factory low price Irregular Silica Flash Column - SepaFlash™ HP Series – Santai

factory low price Irregular Silica Flash Column - SepaFlash™ HP Series – Santai

Short Description:


Product Detail

Application

Video

catalogue

Related Video

Feedback (2)

We depend on sturdy technical force and continually create sophisticated technologies to meet the demand of Solid Loading Flash Cartridge, Solid Loading Flash Cartridge, Related Brand Macherey-Nagel, Let's cooperate hand in hand to jointly make a beautiful future. We sincerely welcome you to visit our company or contact us for cooperation!
factory low price Irregular Silica Flash Column - SepaFlash™ HP Series – Santai Detail:

HP series flash columns are spin-welded and allow for higher pressure of up to 400 psi. Available adapter facilitates compatibility with any flash system on the market. This series provides Luer-Lok in and Luer-Lok out flexibility for convenient column stacking. When pre-packed with high-efficiency silica gel (irregular, 25-40 μm, 60 Å; spherical, 20-45 μm, 70 Å), this series presents an outstanding resolution over conventional flash cartridges.

※ Solid, one-piece polypropylene body with thick walls for safety
※ Freely choose irregular silica or spherical silica according to your personal preference
※ Markedly improved resolution and higher sample loading capability
※ Spherical silica provides improved performance without increasing the system backpressure

For spherical silica gel, strict quality controls from raw material to finished product ensures high lot-to-lot reproducibility and tightly controlled specifications.

※Consistency, reliability, reproducibility
※No contamination, lower backpressure 
※Superior resolution
※Symmetrical peaks with no tailing
※Higher sample loading capacity

spherical

UltraPure irregular silica, 40−63 µm, 60 Å (surface area 500 m2 /g, pH 6.5–7.5, loading capacity 0.1–10%)

Item Number Column Size Sample Size(g) Flow Rate(mL/min) Cartridge Length (cm) Cartridge ID (mm) Max. Pressure(psi/bar) Quantity per Box
Small Big
SW-5101-004 4 g 4 mg–0.4 g 15–40 113.8 12.4 400/27.5 24 120
SW-5101-012 12 g 12 mg–1.2 g 30–60 134.8 21.4 400/27.5 24 108
SW-5101-025 25 g 25 mg–2.5 g 30–60 184 21.4 400/27.5 18 72
SW-5101-040 40 g 40 mg–4.0 g 40–70 184.4 26.7 400/27.5 12 48
SW-5101-080 80 g 80 mg–8.0 g 50–100 257.4 31.2 350/24.0 10 20
SW-5101-120 120 g 120 mg–12 g 60–150 261.5 38.6 300/20.7 8 16
SW-5101-220 220 g 220 mg–22 g 80–220 223.5 61.4 300/20.7 4 8
SW-5101-330 330 g 330 mg–33 g 80–220 280.2 61.4 250/17.2 3 6

※ Compatible with all flash chromatography systems on the market.

High-efficiency irregular silica, 25−40 µm, 60 Å (surface area 500 m2 /g, pH 6.5–7.5, loading capacity 0.1–15%)

Item Number Column Size Sample Size(g) Flow Rate(mL/min) Cartridge Length (cm) Cartridge ID (mm) Max. Pressure(psi/bar) Quantity per Box
Small Big
SW-5102-004 4 g 4 mg–0.6 g 15–30 113.8 12.4 400/27.5 24 120
SW-5102-012 12 g 12 mg–1.8 g 25–50 134.8 21.4 400/27.5 24 108
SW-5102-025 25 g 25 mg–3.8 g 25–50 184 21.4 400/27.5 18 72
SW-5102-040 40 g 40 mg–6.0 g 30–60 184.4 26.7 400/27.5 12 48
SW-5102-080 80 g 80 mg–12 g 40–80 257.4 31.2 350/24.0 10 20
SW-5102-120 120 g 120 mg–18 g 45–90 261.5 38.6 300/20.7 8 16
SW-5102-220 220 g 220 mg–33 g 60–120 223.5 61.4 300/20.7 4 8
SW-5102-330 330 g 330 mg–50 g 60–120 280.2 61.4 250/17.2 3 6

※ Compatible with all flash chromatography systems on the market.

