ib | 100/6.9 | 1 | - |
SW-2102-010K-SP | 10kg ua | Yog '- 10-1.5 kg | 50-100 | 850 | 172.5 ib | 100/6.9 | 1 | - |
※ Tau tshaj txhua lub tshuab flash chromatography ntawm lub khw.
Muaj peev xwm spherical silica, 50 μm, 54 Å(nto cheeb tsam 700 m2 / g, pH 6.0-8.0, loading peev 0.1-30%)
Yam khoom naj npawb | Kem Loj | Qauv Loj (g) | Tus nqi ntws (mL / min) | Cartridge Ntev (cm) | Cartridge ID (hli) | Max. Siab (psi / bar) | Quantity per Box | |
Me me | Loj | |||||||
SW-2101-004-SP(H) Tus Qauv Zauv | 4g | 4 mg-1.2g | 15–30 : kuv | 113.8 ib | 12.4 | 400/27.5 | 24 | 120 |
SW-2101-012-SP(H) Tus Qauv Zauv | 12g ua | 12 mg-3.6g | 25-50 | 134.8 ib | 21.4 ib | 400/27.5 | 24 | 108 |
SW-2101-025-SP(H) Tus Qauv Zauv | 25g ua | 25 mg-7.5g | 25-50 | 184 | 21.4 ib | 400/27.5 | 18 | 72 |
SW-2101-040-SP(H) Tus Qauv Zauv | 40g ua | 40 mg-12 g | 30-60 | 184.4 ib | 26.7 ib | 400/27.5 | 12 | 48 |
SW-2101-080-SP(H) Tus Qauv Zauv | 80g ua | 80 mg-24 g | 40-80 : kuv | 257.4 ib | 31.2 ib | 350/24.0 Nws | 10 | 20 |
SW-2101-120-SP(H) Tus Qauv Zauv | 120 g | 120 mg-36 g | 45-90 : kuv | 261.5 ib | 38.6 ib | 300/20.7 | 8 | 16 |
SW-2101-220-SP(H) Tus Qauv Zauv | 220g ua | 220 mg – 66 g | 60-120 | 223.5 Nws | 61.4 ib | 300/20.7 | 4 | 8 |
SW-2101-330-SP(H) Tus Qauv Zauv | 330g ua | 330mg-99g | 60-120 | 280.2 ib | 61.4 ib | 250/17.2 | 3 | 6 |
SW-2101-800-SP(H) Tus Qauv Zauv | 800 g | 800 mg-240 g | 50-100 | 382.9 ib | 78.2 ib | 100/6.9 | 3 | - |
SW-2101-1600-SP(H) Tus Qauv Zauv | 1600 g | 1.6g-480g | 50-100 | 432.4 ib | 103.8 ib | 100/6.9 | 2 | - |
SW-2101-3000-SP(H) Tus Qauv Zauv | 3kg ua | 3g-900g ib | 50-100 | 509.5 ib | 127.5 ib | 100/6.9 | 1 | - |
SW-2101-5000-SP(H) Tus Qauv Zauv | 5kg ua | Yog '- 1.5 kg | 50-100 | 770 ib | 127.5 ib | 100/6.9 | 1 | - |
SW-2101-010K-SP(H) Tus Qauv Zauv | 10kg ua | Yog '- 10-3 kg | 50-100 | 850 | 172.5 ib | 100/6.9 | 1 | - |
※ Tau tshaj txhua lub tshuab flash chromatography ntawm lub khw.
High-capacity spherical silica, 25 µm, 50 Å(qhov chaw thaj tsam 700 m2/g, pH 5.0-8.0, loading peev 0.1-30%)
Yam khoom naj npawb | Kem Loj | Qauv Loj (g) | Tus nqi ntws (mL / min) | Cartridge Ntev (cm) | Cartridge ID (hli) | Max. Siab (psi / bar) | Quantity per Box | |
Me me | Loj | |||||||
SW-2102-004-SP(H) Tus Qauv Zauv | 4g | 4 mg-1.2g | 15–30 : kuv | 113.8 ib | 12.4 | 400/27.5 | 24 | 120 |
SW-2102-012-SP(H) Tus Qauv Zauv | 12g ua | 12 mg-3.6g | 25-50 | 134.8 ib | 21.4 ib | 400/27.5 | 24 | 108 |
SW-2102-025-SP(H) Tus Qauv Zauv | 25g ua | 25 mg-7.5g | 25-50 | 184 | 21.4 ib | 400/27.5 | 18 | 72 |
SW-2102-040-SP(H) Tus Qauv Zauv | 40g ua | 40 mg-12 g | 30-60 | 184.4 ib | 26.7 ib | 400/27.5 | 12 | 48 |
SW-2102-080-SP(H) Tus Qauv Zauv | 80g ua | 80 mg-24 g | 40-80 : kuv | 257.4 ib | 31.2 ib | 350/24.0 Nws | 10 | 20 |
SW-2102-120-SP(H) Tus Qauv Zauv | 120 g | 120 mg-36 g | 45-90 : kuv | 261.5 ib | 38.6 ib | 300/20.7 | 8 | 16 |
SW-2102-220-SP(H) Tus Qauv Zauv | 220g ua | 220 mg – 66 g | 60-120 | 223.5 Nws | 61.4 ib | 300/20.7 | 4 | 8 |
SW-2102-330-SP(H) Tus Qauv Zauv | 330g ua | 330mg-99g | 60-120 | 280.2 ib | 61.4 ib | 250/17.2 | 3 | 6 |
SW-2102-800-SP(H) Tus Qauv Zauv | 800 g | 800 mg-240 g | 50-100 | 382.9 ib | 78.2 ib | 100/6.9 | 3 | - |
SW-2102-1600-SP(H) Tus Qauv Zauv | 1600 g | 1.6g-480g | 50-100 | 432.4 ib | 103.8 ib | 100/6.9 | 2 | - |
SW-2102-3000-SP(H) Tus Qauv Zauv | 3kg ua | 3g-900g ib | 50-100 | 509.5 ib | 127.5 ib | 100/6.9 | 1 | - |
SW-2102-5000-SP(H) Tus Qauv Zauv | 5kg ua | Yog '- 1.5 kg | 50-100 | 770 ib | 127.5 ib | 100/6.9 | 1 | - |
SW-2102-010K-SP(H) Tus Qauv Zauv | 10kg ua | Yog '- 10-3 kg | 50-100 | 850 | 172.5 ib | 100/6.9 | 1 | - |
※ Tau tshaj txhua lub tshuab flash chromatography ntawm lub khw.
