SepaFlash™ E serija
Visokokvalitetni nepravilni silicijum dioksid, 40–63 µm, 60 Å(površine 500 m2/g, pH 6,5–7,5, nosivost 0,1–10%)
Broj artikla | Veličina kolone | Veličina uzorka (g) | Brzina protoka (mL/min) | Dužina kertridža (cm) | ID kertridža (mm) | Max.Pritisak (psi/bar) | Količina po kutiji | |
Mala | Veliki | |||||||
S-8101-0004 | 4 g | 4 mg–0,4 g | 15–40 | 105.8 | 12.4 | 300/20.7 | 36 | 120 |
S-8101-0012 | 12 g | 12 mg–1,2 g | 30–60 | 124.5 | 21.2 | 300/20.7 | 24 | 108 |
S-8101-0025 | 25 g | 25 mg–2,5 g | 30–60 | 172.7 | 21.3 | 300/20.7 | 20 | 80 |
S-8101-0040 | 40 g | 40 mg–4,0 g | 40–70 | 176 | 26.7 | 300/20.7 | 15 | 60 |
S-8101-0080 | 80 g | 80 mg–8,0 g | 50–100 | 248.5 | 30.9 | 200/13.8 | 10 | 20 |
S-8101-0120 | 120 g | 120 mg–12 g | 60–150 | 261.5 | 37.2 | 200/13.8 | 8 | 16 |
S-8101-0220 | 220 g | 220 mg–22 g | 80–220 | 215.9 | 59.4 | 150/10.3 | 4 | 8 |
S-8101-0330 | 330 g | 330 mg–33 g | 80–220 | 280.3 | 59.8 | 150/10.3 | 3 | 6 |
S-8101-0800 | 800 g | 800 mg–80 g | 100–300 | 382.9 | 78.2 | 100/6.9 | 3 | / |
S-8101-1600 | 1600 g | 1,6 g – 160 g | 200–500 | 432.4 | 103.8 | 100/6.9 | 2 | / |
S-8101-3000 | 3000 g | 3,0 g–300 g | 200–500 | 509.5 | 127.5 | 100/6.9 | 1 | / |
※ Kompatibilan sa svim sistemima fleš hromatografije na tržištu.
Visokokvalitetna nepravilna glinica, 50–75 µm, 55 Å
(pH: kiselo 3,8–4,8, neutralno 6,5–7,5, bazno 9,0–10,0; površina 155 m2/g, nosivost 0,1–4%)
Za kiselu glinicu, zamijenite “N” sa “A” u broju stavke, a za bazičnu glinicu sa “B”.
Broj artikla | Veličina kolone | Veličina uzorka (g) | Brzina protoka (mL/min) | Dužina kertridža (cm) | ID kertridža (mm) | Max.Pritisak (psi/bar) | Količina po kutiji | |
Mala | Veliki | |||||||
S-8601-0004-N | 8 g | 8 mg–0,32 g | 10–30 | 105.8 | 12.4 | 300/20.7 | 36 | 120 |
S-8601-0012-N | 24 g | 24 mg–1,0 g | 15–45 | 124.5 | 21.2 | 300/20.7 | 24 | 108 |
S-8601-0025-N | 50 g | 50 mg–2,0 g | 15–45 | 172.7 | 21.3 | 300/20.7 | 20 | 80 |
S-8601-0040-N | 80 g | 80 mg–3,2 g | 20–50 | 176 | 26.7 | 300/20.7 | 15 | 60 |
S-8601-0080-N | 160 g | 160 mg–6,4 g | 30–70 | 248.5 | 30.9 | 200/13.8 | 10 | 20 |
S-8601-0120-N | 240 g | 240 mg–9,6 g | 40–80 | 261.5 | 37.2 | 200/13.8 | 8 | 16 |
S-8601-0220-N | 440 g | 440 mg–17,6 g | 50–120 | 215.9 | 59.4 | 150/10.3 | 4 | 8 |
S-8601-0330-N | 660 g | 660 mg–26,4 g | 50–120 | 280.3 | 59.8 | 150/10.3 | 3 | 6 |
S-8601-0800-N | 1600 g | 1,6 g – 64 g | 100–200 | 382.9 | 78.2 | 100/6.9 | 3 | / |
S-8601-1600-N | 3200 g | 3,2 g – 128 g | 150–300 | 432.4 | 103.8 | 100/6.9 | 2 | / |
S-8601-3000-N | 6000 g | 6,0 g – 240 g | 150–300 | 509.5 | 127.5 | 100/6.9 | 1 | / |
※ Kompatibilan sa svim sistemima fleš hromatografije na tržištu.
- AN002_Pročišćavanje alkalnih jedinjenja pomoću SepaFlash™ aluminijskih patrona
- SepaFlash kolona Katalog EN
Napišite svoju poruku ovdje i pošaljite nam je