UltraPure spherical silica, 40−75 µm, 70 Å (surface area 500 m2 /g, pH 6.0–8.0, loading capacity 0.1–10%)

Item Number Column Size Sample Size(g) Flow Rate(mL/min) Cartridge Length (cm) Cartridge ID (mm) Max. Pressure(psi/bar) Quantity per Box
Small Big
SW-2101-004-SP 4 g 4 mg–0.4 g 15–40 113.8 12.4 400/27.5 24 120
SW-2101-012-SP 12 g 12 mg–1.2 g 30–60 134.8 21.4 400/27.5 24 108
SW-2101-025-SP 25 g 25 mg–2.5 g 30–60 184 21.4 400/27.5 18 72
SW-2101-040-SP 40 g 40 mg–4.0 g 40–70 184.4 26.7 400/27.5 12 48
SW-2101-080-SP 80 g 80 mg–8.0 g 50–100 257.4 31.2 350/24.0 10 20
SW-2101-120-SP 120 g 120 mg–12 g 60–150 261.5 38.6 300/20.7 8 16
SW-2101-220-SP 220 g 220 mg–22 g 80–220 223.5 61.4 300/20.7 4 8
SW-2101-330-SP 330 g 330 mg–33 g 80–220 280.2 61.4 250/17.2 3 6

※Compatible with all flash chromatography systems on the market.

High-efficiency spherical silica, 20−45 µm, 70 Å (surface area 500 m2 /g, pH 6.0–8.0, loading capacity 0.1–15%)

Item Number Column Size Sample Size(g) Flow Rate(mL/min) Cartridge Length (cm) Cartridge ID (mm) Max. Pressure(psi/bar) Quantity per Box
SW-2102-004-SP 4 g 4 mg–0.6 g 15–30 113.8 12.4 400/27.5 24
SW-2102-012-SP 12 g 12 mg–1.8 g 25–50 134.8 21.4 400/27.5 24
SW-2102-025-SP 25 g 25 mg–3.8 g 25–50 184 21.4 400/27.5 18
SW-2102-040-SP 40 g 40 mg–6.0 g 30–60 184.4 26.7 400/27.5 12
SW-2102-080-SP 80 g 80 mg–12 g 40–80 257.4 31.2 350/24.0 10
SW-2102-120-SP 120 g 120 mg–18 g 45–90 261.5 38.6 300/20.7 8
SW-2102-220-SP 220 g 220 mg–33 g 60–120 223.5 61.4 300/20.7 4
SW-2102-330-SP 330 g 330 mg–50 g 60–120 280.2 61.4 250/17.2 3

※Compatible with all flash chromatography systems on the market.

Purification of compounds that are difficult to separate by flash chromatography (ΔRf ≤ 0.2 between spots on TLC) often results in additional steps such as subsequent purification by preparative scale HPLC. It is possible to reduce the amount of additional work required for purification by simply stacking several prepacked SepaFlash™ columns end to end on a flash chromatography system.

In liquid chromatography, chemical species are separated on the basis of their differences in velocity as they move through the column. Increasing column length can significantly increase resolution. By stacking columns end to end the length to diameter (L to D) ratio is increased so that no major changes to the media and solvent system are necessary. Often this increased L to D is sufficient to provide successful separation of difficult mixtures due to close compounds retention time that is not obtained on a single column. The data illustrates the linear relationship between the resolution and overall column length.

HP1
HP

The Highest Purification Performance Available
HP series flash columns are precisely manufactured with high-capacity silica gel, and deliver the highest purification performance. The high-capacity spherical silica has 40% higher surface area, doubling the loading capacity of lower surface area silica.
※ High-capacity silica with 40% more surface area.
※ Higher loading means smaller, faster and cheaper cartridges can be used for any separation.
※ Less solvent required.
※ The highest peak resolution.