High-capacity spherical silica, 15 µm, 50 Å(qhov chaw thaj tsam 700 m2/g, pH 5.0-8.0, loading peev 0.1-30%)
Yam khoom naj npawb | Kem Loj | Qauv Loj (g) | Tus nqi ntws (mL / min) | Cartridge Ntev (cm) | Cartridge ID (hli) | Max. Siab (psi / bar) | Quantity per Box | |
Me me | Loj | |||||||
SW-2103-004-SP(H) Tus Qauv Zauv | 4 g ib | 4 mg – 1.2 g | 10–15 | 113.8 ib | 12.4 | 400/27.5 | 24 | 120 |
SW-2103-012-SP(H) Tus Qauv Zauv | 12g ua | 12 mg-3.6 g | 15–20 | 134.8 ib | 21.4 ib | 400/27.5 | 24 | 108 |
SW-2103-025-SP(H) Tus Qauv Zauv | 25g ua | 25 mg-7.5 g | 15–20 | 184 | 21.4 ib | 400/27.5 | 18 | 72 |
SW-2103-040-SP(H) Tus Qauv Zauv | 40g ua | 40 mg-12 g | 20–30 : kuv | 184.4 ib | 26.7 ib | 400/27.5 | 12 | 48 |
SW-2103-080-SP(H) Tus Qauv Zauv | 80g ua | 80 mg-24 g | 30–40 : kuv | 257.4 ib | 31.2 ib | 350/24.0 Nws | 10 | 20 |
SW-2103-120-SP(H) Tus Qauv Zauv | 120 g | 120 mg-36 g | 35–45 : kuv | 261.5 ib | 38.6 ib | 300/20.7 | 8 | 16 |
SW-2103-220-SP(H) Tus Qauv Zauv | 22 0g | 220 mg-66 g | 50–65 : kuv | 223.5 Nws | 61.4 ib | 300/20.7 | 4 | 8 |
SW-2103-330-SP(H) Tus Qauv Zauv | 330g ua | 330 mg-99 g | 50–65 : kuv | 280.2 ib | 61.4 ib | 250/17.2 | 3 | 6 |
※ Tau tshaj txhua lub tshuab flash chromatography ntawm lub khw.
Ob chav Loading Peev Xwm ntawm SepaFlash ™ Cartridges ua ntej ntim nrog lub peev xwm siab silica gel (700 m2/ g rau 50 Å pore loj) xa cov kev ua kom huv siab tshaj plaws. Lub siab muaj peev xwm 25 µm lossis 15 µm spherical silica muaj 40% ntau dua qhov chaw, ob npaug ntawm lub peev xwm thauj khoom ntawm thaj chaw silica. Santai tau ntsuas qhov kev ua tau zoo ntawm SepaFlash ™ kab piv rau ob lub npe nrov. Cov txiaj ntsig tau pom tias SepaFlash ™ ua tau zoo dua cov neeg sib tw.
- AN006-Kev Purification ntawm Me Molecular Peptide los ntawm SepaFlash™ HP Bio Series Flash Cartridge
- AN009-Kev Purification ntawm Porphyrins los ntawm SepaBean ™ tshuab
- AN012-Daim ntawv thov ntawm SepaFlash ™ Cartridges hauv Kev Ua Kom Huv Ntawm Diazo Compounds
- AN021_Kev siv cov kab hauv kev ua kom huv ntawm Organic Optoelectronic Materials
- AN022_Higher Sample Loading Capacity, Zoo dua - Daim Ntawv Thov ntawm SepaFlash™ Ruby High Resolution Cartridges
- AN023_SepaFlash™ Ruby Series High Resolution Li qub Phase Silicone Kem Reuse thiab Cia Qhia
- AN-SS-007-Reusable Santai SepaFlash™ Ruby Series Kem Khiav Kev Sib Nrauj Txog 100 zaug