High-capacity spherical silica, 25 µm, 50 Å (surface area 700 m2 /g, pH 5.0–8.0, loading capacity 0.1–30%)

Item Number Column Size Sample Size(g) Flow Rate(mL/min) Cartridge Length (cm) Cartridge ID (mm) Max. Pressure(psi/bar) Quantity per Box
Small Big
SW-2102-004-SP(H) 4 g 4 mg–1.2 g 15–30 113.8 12.4 400/27.5 24 120
SW-2102-012-SP(H) 12 g 12 mg–3.6 g 25–50 134.8 21.4 400/27.5 24 108
SW-2102-025-SP(H) 25 g 25 mg–7.5 g 25–50 184 21.4 400/27.5 18 72
SW-2102-040-SP(H) 40 g 40 mg–12 g 30–60 184.4 26.7 400/27.5 12 48
SW-2102-080-SP(H) 80 g 80 mg–24 g 40–80 257.4 31.2 350/24.0 10 20
SW-2102-120-SP(H) 120 g 120 mg–36 g 45–90 261.5 38.6 300/20.7 8 16
SW-2102-220-SP(H) 220 g 220 mg–66 g 60–120 223.5 61.4 300/20.7 4 8
SW-2102-330-SP(H) 330 g 330 mg–99 g 60–120 280.2 61.4 250/17.2 3 6

※ Compatible with all flash chromatography systems on the market.

High-capacity spherical silica, 15 µm, 50 Å (NEW Product) (surface area 700 m2 /g, pH 5.0–8.0, loading capacity 0.1–30%)

Item Number Column Size Sample Size(g) Flow Rate(mL/min) Cartridge Length (cm) Cartridge ID (mm) Max. Pressure(psi/bar) Quantity per Box
Small Big
SW-2103-004-SP(H) 4 g 4 mg–1.2 g 10–15 113.8 12.4 400/27.5 24 120
SW-2103-012-SP(H) 12 g 12 mg–3.6 g 15–20 134.8 21.4 400/27.5 24 108
SW-2103-025-SP(H) 25 g 25 mg–7.5 g 15–20 184 21.4 400/27.5 18 72
SW-2103-040-SP(H) 40 g 40 mg–12 g 20–30 184.4 26.7 400/27.5 12 48
SW-2103-080-SP(H) 80 g 80 mg–24 g 30–40 257.4 31.2 350/24.0 10 20
SW-2103-120-SP(H) 120 g 120 mg–36 g 35–45 261.5 38.6 300/20.7 8 16
SW-2103-220-SP(H) 220 g 220 mg–66 g 50–65 223.5 61.4 300/20.7 4 8
SW-2103-330-SP(H) 330 g 330 mg–99 g 50–65 280.2 61.4 250/17.2 3 6

※ Compatible with all flash chromatography systems on the market.

Double Loading Capacity of SepaFlash™ Cartridges pre-packed with high-capacity silica gel (700 m2 /g for 50 Å pore size) delivers the highest purification performance. The high-capacity 25 µm or 15 µm spherical silica has 40% higher surface area, doubling the loading capacity of lower surface area silica. Santai evaluated the performance of the SepaFlash™ columns compared to two well-known brands. Results show SepaFlash™ outperforms the competitors.

HP3
HP4


Product detail pictures:

factory low price Irregular Silica Flash Column - SepaFlash™ HP Series – Santai detail pictures


Related Product Guide:

Fast and superior quotations, informed advisers to help you choose the correct merchandise that suits all your requirements, a short generation time, responsible quality control and different services for paying and shipping affairs for factory low price Irregular Silica Flash Column - SepaFlash™ HP Series – Santai , The product will supply to all over the world, such as: Brunei, Kuala Lumpur, Madagascar, With the intensified strength and more reliable credit, we are here to serve our customers by providing the highest quality and service, and we sincerely appreciate your support. We will endeavor to maintain our great reputation as the best products supplier in the world. If you have any questions or comments, please contact with us freely.
  • The company has rich resources, advanced machinery, experienced workers and excellent services, hope you keep improving and perfecting your products and service, wish you better!
    5 Stars By Yannick Vergoz from Ghana - 2017.09.09 10:18
    We have been cooperated with this company for many years, the company always ensure timely delivery ,good quality and correct number, we are good partners.
    5 Stars By Victoria from United Arab Emirates - 2017.08.18 11:04
    Write your message here and send it to us